Skip to content.Skip to side navigation. Quick Navigation: Skip to content.Skip to side navigation.
GPO Access Home Page.
Jump to selected topic.
Navigation Bar
About.Help. A-Z Resource List. Locate a Federal Depository Library. Buy Publications. Legislative. Executive. Judicial.
National Archives and Records Administration logo.
Database Features.
Browse
Simple Search
Advanced Search
* Boolean
  * Proximity
Search History
Search Tips
Corrections

Latest Updates

User Info
FAQs
Agency List
e-CFR Main Page
Related Resources
Code of Federal Regulations
Federal Register
List of CFR
Sections Affected
Regulations.gov
Unified Agenda
All NARA Publications
About Government.
Ben's Guide Logo.
Get Adobe Reader

blue pill
e-CFR Data is current as of February 12, 2009


Title 40: Protection of Environment
PART 432—MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY

Browse Previous | Browse Next

Subpart F—Meat Cutters

§ 432.60   Applicability.

This part applies to discharges of process wastewater resulting from the production of fresh meat cuts, such as steaks, roasts, chops, etc. by a meat cutter.

§ 432.61   Special definitions.

For the purpose of this subpart:

(a) Finished product means the final product, such as fresh meat cuts including, but not limited to, steaks, roasts, chops, or boneless meats.

(b) Meat cutter means an operation which cuts or otherwise produces fresh meat cuts and related finished products from larger pieces of meat (carcasses or not carcasses), at rates greater than 6000 lbs (2730 kg) per day.

§ 432.62   Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:

(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:

Effluent Limitations

[BPT]

Regulated
parameter
Maximum daily1Maximum monthly avg.1
BOD50.0360.018
Fecal Coliform(2)(3)
O&G40.0120.006
TSS0.0440.022

1Pounds per 1000 lbs (or g/kg) of finished product.

2Maximum of 400 MPN or CFU per 100 mL at any time.

3No maximum monthly average limitation.

4May be measured as hexane extractable material (HEM).

(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS specified in paragraph (a) of this section.

§ 432.63   Effluent limitations attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BAT:

(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:

Effluent Limitations

[BAT]

Regulated
parameter
Maximum daily1Maximum monthly avg.1
Ammonia (as N)8.04.0

1mg/L (ppm).

(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the following effluent limitations:

Effluent Limitations

[BAT]

Regulated
parameter
Maximum daily1Maximum monthly avg.1
Ammonia (as N)8.04.0
Total Nitrogen194134

1mg/L (ppm).

§ 432.64   Pretreatment standards for existing sources (PSES). [Reserved]

§ 432.65   New source performance standards (NSPS).

Except as provided in paragraph (c) of this section, any source that is a new source subject to this subpart must achieve the following performance standards:

(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS specified in §432.62(a).

(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS specified in §432.62(b) and the limitations for ammonia (as N) and total nitrogen specified in §432.63(b).

(c) Any source that was a new source subject to the standards specified in §432.65 of title 40 of the Code of Federal Regulations, revised as of July 1, 2003, must continue to achieve the standards specified in this section until the expiration of the applicable time period specified in 40 CFR 122.29(d)(1) after which it must achieve the effluent limitations specified in §§432.62 and 432.63.

§ 432.66   Pretreatment standards for new sources (PSNS). [Reserved]

§ 432.67   Effluent limitations attainable by the application of the best control technology for conventional pollutants (BCT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BCT: Limitations for BOD5, fecal coliform, O&G, and TSS are the same as the corresponding limitation specified in §432.62.