The following table displays the analysis to be used, based on primary and secondary material data for the ply. (Skip table)
Applicability | Document(s) | ||||||
---|---|---|---|---|---|---|---|
Fiber or Particle | Matrix or Binder | Interphase | Metal or Ceramic | Substructure slicing | Subslicing | Analysis used | |
1 |
either | either | Error: no matrix, no fiber/particle, no interphase | ||||
2 |
either | either | Interphase | metal (reaction) | either | either | Error: both types of Interphase |
3 |
either | either | either | Yes | Yes | TP-3602, need at least one of matrix, fiber/particle, interphase | |
4 |
Interphase | either | Error: no matrix, also Interphase without fiber/particle | ||||
5 |
either | either | Error: no matrix | ||||
6 |
either | Interphase | either | Error: no matrix | |||
7 |
either | Interphase | either | Error: Interphase without fiber/particle | |||
8 |
either | either | TP-2515/ TP-3290 | ||||
9 |
fiber | matrix | metal (reaction) | TM-87154 | |||
10 |
fiber | matrix | non-metal | TP-2515/ TP-3290 | |||
11 |
fiber | matrix | Interphase | non-metal | Error: no analysis, but recommend slicing (see 14) or subslicing (see 3) | ||
12 |
fiber | matrix | metal (reaction) | sliced | Error: no analysis, but recommend NO slicing (see 9) | ||
13 |
fiber | matrix | non-metal | sliced | TP-3602 | ||
14 |
fiber | matrix | Interphase | non-metal | sliced | TP-3602 | |
15 |
particle | binder | metal (reaction) | Error: no analysis for particles | |||
16 |
particle | binder | non-metal | Particle in Equivalent Cube | |||
17 |
particle | binder | Interphase | non-metal | Particle in Equivalent Cube | ||
18 |
particle | binder | metal (reaction) | sliced | Error: no analysis for particles | ||
19 |
particle | binder | non-metal | sliced | Error: no analysis for particles, but recommend subslicing (see 3) | ||
20 |
particle | binder | Interphase | non-metal | sliced | Error: no analysis for particles, but recommend subslicing (see 3) |
"Error: no analysis for particles" indicates that although there is currently no such analysis, some could be generated or the reaction data ignored. If some analysis were generated, the substructured case would still not have any analysis as described below:
"Error: no analysis YET"
for substructured particles implies that the analysis for a
"Particle in Equivalent Cube" could be modified to
produce such analysis.
The current analysis uses the following diagram:
D
which could apply to either sliced or non-sliced data.
There are supplementary documents to TP-2515/ TP-3290: TM-83696/ TM-87295/ TM-83320