Comparison of USCOM Cardiac Output and Continuous Thermodilution Cardiac Output
This study has been completed.
First Received: December 5, 2008   Last Updated: December 8, 2008   History of Changes
Sponsored by: Beijing Chao Yang Hospital
Information provided by: Beijing Chao Yang Hospital
ClinicalTrials.gov Identifier: NCT00804778
  Purpose

It's reported that USCOM can be used to measured patients' CO and CI conveniently, accurately and not confined to place, because of it's no aggressive, it's accuracy is doubtful.


Condition
Coronary Artery Disease

MedlinePlus related topics: Coronary Artery Disease
U.S. FDA Resources
Study Type: Observational
Official Title: Comparison of USCOM Cardiac Output and Continuous Thermodilution Cardiac Output in Patients With Coronary Artery Bypass Grafting

Further study details as provided by Beijing Chao Yang Hospital:

Primary Outcome Measures:
  • All 18 post-CABG coronary artery disease patients receiving treatment in the SCCU of Beijing Chaoyang Hospital from March to July 2006 [ Time Frame: The period of monitoring time after CABG was 0.5-6hrs. ] [ Designated as safety issue: Yes ]

Secondary Outcome Measures:
  • All 18 post-CABG coronary artery disease patients receiving treatment in the SCCU of Beijing Chaoyang Hospital from March to July 2006 [ Time Frame: The period of monitoring time after CABG was 0.5-6hrs. ] [ Designated as safety issue: Yes ]

Biospecimen Retention:   None Retained

Biospecimen Description:

Enrollment: 18
Study Start Date: March 2006
Study Completion Date: July 2006
Primary Completion Date: July 2006 (Final data collection date for primary outcome measure)
Groups/Cohorts
CABG,general anesthesia
their CO and CI was measured with USCOM and Swan-ganz cco respectively.
group 1
co measured with swan-ganz cco combined with vigilance

Detailed Description:

18 post-CABG coronary artery disease patients receiving treatment in the SCCU of Beijing Chaoyang Hospital from March to July 2006, male (10) and female (8), with average age of 61.71士10.07 years. Aortic regurgitation or stenosis was ruled out by preoperational color ultrasonic imaging, endocardiac shunt did not exist and there was no heart valve replacement in all the patients. For all the patients after operation, pericardial cavity or left thorax close drainage, small tidal volume (6-8ml/kg) capacity controlled ventilation of breathing machine, appropriate pressure support (10-15cmH2O) and appropriate positive end-expiratory pressure were applied. Intra-aortic balloon pumping (IABP) was not used. Institutional ethics approval was obtained for the conduct of the trial. All the patients received CABG under general anesthesia and non-extracorporeal circulation. Swan-Ganz CCO catheter (mbo 744HF75, USA) was set through right internal jugular vein or right subcalvian vein. The catheters were connected with VIGILANCE monitor after patients went back SCCU and the position of the catheters was adjusted. The bodyweight, height, instant heart rate, central venous pressure, invasive average aortic pressure and pulmonary wedge pressure of the patients were inputted into VIGILANCE monitor. VIGILANCE monitor automatically and intermittently displayed and saved the results of CO, CI, SVR, PVR and other hemodynamic parameters. VIGILANCE determined the hemodynamic parameters every 40-55seconds based on the signal noise ratio.

The period of USCOM monitoring time after CABG was 0.5-6hrs. Lowered the bed head and had the patients in horizontal position during the monitoring.

Monitoring area was AV area. Turned on USCOM, selected AV mode, inputted the sex, height, bodyweight and birth date of the patients. Applied ultra transmission gel on the probe to let the probe contact the skin closely and let the probe point to the gluteal region nearly. USCOM screen automatically displayed the lateral border of the Doppler blood flow curve scanned with flow monitor and speaker displayed the acoustic signal of blood stream. The position, depth and direction of the probe were adjusted based on the figure signals and acoustic signals acquired with USCOM probe. Adjusted the sound volume, wave gain or contrast or turned the patient head gently. It indicated that the sound wave emitted by the probe had passed through aortic valve orifice or the root of aorta and the direction of sound beam paralleled to the blood flow through the aorta valve orifice when USCOM screen displayed maximum Doppler blood velocity wave and speaker displayed sharp and strong blood acoustic signals. The results were frozen and saved . Optimal measuring site, depth the probe was depressed down and direction of the probe were marked for the next measurement. Continuous 3-5 Doppler flow curves and the CO and CI measured on them were taken each time. The flow curves of one respiratory circle were taken for atrial fibrillation patients. For round probe, plane diameter was 1.5cm and frequency was 3.3MHz. The probe was disinfected with Iodophors each time before and after the measurement. The data of patient height, bodyweight and age, and operation duration was acquired from anesthesia note. CO time intervals measured with the two methods were about 2min. There was at least 30min interval between each pair of CO. Three to four pairs of CO and CI data were taken for each patient.

  Eligibility

Ages Eligible for Study:   42 Years to 78 Years
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   No
Sampling Method:   Probability Sample
Study Population

18 post-CABG coronary artery disease patients receiving treatment in the SCCU of Beijing Chaoyang Hospital from March to July 2006, male (10) and female (8), with average age of 61.71士10.07 years.For all the patients after operation, pericardial cavity or left thorax close drainage, small tidal volume (6-8ml/kg) capacity controlled ventilation of breathing machine, appropriate pressure support (10-15cmH2O) and appropriate positive end-expiratory pressure were applied. Institutional ethics approval was obtained for the conduct of the trial.

Criteria

Inclusion Criteria:

  • All 18 post-CABG coronary artery disease patients receiving treatment in the SCCU of Beijing Chaoyang Hospital from March to July 2006, male (10) and female (8), with average age of 61.71士10.07 years.

Exclusion Criteria:

  • Aortic regurgitation or stenosis was ruled out by preoperational color ultrasonic imaging, endocardiac shunt did not exist and there was no heart valve replacement in all the patients.
  • Intra-aortic balloon pumping (IABP) was not used.
  Contacts and Locations
Please refer to this study by its ClinicalTrials.gov identifier: NCT00804778

Locations
China
society of emergency medicine of C.M.A
beijing, China, 100020
society of emergency medicine of C.M.A
beijing, China, 100020
Sponsors and Collaborators
Beijing Chao Yang Hospital
Investigators
Principal Investigator: chunsheng li, professor society of emergency medicine of C.M.A
  More Information

Additional Information:
Publications:
Responsible Party: society of emergency medicine of C.M.A ( department of emergency,beijing chaoyang hospital )
Study ID Numbers: chumingyidoc@sohu.com, lcscyyy@sohu.com
Study First Received: December 5, 2008
Last Updated: December 8, 2008
ClinicalTrials.gov Identifier: NCT00804778     History of Changes
Health Authority: China: Ethics Committee;   United States: Institutional Review Board

Keywords provided by Beijing Chao Yang Hospital:
CABG
CAD
CI
CO
thermodilution
USCOM

Study placed in the following topic categories:
Arterial Occlusive Diseases
Coronary Disease
Heart Diseases
Myocardial Ischemia
Vascular Diseases
Arteriosclerosis
Ischemia
Coronary Artery Disease

Additional relevant MeSH terms:
Arterial Occlusive Diseases
Coronary Disease
Heart Diseases
Myocardial Ischemia
Vascular Diseases
Cardiovascular Diseases
Arteriosclerosis
Coronary Artery Disease

ClinicalTrials.gov processed this record on March 16, 2009