**************************** Run Number: 3779 End of Run Comment: Run_type=Production,target_type=Carbon 50 degs Left,beam_e0=0.739,beam_raster=on,leftarm_p=0.216492,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.267104,rightarm_theta=120,rightarm_colli=out,comment_text=production PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=1 ps4=2 ps5=65535 ps6=65535 ps7=9999 ps8=65535 EVENTS : 687638 TIME : 41.461 mins DEAD TIME: 4.53% TRIGGER RATES: PRES/REAL T3:273.4/273.4 Hz T4:16.2/32.3 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz TRIGGER TOTALS: PRES/REAL T3: 680049/680049 T4: 40222/80444 T5: 0/0 T8: 38/2547355 AVERAGE CURRENT BCM x1 : 39.6647uA BCM x3 : 39.9457uA BCM x10: 35.1616uA APPROXIMATE BCM CHARGES (C) BCM u1 : 0.09888 BCM u3 : 0.09888 BCM u10: 0.08705 BCM d1 : 0.09846 BCM d3 : 0.09986 BCM d10: 0.08789 **************************** End-of-run EPICS data for Run Number 3779 at Wed Dec 12 06:55:31 EST 2007 Wien angle : 86.0395 Half-wave plate (off=out) : IN Left Arm D1 momentum : 0.216463 Left Arm arm angle : 120 Right Arm D1 momentum : 0.24874 Right Arm arm angle : 119.998 HALLA:p : 739.524 HALLA:dpp : -9.70129e-05 Tiefenbach Hall A energy : 739.528 Left Arm Top VDC Current : 3.02734 Left Arm Bottom VDC Current : 4.3457 Left Arm Q1 momentum : 0.216544 Left Arm Q1 power supply : 159.846 Left Arm Q1 gauss meter : -0.013526 Left Arm Q2 gauss meter : 0.04932 Left Arm Q2 power supply current : 91.9424 Left Arm Q2 momentum : 0.216398 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 70.1268 Left Arm D1 momentum : 0.216463 Left Arm D1 NMR : 0.404146 Left Arm Q3 gauss meter : -0.04248 Left Arm Q3 power supply current : 83.4567 Left Arm Q3 momentum : 0.216376 Left Arm Q3 power supply polarity : disabled Right Arm Q1 momentum : 0.249523 Right Arm Q1 power supply : 184.36 Right Arm Q1 gauss meter : -0.004726 Right Arm Q2 power supply current : 106.373 Right Arm Q2 momentum : 0.248829 Right Arm Q2 gauss meter : 0.05628 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 80.3365 Right Arm D1 momentum : 0.248712 Right Arm D1 NMR : 0.246863 Right Arm Q3 power supply current : 98.1824 Right Arm Q3 momentum : 0.248909 Right Arm Q3 gauss meter : 0.04417 Right Arm Q3 power supply polarity : disabled Average current of the two cavities : 47.5738 Current on Unser monitor : 59.0527 Current on Upstream bcm : 47.6234 Current on Downstream bcm : 47.5241 Upstream Cavity Coefficient : 43.377 Downstream Cavity Coefficient : 42.913 Current on IBC0L02 (source) : 114.287 Hall C Current : 67.5 MBSY1c magnet current (amp) : 30.4 MBSY1c Bdl : 184479 Hall A momentum (Tiefenbach) (HALLA:p) : 739.528 Hall A momentum orbit correction (dpp) : -9.26441e-05 Hall A setup momentum (MMSHLAE) : 739.375 Hall A energy (halla_MeV) : 739.528 Hall C energy (hallc_MeV) : 2847.99 Delta(E)/E width (MV_AI_DXWID) : 1.41963 IPM1C12.XPOS : -0.0671089 IPM1H04A.XPOS : -1.22874 IPM1H04A.YPOS : -0.277013 IPM1H04B.XPOS : -1.99731 IPM1H04B.YPOS : 0.016091 Left Arm Collimator : 0.871289 HacL_HPE1313A:0_Ch58 : -0.319336 HacL_HPE1313A:0_Ch55 : 22.5586 HacL_HPE1313A:0_Ch54 : -0.288086 SLI data valid? : No SLI horiz size mm : 0 SLI Energy spread *10^5 : 0 SLI x position : 1.84845 SLI vert. size mm : 0 SLI y position : 1.41221 ----- Target : Beam Left C fan frequency loop 1 : 59.5 fan frequency loop 3 : 59.5 Encoder position : 693532 Target type : 693532 temperature loop 1(1) : 7.01 temperature loop 1(3) : 7.05 Heat exchange He : 7.4 temperature loop 3(1) : 18.83 temperature loop 3(3) : 19.01 Heat exchange H2 : 18.5 HPH He loop 1 : 202.507 HPH He loop 2 : 0.00147881 HPH H2 loop 3 : 368.848 -----