Image Description - 0814-2 A table is captioned "Table 2. Failure Mechanisms/Screening Methods". It specifies the distribution of failures and screening tests for several failure mechanisms. The metallization failure mechanism indicates that it accounts for 11 percent of failures and that burn-in, internal visual, temperature cycling, scanning electron microscope for metallization are the applicable screen tests. The diffusion failure mechanism accounts for 1 percent of failures and burn-in is the applicable screen test. The oxide faults failure mechanism accounts for 14 percent of failures and burn-in is the applicable screen test. The bulk failure mechanism accounts for 3 percent of failures and stabilization bake, burn-in, and temperature cycling are the applicable screen tests. The surface failure mechanism accounts for 21 percent of failures and internal visual, radiography, PIND, constant acceleration, stabilization bake and burn-in are the applicable screen tests. The interconnect failure mechanism accounts for 9 percent of failures and temperature cycling, burn-in, and constant acceleration are the applicable screen tests. The wire bound failure mechanism accounts for 1 percent of failures and nondestructive bond pull, stabilization bake, temperature cycling, constant acceleration, internal visual, burn-in, radiography, and PIND are the applicable screen tests. The package failure mechanism accounts for 40 percent of failures and PIND, radiography, seal, external visual, temperature cycling, and constant acceleration are the applicable screen tests.