Image Description - 0802-3 A table is captioned "Table 3. Typical Precautions/Safeguards for Ni-H2 battery Testing". The table includes a list of nine preventative measures to be used during battery testing. These are: 1. Prepare a comprehensive test plan before starting a long-life test, 2. A Safety Review Panel should review test plans and monitor the test program, 3. Batteries should be insulated to prevent convective heat transfer, 4. Tests should be conducted with the cells located in a thermally-controlled chamber with an inert gas environment, 5. All cells in a battery arrangement should be instrumented, 6. At least one engineer should be available to monitor every three tests in progress, 7. Backup uninterruptible power supplies or generators should be provided for the test facility, 8. Automatic load removal should be activated if the power goes off, 9. Periodic test reports should be prepared with distribution to all concerned parties.