Table 5.2 Boating Facilities Alternatives Item: Gangways - Maximum Slope Proposed Guidelines: Exception permits gangways to exceed 1:12 maximum slope based on distance between design high point and level of water, and square footage of fixed and floating piers. Final Guidelines: Exception permits gangways to exceed 1:12 maximum slope where total length of gangways serving as part of accessible route is at least 80 feet. Small facilities with fewer than 25 boat slips are permitted to exceed 1:12 maximum slope where total length of gangways serving as part of accessible route is at least 30 feet. Item: Gangways - Alterations Proposed Guidelines: No exception. Final Guidelines: Where existing gangways are replaced or altered, gangways are not required to be lengthened unless triggered by alterations to primary function areas. Item: LULAs and Platform Lifts Proposed Guidelines: No exception. Final Guidelines: Limited use/limited application elevators (LULAs) and platform lifts permitted in lieu of gangways. Item: Boat Slips - Scoping Proposed Guidelines: At least 3% of boat slips required to be accessible. Final Guidelines: Number of boat slips required to be accessible ranges from at least 1 for facilities with 25 or fewer boat slips to 12 for facilities with 901 to 1000 boat slips (plus 1 additional accessible boat slip for each 100 boat slips over 1000). Item: Accessible Boat Slips - Location Proposed Guidelines: Accessible boat slips must be located nearest to amenities. Final Guidelines: No requirement. Item: Accessible Boat Slips - Clearances Proposed Guidelines: No exceptions. Final Guidelines: Exception permits clear pier space to be reduced to 36 inches wide minimum for length of 24 inches maximum, provided that multiple 36 inch wide segments are separated by segments that are 60 inches minimum clear in width and length. Exception also permits edge protection 4 inches high maximum and 2 inches deep maximum at continuous pier openings. Item: Accessible Boat Slips - Alterations Proposed Guidelines: No exception. Final Guidelines: Exception permits clear pier space to be located perpendicular to boat slip and extend width of boat slip in alterations to existing facilities, where facility has at least one boat slip with required clear pier space parallel to the boat slip and providing additional boat slips with required clear pier space parallel to the boat slip would result in reducing number of boat slips available or reducing widths of existing boat slips. Accessible Boat Slips - Cleats Proposed Guidelines: No provision. Final Guidelines: Cleats and other boat securement devices are not required to comply with height provisions for controls and operating mechanisms. Item: Boat Launch Ramps Proposed Guidelines: Where boarding piers are provided at boat launch ramps, at least one accessible boat slip required adjacent to a boat launch ramp. Final Guidelines: Where boarding piers are provided at boat launch ramps, at least 5% of boarding piers must be 60 inches wide minimum for entire length of boarding pier and be served by accessible route. Where accessible route serving floating boarding pier or skid pier is located within boat launch ramp, portion of accessible route within boat launch ramp not required to comply with ramp provisions. Accessible routes serving floating boarding piers permitted to use gangways exceptions for alterations, maximum rise, landings, handrail extensions, cross slope, LULAs and platform lifts. Maximum 1:12 slope does not apply where total length of gangways serving as part of accessible route is at least 30 feet.