[Code of Federal Regulations]
[Title 29, Volume 5]
[Revised as of January 1, 2007]
From the U.S. Government Printing Office via GPO Access
[CITE: 29CFR1910.27]

[Page 125-130]
 
                             TITLE 29--LABOR
 
CHAPTER XVII--OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT 
                                OF LABOR
 
PART 1910_OCCUPATIONAL SAFETY AND HEALTH STANDARDS--Table of Contents
 
                   Subpart D_Walking-Working Surfaces
 
Sec.  1910.27  Fixed ladders.

    (a) Design requirements--(1) Design considerations. All ladders, 
appurtenances, and fastenings shall be designed to meet the following 
load requirements:
    (i) The minimum design live load shall be a single concentrated load 
of 200 pounds.
    (ii) The number and position of additional concentrated live-load 
units of 200 pounds each as determined from anticipated usage of the 
ladder shall be considered in the design.
    (iii) The live loads imposed by persons occupying the ladder shall 
be considered to be concentrated at such points as will cause the 
maximum stress in the structural member being considered.
    (iv) The weight of the ladder and attached appurtenances together 
with the live load shall be considered in the design of rails and 
fastenings.
    (2) Design stresses. Design stresses for wood components of ladders 
shall not exceed those specified in Sec.  1910.25. All wood parts of 
fixed ladders shall meet the requirements of Sec.  1910.25(b).

For fixed ladders consisting of wood side rails and wood rungs or 
cleats, used at a pitch in the range 75 degrees to 90 degrees, and 
intended for use by no more than one person per section, single ladders 
as described in Sec.  1910.25(c)(3)(ii) are acceptable.
    (b) Specific features--(1) Rungs and cleats. (i) All rungs shall 
have a minimum diameter of three-fourths inch for metal ladders, except 
as covered in paragraph (b)(7)(i) of this section and a minimum diameter 
of 1\1/8\ inches for wood ladders.
    (ii) The distance between rungs, cleats, and steps shall not exceed 
12 inches and shall be uniform throughout the length of the ladder.
    (iii) The minimum clear length of rungs or cleats shall be 16 
inches.
    (iv) Rungs, cleats, and steps shall be free of splinters, sharp 
edges, burrs, or projections which may be a hazard.
    (v) The rungs of an individual-rung ladder shall be so designed that 
the foot cannot slide off the end. A suggested design is shown in figure 
D-1.
[GRAPHIC] [TIFF OMITTED] TC27OC91.001

   Figure D-1--Suggested Design for Rungs on Individual-rung Ladders.
    (2) Side rails. Side rails which might be used as a climbing aid 
shall be of such cross sections as to afford adequate gripping surface 
without sharp edges, splinters, or burrs.
    (3) Fastenings. Fastenings shall be an integral part of fixed ladder 
design.
    (4) Splices. All splices made by whatever means shall meet design 
requirements as noted in paragraph (a) of this section. All splices and 
connections shall have smooth transition with original members and with 
no sharp or extensive projections.
    (5) Electrolytic action. Adequate means shall be employed to protect 
dissimilar metals from electrolytic action when such metals are joined.
    (6) Welding. All welding shall be in accordance with the ``Code for 
Welding in Building Construction'' (AWSD1.0-1966).
    (7) Protection from deterioration. (i) Metal ladders and 
appurtenances shall be painted or otherwise treated to resist corrosion 
and rusting when location demands. Ladders formed by individual metal 
rungs imbedded in concrete, which serve as access to pits and to other 
areas under floors, are frequently located in an atmosphere that causes 
corrosion and rusting. To increase rung life in such atmosphere, 
individual metal rungs shall have a minimum diameter of 1 inch or shall 
be

[[Page 126]]

painted or otherwise treated to resist corrosion and rusting.
    (ii) Wood ladders, when used under conditions where decay may occur, 
shall be treated with a nonirritating preservative, and the details 
shall be such as to prevent or minimize the accumulation of water on 
wood parts.
    (iii) When different types of materials are used in the construction 
of a ladder, the materials used shall be so treated as to have no 
deleterious effect one upon the other.
[GRAPHIC] [TIFF OMITTED] TC27OC91.002

   Figure D-2--Rail Ladder With Bar Steel Rails and Round Steel Rungs
    (c) Clearance--(1) Climbing side. On fixed ladders, the 
perpendicular distance from the centerline of the rungs to the nearest 
permanent object on the climbing side of the ladder shall be 36 inches 
for a pitch of 76 degrees, and 30 inches for a pitch of 90 degrees (fig. 
D-2 of this section), with minimum clearances for intermediate pitches 
varying between these two limits in proportion to the slope, except as 
provided in subparagraphs (3) and (5) of this paragraph.
    (2) Ladders without cages or wells. A clear width of at least 15 
inches shall be provided each way from the centerline of the ladder in 
the climbing space, except when cages or wells are necessary.
    (3) Ladders with cages or baskets. Ladders equipped with cage or 
basket are excepted from the provisions of subparagraphs (1) and (2) of 
this paragraph, but shall conform to the provisions of paragraph 
(d)(1)(v) of this section. Fixed ladders in smooth-walled wells are 
excepted from the provisions of subparagraph (1) of this paragraph, but 
shall conform to the provisions of paragraph (d)(1)(vi) of this section.
    (4) Clearance in back of ladder. The distance from the centerline of 
rungs, cleats, or steps to the nearest permanent object in back of the 
ladder shall be not less than 7 inches, except that when unavoidable 
obstructions are encountered, minimum clearances as shown in figure D-3 
shall be provided.
                        Minimum Ladder Clearances
[GRAPHIC] [TIFF OMITTED] TC27OC91.003

   Figure D-3--Clearance for Unavoidable Obstruction at Rear of Fixed 
                                 Ladder
    (5) Clearance in back of grab bar. The distance from the centerline 
of the grab bar to the nearest permanent object in back of the grab bars 
shall be not less than 4 inches. Grab bars shall not protrude on the 
climbing side beyond the rungs of the ladder which they serve.
    (6) Step-across distance. The step-across distance from the nearest 
edge of ladder to the nearest edge of equipment or structure shall be 
not more

[[Page 127]]

than 12 inches, or less than 2\1/2\ inches (fig. D-4).
[GRAPHIC] [TIFF OMITTED] TC27OC91.004

                    Figure D-4--Ladder Far from Wall
    (7) Hatch cover. Counterweighted hatch covers shall open a minimum 
of 60 degrees from the horizontal. The distance from the centerline of 
rungs or cleats to the edge of the hatch opening on the climbing side 
shall be not less than 24 inches for offset wells or 30 inches for 
straight wells. There shall be not protruding potential hazards within 
24 inches of the centerline of rungs or cleats; any such hazards within 
30 inches of the centerline of the rungs or cleats shall be fitted with 
deflector plates placed at an angle of 60 degrees from the horizontal as 
indicated in figure D-5. The relationship of a fixed ladder to an 
acceptable counterweighted hatch cover is illustrated in figure D-6.
    (d) Special requirements--(1) Cages or wells. (i) Cages or wells 
(except on chimney ladders) shall be built, as shown on the applicable 
drawings, covered in detail in figures D-7, D-8, and D-9, or of 
equivalent construction.
    (ii) Cages or wells (except as provided in subparagraph (5) of this 
paragraph) conforming to the dimensions shown in figures D-7, D-8, and 
D-9 shall be provided on ladders of more than 20 feet to a maximum 
unbroken length of 30 feet.
[GRAPHIC] [TIFF OMITTED] TC27OC91.005

              Figure D-5--Deflector Plates for Head Hazards
[GRAPHIC] [TIFF OMITTED] TC27OC91.006

     Figure D-6--Relationship of Fixed Ladder to a Safe Access Hatch
    (iii) Cages shall extend a minimum of 42 inches above the top of 
landing, unless other acceptable protection is provided.
    (iv) Cages shall extend down the ladder to a point not less than 7 
feet nor more than 8 feet above the base of the ladder, with bottom 
flared not less than 4 inches, or portion of cage opposite ladder shall 
be carried to the base.
    (v) Cages shall not extend less than 27 nor more than 28 inches from 
the centerline of the rungs of the ladder. Cage shall not be less than 
27 inches in width. The inside shall be clear of projections. Vertical 
bars shall be located at a maximum spacing of 40 degrees around the 
circumference of the cage; this will give a maximum spacing of 
approximately 9\1/2\ inches, center to center.
    (vi) Ladder wells shall have a clear width of at least 15 inches 
measured each way from the centerline of the ladder. Smooth-walled wells 
shall be a

[[Page 128]]

minimum of 27 inches from the centerline of rungs to the well wall on 
the climbing side of the ladder. Where other obstructions on the 
climbing side of the ladder exist, there shall be a minimum of 30 inches 
from the centerline of the rungs.
[GRAPHIC] [TIFF OMITTED] TC27OC91.007

          Figure D-7--Cages for Ladders More Than 20 Feet High
[GRAPHIC] [TIFF OMITTED] TC27OC91.008

         Figure D-8--Clearance Diagram for Fixed Ladder in Well

[[Page 129]]

[GRAPHIC] [TIFF OMITTED] TC27OC91.009

                Figure D-9--Cages--Special applications.
    (2) Landing platforms. When ladders are used to ascend to heights 
exceeding 20 feet (except on chimneys), landing platforms shall be 
provided for each 30 feet of height or fraction thereof, except that, 
where no cage, well, or ladder safety device is provided, landing 
platforms shall be provided for each 20 feet of height or fraction 
thereof. Each ladder section shall be offset from adjacent sections. 
Where installation conditions (even for a short, unbroken length) 
require that adjacent sections be offset, landing platforms shall be 
provided at each offset.
    (i) Where a man has to step a distance greater than 12 inches from 
the centerline of the rung of a ladder to the nearest edge of structure 
or equipment, a landing platform shall be provided. The minimum step-
across distance shall be 2\1/2\ inches.
    (ii) All landing platforms shall be equipped with standard railings 
and toeboards, so arranged as to give safe access to the ladder. 
Platforms shall be not less than 24 inches in width and 30 inches in 
length.
    (iii) One rung of any section of ladder shall be located at the 
level of the landing laterally served by the ladder. Where access to the 
landing is through the ladder, the same rung spacing as used on the 
ladder shall be used from the landing platform to the first rung below 
the landing.
    (3) Ladder extensions. The side rails of through or side-step ladder 
extensions shall extend 3\1/2\ feet above parapets and landings. For 
through ladder extensions, the rungs shall be omitted from the extension 
and shall have not less than 18 nor more than 24 inches clearance 
between rails. For side-step or offset fixed ladder sections, at 
landings, the side rails and rungs shall be carried to the next regular 
rung beyond or above the 3\1/2\ feet minimum (fig. D-10).
[GRAPHIC] [TIFF OMITTED] TC27OC91.010

                Figure D-10--Offset Fixed Ladder Sections
    (4) Grab bars. Grab bars shall be spaced by a continuation of the 
rung spacing when they are located in the horizontal position. Vertical 
grab bars shall have the same spacing as the ladder side rails. Grab-bar 
diameters shall be the equivalent of the round-rung diameters.
    (5) Ladder safety devices. Ladder safety devices may be used on 
tower, water tank, and chimney ladders over 20 feet in unbroken length 
in lieu of cage protection. No landing platform is required in these 
cases. All ladder safety devices such as those that incorporate

[[Page 130]]

lifebelts, friction brakes, and sliding attachments shall meet the 
design requirements of the ladders which they serve.
    (e) Pitch--(1) Preferred pitch. The preferred pitch of fixed ladders 
shall be considered to come in the range of 75 degrees and 90 degrees 
with the horizontal (fig. D-11).
[GRAPHIC] [TIFF OMITTED] TC27OC91.011

                   Figure D-11--Pitch of Fixed Ladders
    (2) Substandard pitch. Fixed ladders shall be considered as 
substandard if they are installed within the substandard pitch range of 
60 and 75 degrees with the horizontal. Substandard fixed ladders are 
permitted only where it is found necessary to meet conditions of 
installation. This substandard pitch range shall be considered as a 
critical range to be avoided, if possible.
    (3) Scope of coverage in this section. This section covers only 
fixed ladders within the pitch range of 60 degrees and 90 degrees with 
the horizontal.
    (4) Pitch greater than 90 degrees. Ladders having a pitch in excess 
of 90 degrees with the horizontal are prohibited.
    (f) Maintenance. All ladders shall be maintained in a safe 
condition. All ladders shall be inspected regularly, with the intervals 
between inspections being determined by use and exposure.