* Area category and sic file: applicable only to cat. descriptions which are words (not codes) * modified by Strum to correct assigned SICs (4 total) which don't match given SICs (Linderman email of 5/21/01) * Category description c(90), sic c(4), 1x, SIC description c(50) MAKE A BEA POPN GROWTH FACTOR Animal Cremation POPNPopulation judgement call - not in EGAS4.0 EGAS SCC for population is 2460100000 MAKE AUTR IN BEA BY SETTING IT TO SIC=75 Autobody Refinishing Paint Application AUTRAuto repair shops EGAS4.0 SCC=2401005170, uses 752-754 MAKE COMM IN BEA BY SETTING IT TO 998 (MANUFACTURING) Cold Cleaning (Miscellaneous) DMANdurables manufacturing SIC 24, 25, 32-39 USE EGAS4.0 SCC=40100311 "cold cleaning entire unit" Consumer Products Usage POPNPopulation also in EGAS4.0 as population Drum and Barrel Reclamation COMMcommercial (FIRE, Retail and Wholesale trade, Services= SIC 50-67, 70-89)EGAS4.0 SCC=2461160000 based on AMS match of NTI with EGAS Extraction Solvent COMMcommercial (FIRE, Retail and Wholesale trade, Services= SIC 50-67, 70-89)EGAS4.0 SCC=2461160000 based on AMS match of NTI with EGAS WE wont have this category in AK/HI inventory, so don't do anything. Fuel Use FUELthis category is specific to Davidson Cty, Tenn and represents local data for all industiral, commercia/instituional and resid. fuels. can avge all IB, CH, RH GF's or use population MAKE AK/HI GOEX in BEA BY SETTING IT TO BEA POPN Gas Dispensing GOEXgas and oil expenditures Use SCC=2501060000 I think NTI has bad AMS. documentation says this category is for Davidson Cty Tenn and covers stage1&2&tank truck losses which matches to g&oil expend. Population MAKE AK/HI GOEX in BEA BY SETTING IT TO BEA POPN Gasoline Distribution Stage I GOEXgas and oil expenditures Use SCC=2501060000. stage 1, stage 2, all gasoline/all processes in this matches to EGAS4.0 gas&oil expend. MAKE AK/HI GOEX in BEA BY SETTING IT TO BEA POPN MAJOR BIN Gasoline Distribution Stage I GOEXgas and oil expenditures Use SCC=2501060000. stage 1, stage 2, all gasoline/all processes in this matches to EGAS4.0 gas&oil expend. MAKE AK/HI GOEX in BEA BY SETTING IT TO BEA POPN Gasoline Distribution Stage II GOEXgas and oil expenditures Use SCC=2501060000 MAKE AK/HI GEOP in BEA BY SETTING IT TO BEA POPN Geothermal Power GEOPelectricity, geothermal, national USE SIC=10101501 from EGAS4.0 electic.scc file MAKE AK/HI DMAN in BEA BY SETTING IT TO BEA 998 (MANUFACTURING) Halogenated Solvent Cleaners DMANDurables manufacturing: SIC 24, 25 32-39 based on match with EGAS4.0 SCC=2415000000 degreasing for all processes/industries and all solvents MAKE AK/HI DMAN in BEA BY SETTING IT TO BEA 998 Non-Halogenated Solvent Cleaning DMANDurables manufacturing: SIC 24, 25 32-39 based on match with EGAS4.0 SCC=2415000000 degreasing for all processes/industries and all solvents MAKE AK/HI MANT in BEA BY SETTING IT TO BEA 998 Hazardous Waste Incineration MANTtotal (durable/nondurable manufacturing SIC 20-39). use EGAS4.0 SCC=50300501. First I tried to match NTI AMS=260100000 which matches with EGAS4.0 on-site incineration all categories. doesn't seem like a good AMS. Next look at NTI SCC=503005, which is close to EGAS 50300501 which is haz waste incin. use this ma MAKE AK/HI IBCA in BEA BY SETTING IT TO BEA 998 Industrial Boilers: Coal, all types IBCAuse SCC=2102000000** there is none so use either 2102001000 and 2102002000 from ind_fuel.scc EGAS4.0 file (these appear to have same GF which is based on steam coal and doesnt distinguish betwen anthracite or bituminous) MAKE AK/HI IBDO in BEA BY SETTING IT TO BEA 998 Industrial Boilers: Distillate Oil IBDOuse SCC= 2102004000 from ind_fuel.scc EGAS4.0 file MAKE AK/HI IBNG in BEA BY SETTING IT TO BEA 998 Industrial Boilers: Natural Gas IBNGuse SCC = 2102006000 from ind_fuel.scc EGAS4.0 file MAKE AK/HI IBRO in BEA BY SETTING IT TO BEA 998 Industrial Boilers: Residual Oil IBROuse SCC = 2102005000 from ind_fuel.scc EGAS4.0 file MAKE AK/HI IBWO in BEA BY SETTING IT TO BEA 998 Industrial Boilers: Waste Oil IBWOuse SCC=2102012000 from ind_fuel.scc EGAS4.0 file MAKE AK/HI IBWW in BEA BY SETTING IT TO BEA 998 Industrial Boilers: Wood/Wood Residue IBWWuse SCC=2102008000 from ind_fuel.scc EGAS4.0 file MAKE AK/HI CHAC in BEA BY SETTING IT TO BEA 995 (Services and government enterprises) Institutional/Commercial Heating: Anthracite Coal CHACuse SCC= 2103001000 from com_fuel.scc file *check to make sure 2103001000 and 2103002000 have different GF's MAKE AK/HI CHBL in BEA BY SETTING IT TO BEA 995 (Services and government enterprises) Institutional/Commercial Heating: Bituminous and Lignite CHBLuse SCC=2103002000 from com_fuel.scc file MAKE AK/HI CHDO in BEA BY SETTING IT TO BEA 995 (Services and government enterprises) Institutional/Commercial Heating: Distillate Oil CHDOuse SCC=2103004000 from com_fuel.scc file MAKE AK/HI CHNG in BEA BY SETTING IT TO BEA 995 (Services and government enterprises) Institutional/Commercial Heating: Natural Gas CHNGuse SCC=2103006000 from com_fuel.scc file MAKE AK/HI CHRO in BEA BY SETTING IT TO BEA 995 (Services and government enterprises) Institutional/Commercial Heating: Residual Oil CHROuse SCC=2103005000 Services and government enterprises MAKE AK/HI CHWW in BEA BY SETTING IT TO BEA 995 (Services and government enterprises) Institutional/Commercial Heating: Wood/Wood Residue CHWWuse SCC=2103008000995 Services and government enterprises Lamp Breakage POPNnot a big category, not in EGAS4.0 population is a judgement call Motor Vehicle Fires POPNEGAS4.0 uses population for this category (see AMS 281005000) MAKE AK/HI CPET in BEA BY SETTING IT TO BEA SIC=13 Natural Gas Transmissions and Storage CPETCrude Petroleum, Natl gas&gas liquids, SIC 131 and 132. USE EGAS4.0SCC=40400301 match based on category name. looked up AMS=25000000 but not in EGAS4.0. matched by name to EGAS4.0 category called "Oil and gas field storage and working tanks" On-Site Waste Incineration POPNNTI AMS=26010000 which represents all categories (res. commer. industrial) of incineration EGAS4.0 uses population for this AMS Open Burning: Forest and Wildfires ZEROEGAS 4.0 recommends Zero growth (gf=1 all States) Open Burning: Prescribed Burnings ZEROEGAS 4.0 recommends Zero growth (gf=1 all States) MAKE AK/HI MANT by setting it to BEA 998 Paint Stripping Operations MANTtotal (durable/nondurable manufacturing SIC 20-39). match with AMS=2440000000 in EGAS4.0 Reupholstery and furniture repair MAKE AK/HI RDUS in BEA BY SETTING IT TO BEA POPN Paved Road Dust RDUSRoad Dust: same for Unpaved or Paved. From Vmt_out.scc files SCC=2296000000 and SCC=2294000000 MAKE AK/HI RHAC in BEA BY SETTING IT TO BEA POPN Residential Heating: Anthracite Coal RHACuse SCC=2104001000 which is in the res_fuel_scc file MAKE AK/HI RHBC in BEA BY SETTING IT TO BEA POPNResidential Heating: Bituminous and Lignite Coal RHBCuse SCC= 2104002000 which is in the res_fuel_scc file MAKE AK/HI RHDO in BEA BY SETTING IT TO BEA POPNResidential Heating: Distillate Oil RHDOuse SCC = 2104004000 which is in the res_fuel_scc file MAKE AK/HI RHNG in BEA BY SETTING IT TO BEA POPN Residential Heating: Natural Gas RHNGuse SCC = 2104006000 which is in the res_fuel_scc file MAKE AK/HI RHWW in BEA BY SETTING IT TO BEA POPN Residential Heating: Wood/Wood Residue RHWWuse SCC = 2104008000 which is in the res_fuel_scc file Residential Open Burning POPNPopulation matches with EGAS based on AMS code Soil Dust ZEROZero growth (recommended by Greg Stella, 5/15/2001) MAKE AK/HI ICDO in BEA BY SETTING IT TO BEA SIC=49 Stationary Internal Combustion Engines - Diesel ICDOuse SCC=2199004002 from EGAS4.0 area_fuel.SCC MAKE AK/HI ICNG in BEA BY SETTING IT TO BEA SIC=49 Stationary Internal Combustion Engines - Natural Gas ICNGuse SCC= 2199006002 from EGAS4.0 area_fuel.SCC MAKE AK/HI STUR in BEA BY SETTING IT TO BEA SIC=49 Stationary Turbines STURtalked to Simms Roy on 5/17 and he said % natl gas is 95% and % of dist. oil is 5%. Had no info on split between utlility, industrial and commercial so add them equally and explore ranges... do the following: 0.95*[avge of (SCC=20100201 from electric.scc + SCC=20200201 from ind_fuel.scc + SCC=20300203 from comm_fuel) + 0.05*[avge(SCC=20100101 from electric.scc, SCC=20200101 from ind_fuel.scc, 20300102 from comm_fuel.scc) Structure Fires POPNmatches EGAS MAKE AK/HI SARC in BEA BY SETTING IT TO BEA POPN Surface Coatings: Architectural SARCpaints and allied products-SIC 285. use EGAS4.0 SCC=2401001000 This matches with NTI AMS exactly Surface Coatings: Industrial Maintenance MANTtotal (durable/nondurable manufacturing SIC 20-39). use EGAS4.0 SCC=2401100000 which matches with NTI AMS. make sure matches with other MANT growth based on other SCCs MAKE AK/HI TRCT in BEA BY SETTING IT TO BEA SIC=16 (Highway and streetconstruction) Surface Coatings: Traffic Markings TRCTNTI AMS=2401008000 matches with EGAS4.0, so use EGAS4.0SCC=24010080000ighway and street construction Swimming Pools POPNPopulation Unpaved Road Dust RDUSRoad Dust: same for Unpaved or Paved. From Vmt_out.scc files SCC=2296000000 and SCC=2294000000