Accessibility Information

Users of assistive technologies such as screen readers should use the following link to activate Accessibility Mode before continuing: Learn more and Activate accessibility mode.

Gloveboxes in Process Area of MFFF

Solicitation Number: 10888-R-GMEGLOVEBOX
Agency: Department of Energy
Office: Shaw AREVA MOX Services, LLC (MOX Services)
Location: Shaw AREVA MOX Services, LLC (MOX Services)
  • Print
:
10888-R-GMEGLOVEBOX
:
Sources Sought / Cancelled
:
Added: Jul 24, 2008 5:19 pm
Shaw AREVA MOX Services, LLC (MOX Services), operating under U. S. Department of Energy (DOE) Prime Contract DE-AC02-99CH10888, is the Prime Contractor for the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF) Project to be built at the Savannah River Site (Aiken, South Carolina, USA). Under the Terms and Conditions of the Prime Contract, MOX Services is responsible for the procurement of Supplies, Services, and Construction in support of the MOX Project.



MOX Services is seeking potential vendors for the Manufacturing (Build to Print) of twelve (12) Gloveboxes (GB) situated in process area of the Mixed Oxide (MOX) Fuel Fabrication Facility.

The GME package is made up of the following 12 Gloveboxes:



GME*GB2000 : Handling Glovebox

Design: This Glovebox is made up of 8 small gloveboxes linked by flanges. This GB ensures the transfer of the rods to the different process GBs. Frame type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 50 ft, Width: 15 ft, Height: 2ft

Material: Austenitic Stainless Steel 304L



GME*GB3XXX: Rod filling Line

In the Process Unit, there are 2 identical filing lines: GME *GB3000A and GME*GB3000B.

Each line is made up of the following Gloveboxes:



GME*GB3100: Stack preparation Glovebox

Design: Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 8 ft, Width: 4 ft, Height: 9ft

Material: Austenitic Stainless Steel 304L



GME*GB3200: Tube filling Glovebox

Design: Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 4 ft, Width: 4 ft, Height: 7ft

Material: Austenitic Stainless Steel 304L



GME*GB3300: Cleaning Glovebox

GME*3400: Plugging Glovebox

Design: these 2 GB are in fact one GB with a separation wall Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 10 ft, Width: 4 ft, Height: 7ft

Material: Austenitic Stainless Steel 304L



GME*GB4000: Welding Glovebox

Design: Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 7 ft, Width: 4 ft, Height: 7ft

Material: Austenitic Stainless Steel 304L



GME*GB5XXX: Decontamination Line

This line is made up of 3 Gloveboxes



GME*GB5100: Decontamination Glovebox



GME*GB5300: Non contamination checking Glovebox

Design: These 2 GB are in fact one GB with a separation wall. Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 7 ft, Width: 6 ft, Height: 7ft

Material: Austenitic Stainless Steel 304L



GME*GB5200: Storage Glovebox

Design: Frame Type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 15 ft, Width: 6 ft, Height: 5 ft

Material: Austenitic Stainless Steel 304L



GME*GBXXX Repair Line

This line is made up of 3 Gloveboxes



GME*GB6100: Cutoff Glovebox



GME*GB6200: Cleaning Glovebox

Design: These 2 GB are in fact one GB with a separation wall. Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 7 ft, Width: 6 ft, Height: 7ft

Material: Austenitic Stainless Steel 304L



GME*GB6300: Replugging Glovebox

Design: These 2 GB are in fact one GB with a separation wall. Shell type. Bottom plate 30mm thick, thickness of the shell: 6mm.

Dimension: Length: 7 ft, Width: 6 ft, Height: 7ft





Quality Assurance Program Overview: MOX Quality Level 1 (and designated Level 2) related contracts require supplier commitment to fully meet the MOX Project Quality Assurance Plan commitments and requirements. Examples include:

1. 10 CFR 50, Appendix B, as implemented through ASME NQA-1-1994, as revised by 1995 addenda; and Regulatory Guide 1.28 (Rev. 3)

2. ASNT-TC-1A, 1988 Edition

3. 10 CFR 21- Requirements for “Reporting of Defects and Noncompliance”

4. Commercial Grade dedication process written to an industry recognized standard. (e.g., CGI dedication guidelines, EPRI NP5652).

In addition, these requirements must be “flowed down” to respective sub-tier suppliers.

Added: Jul 31, 2008 10:22 am
This announcement has been placed on hold until further notice.
:
Savannah River Site
P.O. Box 7097
Aiken, South Carolina 29804-7097
:
Shaw AREVA MOX Services, LLC/Savannah River Site
Aiken, South Carolina 29808
United States
:
Hector I. Lopez-De Jesus,
Subcontract Administrator
Phone: 803 819-2329
Fax: 803 819-8931
:
Peter J. Cosgriff,
Senior Subcontract Administrator
Phone: (803) 819-2882
Fax: (803) 819-8931