Guardwall Criteria Files...
Criteria File |
Description
|
c_gwall2s.x10 |
FLH metric standard precast concrete guardwall
(618M) and stone masonry
guardwall (620M).
Guardwall, guardwall footing, backfill and foreslope behind
wall.
Uses station ranges specified in exceptions data file to locate
guardwall. |
c_gwall3d.x10 |
Guardwall, guardwall footing, backfill and foreslope
behind wall.
Uses lines drawn in plan view dgn file to locate guardwall.
Closes off base course layers with vertical lines at inside
face wall if necessary. |
c_gwall3s.x10 |
Guardwall, guardwall footing, backfill and foreslope
behind wall.
Uses station ranges specified in exceptions data file to locate
guardwall.
Closes off base course layers with vertical lines at inside
face wall if necessary. |
c_gwall2s.x10
- Description:
- FLH metric standard precast concrete guardwall (M618)
and FLH metric standard stone masonry guardwall (M620).
Draws simple guardwall with footing plus backfill and foreslope
behind guardwall.
Uses station ranges specified in the exceptions data file
to locate guardwall.
|
define
variables that must be assigned values in the input data
file:
- "type 2 guardwall backfill width"
- "type 2 guardwall base course depth"
- "type 2 guardwall footing thickness"
- "type 2 guardwall footing width"
- "type 2 guardwall foreslope" (e.g., -1:2)
- "type 2 guardwall height"
- "type 2 guardwall thickness"
define_dgn
variables that must be assigned values in the input data
file:
Variables that must be defined in exceptions
data file:
- _d_use_type2_guardwall_lt (set = 1 to toggle on
guardwall)
- _d_use_type2_guardwall_rt
Notes for c_gwall2s.x10:
- This criteria was written to match the FLH metric standard
precast concrete guardwall (M618) and FLH metric standard
stone masonry guardwall (M620) dimensions. Default values
for all the variables have been set in the criteria file
to match the dimensions on the standard drawings. If the
default values shown below are acceptable, then they don't
have to be defined in the input file.
- "type 2 guardwall backfill width" = 0.600
- "type 2 guardwall base course depth" = 0.150
- "type 2 guardwall footing thickness" = 0.300
- "type 2 guardwall footing width" = 1.050
- "type 2 guardwall foreslope" = -1:2
- "type 2 guardwall height" = 0.685
- "type 2 guardwall thickness" = 0.600
- Combines the functionality of a simple guardwall criteria
with the functionality of the foreslope criteria. This criteria
is written so that it overrides the foreslope used for the
typical section (e.g., fh_fs5.x10)
- Station ranges for the guardwall are set in the exceptions
data file using the _d_use_type2_guardwall_lt and _d_use_type2_guardwall_rt
variable and the following syntax:
if sta >= 1+000 r 1 and sta <= 2+000 r 1 then
{
_d_use_type2_guardwall_lt = 1
}
- This criteria (c_gwall2s.x10) and c_gwall2d.x10 draw
basically the same elements. The only differences between
the two criteria files are as follows:
- c_gwall2d.x10 uses lines drawn in a plan view dgn
file to specify the station ranges for guardwall; c_gwall2s.x10
uses station ranges explicitly specified in the exceptions
data file
- c_gwall2d.x10 widens the pavement structural section
as necessary to locate the inside face of the guardwall
at the offset from centerline represented by the lines
drawn in plan view dgn file; c_gwall2s.x10 will never
widen the pavement structural section
- Must be included immediately before the foreslope criteria
(fh_fs[1-5].x10) in the input file.
- All pavement structure undercut layers are terminated
at the inside face of the guardwall. If necessary they are
closed off with vertical lines.
- This criteria has no built-in provision for widening
the pavement structural section -- it places the inside
toe of the guardwall footing at whatever offset from centerline
where the preceding criteria left off. Criteria file c_gwall2d.x10
will do widening in addition to what this criteria file
does.
- Level/symbology of cross-section elements drawn by this
criteria is set up so that a separate quantity for guardwall
backfill can be calculated in the earthwork procedure. (Proposed
undercut, soil type = guardwall_backfill, lv=17, co=18)
- Slope stake report will work correctly with the elements
drawn by this criteria if you include lv=17 co=18 in the
finish grade level/symbology. This is due to the "always
take the lowest level" rule written into the slope stakes
search routine.
- fh_ss3.x10 is "included" in this criteria, and fh_fs[1-5].x10
is toggled off using the _d_stop_at_approach_road variable.
|
c_gwall3d.x10
- Description:
- Draws simple guardwall with footing plus backfill and
foreslope behind guardwall.
Uses lines drawn in plan view dgn file to locate guardwall.
Widens pavement structural section as necessary to
locate inside face of guardwall at offset from centerline
of line drawn in plan view.
|
define
variables that must be assigned values in the input data
file:
- "type 3 guardwall distance to hinge"
- "type 3 guardwall footing thickness"
- "type 3 guardwall footing width"
- "type 3 guardwall foreslope" (e.g., -1:2)
- "type 3 guardwall overall height"
- "type 3 guardwall reveal height"
- "type 3 guardwall thickness"
define_dgn
variables that must be assigned values in the input data
file:
- "type 3 guardwall in dgn"
Variables that must be defined in exceptions
data file:
Notes for c_gwall3d.x10:
- This criteria was originally written to match a standard
detail for the Chalone Creek project. Default values for
all the variables have been set in the criteria file to
match the original detail. If the default values shown below
are acceptable, then they don't have to be defined in the
input file.
- "type 3 guardwall distance to hinge" = 0.600
- "type 3 guardwall footing thickess" = 0.150
- "type 3 guardwall footing width" = 1.000
- "type 3 guardwall foreslope" = -1:1.5
- "type 3 guardwall overall height" = 1.090
- "type 3 guardwall reveal height" = 0.740
- "type 3 guardwall thickness" = 0.455
- Combines the functionality of a simple guardwall criteria
with the functionality a widening criteria and a foreslope
criteria. This criteria is written so that it overrides
the foreslope used for the typical section (e.g., fh_fs5.x10)
- Station ranges for the guardwall are set by drawing lines
in a plan view dgn file. These lines are also used to locate
the offset of the inside face of the guardwall from centerline;
the pavement structural section is widened as necessary
to locate the guardwall at this offset.
- This criteria (c_gwall3d.x10) and c_gwall3s.x10 draw
basically the same elements. The only differences between
the two criteria files are as follows:
- c_gwall3d.x10 uses lines drawn in a plan view dgn
file to specify the station ranges for guardwall; c_gwall3s.x10
uses station ranges explicitly specified in the exceptions
data file
- c_gwall3d.x10 widens the pavement structural section
as necessary to locate the inside face of the guardwall
at the offset from centerline represented by the lines
drawn in plan view dgn file; c_gwall3s.x10 will never
widen the pavement structural section
- Must be included immediately before the foreslope criteria
(fh_fs[1-5].x10) in the input file.
- Pavement undercut layers that are lower than the guardwall
footing are tied off with vertical lines at the inside face
of the guardwall, as shown above.
- Level/symbology of cross-section elements drawn by this
criteria is set up so that a separate quantity for guardwall
backfill can be calculated in the earthwork procedure. (Proposed
undercut, soil type = guardwall_backfill, lv=17, co=18)
- Slope stake report will work correctly with the elements
drawn by this criteria if you include lv=17 co=18 in the
finish grade level/symbology. This is due to the "always
take the lowest level" rule written into the slope stakes
search routine.
- fh_ss3.x10 is "included" in this criteria, and fh_fs[1-5].x10
is toggled off using the _d_stop_at_approach_road variable.
|
c_gwall3s.x10
- Description:
- Draws simple guardwall with footing plus backfill and
foreslope behind guardwall.
Uses station ranges specified in the exceptions data file
to locate guardwall.
|
define
variables that must be assigned values in the input data
file:
- "type 3 guardwall distance to hinge"
- "type 3 guardwall footing thickness"
- "type 3 guardwall footing width"
- "type 3 guardwall foreslope" (e.g., -1:2)
- "type 3 guardwall overall height"
- "type 3 guardwall reveal height"
- "type 3 guardwall thickness"
define_dgn
variables that must be assigned values in the input data
file:
Variables that must be defined in exceptions
data file:
- _d_use_type3_guardwall_lt (set = 1 to toggle on
guardwall)
- _d_use_type3_guardwall_rt
Notes for c_gwall3s.x10:
- This criteria was originally written to match a standard
detail for the Chalone Creek project. Default values for
all the variables have been set in the criteria file to
match the original detail. If the default values shown below
are acceptable, then they don't have to be defined in the
input file.
- "type 3 guardwall distance to hinge" = 0.600
- "type 3 guardwall footing thickess" = 0.150
- "type 3 guardwall footing width" = 1.000
- "type 3 guardwall foreslope" = -1:1.5
- "type 3 guardwall overall height" = 1.090
- "type 3 guardwall reveal height" = 0.740
- "type 3 guardwall thickness" = 0.455
- Combines the functionality of a simple guardwall criteria
with the functionality of the foreslope criteria. This criteria
is written so that it overrides the foreslope used for the
typical section (e.g., fh_fs5.x10)
- Station ranges for the guardwall are set in the exceptions
data file using the _d_use_type3_guardwall_lt and _d_use_type3_guardwall_rt
variable and the following syntax:
if sta >= 1+000 r 1 and sta <= 2+000 r 1 then
{
_d_use_type3_guardwall_lt = 1
}
- This criteria (c_gwall3s.x10) and c_gwall3d.x10 draw
basically the same elements. The only differences between
the two criteria files are as follows:
- c_gwall3d.x10 uses lines drawn in a plan view dgn
file to specify the station ranges for guardwall; c_gwall3s.x10
uses station ranges explicitly specified in the exceptions
data file
- c_gwall3d.x10 widens the pavement structural section
as necessary to locate the inside face of the guardwall
at the offset from centerline represented by the lines
drawn in plan view dgn file; c_gwall3s.x10 will never
widen the pavement structural section
- Must be included immediately before the foreslope criteria
(fh_fs[1-5].x10) in the input file.
- Pavement undercut layers that are lower than the guardwall
footing are tied off with vertical lines at the inside face
of the guardwall, as shown above.
- This criteria has no built-in provision for widening
the pavement structural section -- it places the inside
face of the guardwall at the offset from centerline where
the preceding criteria left off. Criteria file c_gwall3d.x10
will do widening in addition to what this criteria file
does.
- Level/symbology of cross-section elements drawn by this
criteria is set up so that a separate quantity for guardwall
backfill can be calculated in the earthwork procedure. (Proposed
undercut, soil type = guardwall_backfill, lv=17, co=18)
- Slope stake report will work correctly with the elements
drawn by this criteria if you include lv=17 co=18 in the
finish grade level/symbology. This is due to the "always
take the lowest level" rule written into the slope stakes
search routine.
- fh_ss3.x10 is "included" in this criteria, and fh_fs[1-5].x10
is toggled off using the _d_stop_at_approach_road variable.
|
|
|