SUBENT 30322001 940927 20050616 20050926 0000 BIB 18 63 TITLE CROSS-SECTIONS OF 14 MEV NEUTRON REACTIONS PRODUCING SHORT-LIVED NUCLIDES. AUTHOR (J.JANCZYSZYN,L.GORSKI) INSTITUTE (3POLITJ) REFERENCE (J,JRC,14,201,73) (J,CA,17,(3),703,72)EXP.DETAIL. (J,RRL,8,363,7112) BRIEF DESCRIPTION OF EXPERIMENT. MONITOR (29-CU-63(N,2N)29-CU-62,,SIG) NEUTRON FLUX WAS DETERMINED ON THE BASIS OF THE 'TEXAS CONVENTION',R.L.HEATH,PROC.INTERN.CONF.MODERN TRENDS IN ACTIVATION ANALYSIS,COLLEGE STATION,TEXAS,1965,P.389. *SPECIFICATION OF TEXAS CONVENTION, THE EFFECTIVE FLUXES FOR SAMPLE ACTIVATIONS ARE TO BE MEASURED BY EXPOSING HIGH-PURITY COPPER DISKS OF 0.25- MM THICKNESS AND 1-CM AND/OR 2.5-CM DIA FOR 1 MIN TO THE N-FLUX TO BE MEASURED. ----AND THE DISINTEGRATION RATE OF CU-62 ACTIVITY IS DETERMINED. THEN THE FLUX IS GIVEN IN DISINT./MIN/(GRAM OF COPPER). FACILITY (CCW) NEUTRON GENERATOR. IN ORDER TO OBTAIN THE IRRADI- ATION TIMES 0.1 TO 1 SEC. A DEFLECTING ELECTRODE WAS PLACED IN THE GENERATOR TUBE. INC-SOURCE (D-T) T(D,N)HE REACTION. INC-SPECT 14 MEV NEUTRONS, FLUX WAS 5.E+7 TO 2.E+8 N/CM2/SEC. METHOD (ACTIV) CYCLIC NEUTRON ACTIVATION METHOD WITH THE 0.2- SECOND FAST PNEUMATIC TUBE SYSTEM (MEAN VELOCITY,30M/S) EACH SAMPLE WAS IRRADIATED FOR 3 HALF-LIVES OF THE INVESTIGATED NUCLIDE. AND THE COUNTING TIME WAS EQUAL TO THE IRRADIATION,UNLESS THE SHORTENING OF THE FORMER WAS NECESSARY TO AVOID THE 'LONG-LIVED' NUCLIDE DECAY. AFTER A PAUSE OF 5 TO 10 HALF-LIVES OF NUCLIDE, A 2ND MEASUREMENT WITH THE SAME COUNTING TIME AS THE 1ST ONE WAS FOLLOWED. DETECTOR (NAICR) NAI(TL) 3 * 3INCH, WITH A 400-CHANNEL ANALYSER VICTOREEN ST 400 DM. (SCIN) SCINTILLATION COUNTER, HORNYAK NE 450, WITH A PHOTOMULTILIER EMI6097F FOR NEUTRON MONITORING. PART-DET (DG,B+) DECAY GAMMAS OR DECAY BETA+. CORRECTION THE DEAD TIME OF THE MULTICHANNEL ANALYSER WAS CORRECT- ED. ANALYSIS WHEN THE SAME ISOMER ARISES FROM TWO DIFFERENT ISTOPES OF THE SAME ELEMENTS AS A RESULT OF THE (N,N') AND (N,2N) REACTIONS, THE WEIGHED MEAN CROSS-SECTION WAS CALCULATED, TAKING ISOTOPIC ABUNDANCES AS WEIGHTS. HALF-LIFE MAINLY TAKEN FROM THE TABLE OF ISOTOPES,LEDERER ET AL., 6TH ED.,1967. ERR-ANALYS TOTAL ERROR IS GIVEN. THE LARGE ERRORS FOR SOME OF CROSS-SECTIONS MAY PARTIALLY BE DUE TO INSTRUMENTAL IMPERFECTIONS AND TO THE FACT THAT THE CROSS-SECTION WAS NOT THE MAIN PURPOSE OF THIS FACILITY OF AUTOMATIC ACTIVATION ANALYSIS. COMMENT IN A FEW CASES THE CONVERSION COEFFICIENT IS NOT KNOWN, AND IS ASSUMED TO BE 0 WITH THE NUMBER OF QUANTA PER DISINTEGRATION TO BE 1. STATUS FROM TABLE 1 OF J.RADIOANAL.CHEM.,14(1973)201. (APRVD) APPROVED BY JANCZYCZYN WITH NOTES, 29/04/76. HISTORY (760203C) KO. (760519A) KO. -ADD 'APRVD',INF.ON HALF-LIFE OF IN-114M2 AND AUTHOR'S CORRECTION OF CE-140(N,2N) X-SECTION.- (900130A)VOF.-ISO-QUANT CHANGED TO REACTION FORMALISM STANDARD CHANGED TO MONITOR FORMALISM RESID-NUC DELETED. (930224U) HW.-MISPUNCH IN BIB SECTION CORRECTED.- (940705U) HW.-REACTION CODE ALTERED IN SAN 021.- ENDBIB 63 COMMON 1 3 EN MEV 14. ENDCOMMON 3 ENDSUBENT 70 SUBENT 30322017 900212 20050616 20050926 0000 BIB 2 2 REACTION (74-W-0(N,X)74-W-183-M,,SIG) HALF-LIFE (HL,74-W-183-M1) = 5.3 SEC. ENDBIB 2 NOCOMMON 0 0 DATA 3 1 DATA DATA-ERR HL MB MB SEC 520. 130. 5.3 ENDDATA 3 ENDSUBENT 10