Equipment Logistics Services
41 12B NIM/LEM Out register
ELS Home | PREP | Useful Links | Vendors List
Return to Jorway Directory | Return to Pool Catalog | ||||||||||||||||||||||
GENERAL DESCRIPTION | ||||||||||||||||||||||
The Model 41 12 bit Output Register is a single width Camac compatable module that meets the requirements of EUR4100e. The Model 41 provides up to 12 bits of information to be extracted from the Dataway Write lines. This information is stored and is available at the front panel as fast N.I.M. level signals, or optionally stored as power drivers. A versitile system of updating the storage registers is offered to provide flexibility of use. Data can be strobed into storage from write lines by function command F16 or F17. On command, F16 data is strobed in at S1 providing D.C. outputs. When pulsed outputs are required, function F17 is used. In response to F17-S1 data will be strobed into storage; at S2, however, all bits in the register will be reset to zero. Each time the register is updated a strobe output signal is generated. In response to F16-S1 it is a 3 usec. pulse. The strobe signal generated in response to F1 7-S1 will last from time S1 to S2, as do the data outputs. In addition to these modes of operation the register may also be selectively set and reset. In this mode the Da taway Write lines are used as enable lines which select the bits that are to respond to the function requested. Function F20 will set to "1" any bit that has its write input at a logic "1 Function F22 will reset to "O" any bit that has its write input at a logic "1 Both F20 and F22 use strobe S1 to perform the operation. An N light is provided to visually indicate when the module is addressed. |
||||||||||||||||||||||
MODEL 41 SPECIFICATIONS | ||||||||||||||||||||||
OUTPUTS: DATA and STROBE Fast N.I.M. outputs, current source Logic "0" I out = 0 Logic "1" I out = -14ma min. Max. output voltage -2v Pulse Width: In response to F16, D.C. Level output In response to F 17, P.W. is time from S1 to S2. Option 1. Voltage Outputs, Open Collector Logic "O" +100v max. Logic "1 " +.5v max. Max. power out 250 mw DATAWAY COMMANDS (all fully decoded)
DATAWAY CONTROLS
| ||||||||||||||||||||||
For assistance contact helpdesk@fnal.gov. Information maintained by Mike Behnke; last modified on July 11, 2006. (Address comments about page to prep-webmaster@fnal.gov.) |