Add to MyChemicals Print Friendly Page
Chemical Datasheet

ACRYLIC ACID, INHIBITED

2
3 2
 
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.

CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.

CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.

DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.

NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and reactivity hazards, along with special hazards such as water- and air-reactivity. (The NFPA 704 diamond is also shown at the top of the datasheet.) See a guide to the NFPA diamond.

General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.

List of data sources.
UN/NA Number CAS Number CHRIS Code DOT Hazard Label
  • 79-10-7
  • CORROSIVE
  • FLAMMABLE LIQUID
NFPA 704:
  • Red 2 -- Flammability: Ignites when moderately heated
  • Blue 3 -- Health Hazard: Extremely hazardous - use full protection
  • Yellow 2 -- Reactivity: Violent chemical change possible
General Description
Acrylic acid is a colorless liquid with a distinctive acrid odor. Flash point 130°F. Boiling point 286°F. Freezing point 53°F. Corrosive to metals and tissue. Prolonged exposure to fire or heat can cause polymerization. If polymerization takes place in a closed container, violent rupture may occur. The inhibitor (usually hydroquinone) greatly reduces the tendency to polymerize.

Hazards

Reactivity Alerts - Special alerts if the chemical is especially reactive (see list of reactivity alerts).

Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.

Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).

Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).

Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).

Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.

List of data sources.
Reactivity Alerts
Air & Water Reactions
Flammable. Soluble in water. The presence of water, due to different solubilities of the acid and inhibitor (partitioning one from the other), may initiate polymerization.
Fire Hazard
Special Hazards of Combustion Products: Toxic vapors are generated when heated

Behavior in Fire: May polymerize and explode (USCG, 1999)
Health Hazard
May burn skin or eyes upon short contact. INHALATION: eye and nasal irritation and lacrimation. INGESTION: may cause severe damage to the gastrointestinal tract. (USCG, 1999)
Reactivity Profile
ACRYLIC ACID may polymerize violently especially when the frozen acid is partially thawed (freezing point 12°C or 53°F). Frozen acid should be melted at room temperature and the process should be well stirred. Do not use heat during the melting process [Kirk-Othmer, 3rd ed., Vol. 1, 1978, p. 330]. Corrodes iron and steel and polymerization may occur on contact with iron salts. The uninhibited acid polymerizes exothermically at ambient temperature and explodes if confined. The inhibitor (usually hydroquinone) greatly reduces the tendency to polymerize. Explosive polymerization can also occur with strong bases, amines, ammonia, oleum, chlorosulfonic acid, and peroxides. Mixing with 2-aminoethanol, 28% ammonium hydroxide, ethylenediamine or ethyleneimine in a closed container causes an increase in temperature and pressure. Can react violently with oxidizing reagents and strong bases [Bretherick, 5th ed., 1995, p. 419].
Belongs to the Following Reactive Group(s)

Response Recommendations

Firefighting - Response recommendations if the chemical is on fire (or near a fire).

Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).

Protective Clothing - Recommendations for protective gear and, in some cases, a table of breakthrough times for protective materials.

First Aid - Recommended first aid treatment for people exposed to the chemical.

List of data sources.
Firefighting
Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. Solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Use "alcohol" foam, dry chemical or carbon dioxide. Use water spray to knock-down vapors. (AAR, 2003)
Non-Fire Response
Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Use water spray to knock-down vapors. Neutralize spilled material with crushed limestone, soda ash, or lime. (AAR, 2003)
Protective Clothing
Skin: Wear appropriate personal protective clothing to prevent skin contact.

Eyes: Wear appropriate eye protection to prevent eye contact.

Wash skin: The worker should immediately wash the skin when it becomes contaminated.

Remove: Work clothing that becomes wet or significantly contaminated should be removed and replaced.

Change: No recommendation is made specifying the need for the worker to change clothing after the work shift.

Provide: Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substance; this is irrespective of the recommendation involving the wearing of eye protection. Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2003)
_____Dupont Average Standardized Breakthrough Times_____
(for ACRYLIC ACID)

Tychem® BR
     270 min.  (concentration:  95+%)
Tychem® CPF2
     greater than 480 min.  (concentration:  95+%)
Tychem® CPF4
     greater than 480 min.  (concentration:  95+%)
Tychem® F
     greater than 480 min.  (concentration:  99%)
Tychem® LV
     270 min.  (concentration:  95+%)
Tychem® QC
     immediate (less than 10 min.)  (concentration:  95+%)
Tychem® QC for Corrections
     immediate (less than 10 min.)  (concentration:  95+%)
Tychem® Reflector®
     270 min.  (concentration:  95+%)
Tychem® Responder®
     greater than 480 min.  (concentration:  99%)
Tychem® Responder® CSM
     greater than 480 min.  (concentration:  99%)
Tychem® SL
     greater than 480 min.  (concentration:  95+%)
Tychem® ThermoPro
     greater than 480 min.  (concentration:  100%)
Tychem® TK
     greater than 480 min.  (concentration:  95+%)  (DuPont, 2008)
Copyrighted information of E.I. du Pont de Nemours and Company. Tychem® is a registered trademark of E.I. du Pont de Nemours and Company.
First Aid
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.

SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas.

INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. IMMEDIATELY call a physician and be prepared to transport the victim to a hospital even if no symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing.

INGESTION: DO NOT INDUCE VOMITING. Corrosive chemicals will destroy the membranes of the mouth, throat, and esophagus and, in addition, have a high risk of being aspirated into the victim's lungs during vomiting which increases the medical problems. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. Transport the victim IMMEDIATELY to a hospital. (NTP, 1992)

Physical Properties

This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see definitions of each property). More property data is available for common chemicals.

Guide to toxic levels of concern (AEGLs, ERPGs, TEELs, and IDLH).

List of data sources.
Molecular Formula:
  • CH2CHCOOH
Flash Point: 130.0 ° F (NTP, 1992)
Lower Explosive Limit: 2.4 % (NTP, 1992)
Upper Explosive Limit: 8.0 % (NTP, 1992)
Autoignition Temperature: 820.0 ° F (USCG, 1999)
Melting Point: 55.0 ° F (NTP, 1992)
Vapor Pressure: 3.2 mm Hg at 68.0 ° F ; 5 mm Hg at 81.1° F (NTP, 1992)
Vapor Density: 2.5 (NTP, 1992)
Specific Gravity: 1.0497 at 68.0 ° F (USCG, 1999)
Boiling Point: 286.0 ° F at 760 mm Hg (NTP, 1992)
Molecular Weight: 72.06 (NTP, 1992)
Water Solubility: greater than or equal to 100 mg/mL at 63° F (NTP, 1992)
AEGL: data unavailable
ERPG-1 ERPG-2 ERPG-3
2.0 ppm 50.0 ppm 750.0 ppm
(AIHA, 2008)
TEEL: data unavailable
IDLH: data unavailable

Regulatory Information

Regulatory Names - Names under which this chemical is regulated under several U.S. federal laws: CAA (Clean Air Act of 1990), CERCLA (Comprehensive Environmental Response, Compensation, and Liability Act of 1980, also known as Superfund), EPCRA (Emergency Planning and Community Right-to-Know Act, also known as SARA Title III), and RCRA (Resource Conservation and Recovery Act of 1976).

CAA RMP - Indicates whether this chemical is regulated under Section 112(r) of the Clean Air Act, which lists about 100 toxic, flammable, or explosive hazardous substances. (Section 112(r) mandates the Risk Management Plan regulations.) For listed chemicals, the Threshold Quantity (from 40 CFR 68) is also shown. Facilities that use more than the threshold quantity of a listed chemical in a process are subject to the CAA accidental release prevention provisions.

CERCLA - Indicates whether this chemical is listed as a hazardous substance under CERCLA. For listed chemicals, the Reportable Quantity (from 40 CFR 302) is also shown. Facilities that spill more than the reportable quantity of a listed chemical must report it to federal, state, and local governments.

EHS (EPCRA 302) - Indicates whether this chemical is listed as an Extremely Hazardous Substance under Section 302 of EPCRA. For listed chemicals, the Threshold Planning Quantity (from 40 CFR 355) is also shown. Facilities that store more than the threshold quantity of an EHS chemical must meet the reporting, community right-to-know, and emergency planning requirements of EPCRA.

TRI (EPCRA 313) - Indicates whether this chemical is listed as a toxic chemical under Section 313 (Toxics Release Inventory) of EPCRA. Facilities that manufacture, store, or use significant amounts of Section 313 chemicals may be required to submit annual reports about any releases into the environment (see 40 CFR 372).

RCRA Chemical Code - 4-character identification code assigned to this substance under RCRA.
Regulatory Names:
  • ACRYLIC ACID
CAA RMP: Not a regulated chemical.
CERCLA: Regulated chemical with a Reportable Quantity of 5000 pounds.
EHS (EPCRA 302): Not a regulated chemical.
TRI (EPCRA 313): Regulated chemical.
RCRA Chemical Code: U008

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names, synonyms, and foreign names.