BFRL ICON Strength and Ductility of Concrete Beams Reinforced With Carbon FRP and Steel.


pdf icon Strength and Ductility of Concrete Beams Reinforced With Carbon FRP and Steel. (1019 K)
Duthinh, D.; Starnes, M. A.

NISTIR 6830; 33 p. November 2001.

Available from:

National Technical Information Service (NTIS), Technology Administration, U.S. Department of Commerce, Springfield, VA 22161.
Telephone: 1-800-553-6847 or 703-605-6000;
Fax: 703-605-6900; Rush Service (Telephone Orders Only) 800-553-6847;
Website: http://www.ntis.gov
Order number: PB2002-101196

Keywords:

concrete beams; carbon; steels; anchorage; beams; carbon fiber-reinforced polymers; ductility; flexure strength; reinforced concretes; repair; strengthening

Abstract:

Seven concrete beams reinforced internally with steel and externally with carbon fiber-reinforced polymers (FRP) applied after the concrete had cracked were tested under four-point bending. Results show that FRP is very effective for flexural strengthening. As the amount of steel increases, the additional strength provided by the carbon decreases. Compared to a beam reinforced heavily with steel only, beams reinforced with both steel and carbon have adequate deformation capacity, in spite of their brittle mode of failure. Clamping or wrapping of the ends of the laminate enhances the capacity of adhesively bonded FRP anchorage. Design equations for anchorage, allowable stress, ductility, and amount of reinforcement are discussed.



Building and Fire Research Laboratory
National Institute of Standards and Technology
Gaithersburg, MD 20899