skip navigation
National Criminal Justice Reference Service
Login | Subscribe/Register | Manage Account | Shopping Cartshopping cart icon | Help | Contact Us | Home     
National Criminal Justice Reference Service
  Advanced Search
Search Help
     
| | | | |
place holder
Administered by the Office of Justice Programs U.S. Department of Justice Office of Justice Programs Seal National Criminal Justice Reference Service National Criminal Justice Reference Service Office of Justice Programs Seal National Criminal Justice Reference Service
Topics
A-Z Topics
Corrections
Courts
Crime
Crime Prevention
Drugs
Justice System
Juvenile Justice
Law Enforcement
Victims
Left Nav Bottom Line
Home / NCJRS Abstract

Publications
 

NCJRS Abstract


The document referenced below is part of the NCJRS Library collection.
To conduct further searches of the collection, visit the NCJRS Abstracts Database.

How to Obtain Documents
 
NCJ Number: NCJ 223115  
Title: Y-STR Analysis on DNA Mixture Samples--Results of a Collaborative Project of the ENFSI DNA Working Group
Journal: Forensic Science International: Genetics  Volume:2  Issue:3  Dated:June 2008  Pages:238 to 242
Author(s): Walther Parson ; Harald Niederstatter ; Alexandra Lindinger ; Peter Gill
Publisher Url*: http://www.elsevier.com 
Publication Date: 06/2008
Pages: 5
Type: Studies/research reports
Origin: Ireland
Language: English
Annotation: This article describes the material, methods, and results of the European Network of Forensic Science Institutes (ENFSI) DNA Working Group's collaborative project, which evaluated the performance of commercial Y-STR typing kits on mixture samples that contained minute amounts of male DNA.
Abstract: Although the kits apparently performed similarly with respect to specificity for male DNA when they were used in the 16 laboratories participating in the project, evaluators observed a significant variation in peak heights among the laboratories. This was observed for kits distributed by companies whose products are widely used (AB, Promega), as well as for products of companies that serve only the Middle-European market (Biotype, SERAC). The evaluators also observed that the overall peak heights were low. This means that if a minimal threshold value were to be applied to allele calling, as is the case for autosomal short tandem repeat (STR) typing, a large number of alleles would have been excluded from the report. Variation in the quantity and quality of the DNA shipped to the laboratories can be excluded as the reason for the observed difference, because samples and shipping conditions were determined to be reproducible in an earlier study. The DNA mixture samples were prepared by the organizing laboratory and thoroughly tested prior to shipping for the experiments. These findings show the need for an individual adaptation/optimization process in order to achieve comparable and optimal kit performance across laboratories. The following Y-STR typing kits were used in the main study: Y-filer (Applied Biosystems, AB, Foster City, CA); Argus Y Nonaplex (Biotype, Dresden, Germany); Powerplex Y (Promega, Madison, WI); and DYSplex-3 (without Amelogenin, SERAC Bad Homburg, Germany). 2 tables, 1 figures, 5 references, and appended list of participating laboratories and collaborating persons
Main Term(s): Criminology
Index Term(s): Crime laboratories ; Testing and measurement ; Interagency cooperation ; DNA fingerprinting ; Foreign criminal justice research ; Performance Measures ; Europe
 
To cite this abstract, use the following link:
http://www.ncjrs.gov/App/Publications/abstract.aspx?ID=245030