LMER Fiber 12-Gallon Drum Specification

Print Checklist in PDF format

Description Stores Catalog
Number
Packaging Filling
Instructions
Plant
Drum, Fiber, open head, 12 gallon, 15 1/2 in. ID x 14 3/4
UN 1G/Y 75/S, 700 lb. sidewall, Natural  Kraft
02-113-5738 LMTPM-CHK-38 Y-12

    Mfg. Details Per:   LMER Packaging Specifications
                                No. 200-1G0-0002
                                Issue Date:         April 15, 1994
                                Revised Date:     June 15, 1999

The following inspections will be performed on the incoming drums by receiver to determine the drums meet quality standards and the requirements of this document. However, the receiver is not limited to the following inspections to determine quality and specification conformance. Conformance will be indicated by a Y or N in the "Y/N" column, and negative responses documented on the Nonconformance Report (NCR), UCN 11457, (items 3-21b), attached to the checklist, and submitted to Lockheed Martin Transportation and Packaging Management (LMTPM) for necessary action.

This checklist is to be reproduced for QC Inspections.

Receiver Inspection Quality Control (QC) Checklist for Incoming Fiber Drums

 

QC Conformance

Y/N

<< "No's" to be documented on form UCN-11457, with checklist

1

Drum condition   Drums in good physical condition; are dry, no physical damage.

2

Capacity   Drum is capacity specified in Order/Catalog Description (marked on drum side).

3

Fiberboard Surface   Clean, no significant scuffing, breaks or cuts in exterior surface, nor interior surface of the drum. Exterior has protective coating.

4

Locking rings, chimes   Lever locking rings, and metal chimes are painted or varnished and show no significant rusting /corrosion.
  Lever locking rings close tightly; not loose around drum lid.

5

Drum lids   Lids are varnished, and show no significant rusting/corrosion.

6

Markings

(on side)

  Drums marked (as a minimum) with LMER specified UN markings, per Catalog Description.
  Drums legibly marked (printed) in accordance with required 49 CFR UN markings, and specified gross test weight, below top chime.
  CATN--plus the last four (4) digits of catalog number, below UN markings per
¶ 5.0.
Catalog Number___________________________ P. O. Number________________________________
Total Units Received_______________________ Inspection Method: Per LMTPM QC Inspection Plan
Sample Size_______[Based on ANSI/ASQC Z1.4-1993] NCR No._______________________
Inspector/Date_________________________________

Additional comments on back: _____check, if yes.

The above QC inspection check list shall be accomplished for each order based on random samples of incoming carbon steel drums, by LMER facilities to determine manufacturer's conformance to these specified LMER Packaging Specifications.

Shipments of carbon steel drums not meeting specified requirements will be returned to the seller for credit.

QC inspections resulting in non-compliance with these Packaging Specifications will be cause for rejection of the entire shipment.

 

[TPM Home] [ORNL Home] [Disclaimer] [Website Comments] [Contact Us]

Web site maintained by Oak Ridge National Laboratory, one of the U.S. Department of Energy's
multiprogram national research and development facilities, managed by UT-Battelle, LLC