U.S. Department of Energy - Energy Efficiency and Renewable Energy

A Consumer's Guide to Energy Efficiency and Renewable Energy

Slab-on-Grade Foundation Moisture and Air Leakage Control

To maximize your home's energy efficiency and to protect the foundation, you should use the following moisture and air leakage control techniques when installing slab-on-grade floors:

  1. Keep all untreated wood materials away from the earth.

  2. Install well-designed guttering and downspouts that are connected to a drainage system, which diverts rainwater completely away from the house.

  3. Add a sill gasket membrane between the slab and bottom plate to provide air sealing.

  4. Install a protective membrane (such as rubberized roofing material or ice-dam protection membranes) to serve as a capillary break that reduces wicking of water up from the foundation. This membrane can also serve as a termite shield.

  5. Install a foundation drain directly beside the bottom of the footing. The foundation drain assembly includes a filter fabric, gravel, and a perforated plastic drain pipe typically 4 inches in diameter. Locate the drain beside the footing, not on top, to avoid water flowing against the seam between the footing and the foundation wall, and to prevent wicking from a web footing through the stem wall.

  6. Install a capillary break and moisture barrier under the slab floor, consisting of a layer of 10-mil polyethylene vapor diffusion retarder placed over at least 4 inches of gravel.

Diagram of floating slab-on-grade construction. A corner of a foundation is shown, with cutouts to show the various levels of materials used. Between the wood wall and the foundation lies a flat sill gasket, and below that is metal termite flashing. Rigid insulation lines the exterior of the foundation wall, and the insulation is covered with a 10-mil poly vapor diffusion retarder. A gravel base surrounds the exterior of the foundation. A drainage pipe lies along the side of the exterior of the foundation, and a label reads: Perforated drainage pipe is embedded in gravel, covered with filter fabric, and located at lower perimeter of foundation footing to provide drainage.

Learn More

Financing & Incentives

Reading List

  • Weather-Resistive Barriers (PDF 223 KB). (October 2000). DOE/GO-102000-0769. U.S. Department of Energy.
  • Jackson, D. (August 2000). "Practical Foundation Waterproofing," Journal of Light Construction. (18:11) pp. 65-69.