Electrical Metrology Low Frequency AC/DC
Station Status Parameter Range
MRDL-001 Class-1

DC ohms

0.1 to 0.95 ohm
1 ohm
1 to 100 ohm
100 to 109 ohm
109 to 1012 ohm
DC Volts 0.002 to 1000 V
10 V
1 to 30 Kv
DC Current 10-12 to 10-7 amp
10-7 to 1 amp
1 to 15 amp
15 to 100 amp
AC Volts (RMS) 10 mv to 1000V
AC Amps (RMS) 0.001 to 1 A
1 A to 11 A
MRDL-007 Class-3 AC Impedance
(0 to 30 Mhz)
Capacitance
Inductance


10-15 to .01 F
10-7 to 1000 H
MRDL-004 Class-1 AC / DC Elec Power
(Low freq Sinusoid) watts
(Low freq Sinusoid) vars

50 Kw
50 Kva
Station Status Designations:
Class-1 An active metrology station for which continuous traceability is maintained by internal redundancy, cross checks, and periodic recalibration of primary standards by external agency. Uncertainties established by accepted statistical treatment of historical data. Customers are charged the established hourly rate for direct calibration time for their instrument.
Class-2 A metrology station for which we have sufficient equipment to perform a traceable calibration but the equipment is not maintained under current statistical control. A setup and precalibration may be required before performing calibrations. Uncertainties are established by statistical analysis of pre-cal and cal data from the current calibration. No historical tracking is done. Customers are charged the established hourly rate for direct calibration time for their instrument, but not for set-up and pre-cal time unless negotiated in advance.
Class-3 A special calibration or test for which we have the necessary equipment and experience, but may require setup and pre-cal before performing the test. These tests are negotiated individually with the customer on a full cost recovery basis. 

 
Services Request Contacts:
 
   
Robert P. Effler
(Group Leader)
William E. Wright
(Technical Manager)
Harry E. Smith
(Standards Manager and Operations Coordinator)

                                Back

 

 

 

 

 

 

 

Electrical Metrology Time / Freq / RF / mwave
Station Status Parameter Range
MRDL-008 Class-1

Time & Frequency
(WWV + Crystal Oscillator)
long term stability
loc osc. stability

(Loran-C)
long term stability
loc osc. stability






1 Ghz
MRDL-009 Class-2

RF
Power

 
Station Status Designations:
Class-1 An active metrology station for which continuous traceability is maintained by internal redundancy, cross checks, and periodic recalibration of primary standards by external agency. Uncertainties established by accepted statistical treatment of historical data. Customers are charged the established hourly rate for direct calibration time for their instrument.
Class-2 A metrology station for which we have sufficient equipment to perform a traceable calibration but the equipment is not maintained under current statistical control. A setup and precalibration may be required before performing calibrations. Uncertainties are established by statistical analysis of pre-cal and cal data from the current calibration. No historical tracking is done. Customers are charged the established hourly rate for direct calibration time for their instrument, but not for set-up and pre-cal time unless negotiated in advance.

 
Services Request Contact:

Robert P. Effler
(Group Leader)

 

William E. Wright
(Technical Manager)

 

Harry E. Smith
(Standards Manager and Operations Coordinator)

                                Back

 

 

 

 

 

 

 

 

 

 

 

Physical Metrology Pressure & Vacuum

Station Status Parameter  Range
MRDL-016 Class-1

Vacuum
low vacuum
high vacuum

10-3 torr to 1 torr
10-8 to 10-3 torr
MRDL-030 Class-2

Sound & Acoustics
10 to 15000 hz (audio)

0 to 200 dB
 
Station Status Designations:
Class-1 An active metrology station for which continuous traceability is maintained by internal redundancy, cross checks, and periodic recalibration of primary standards by external agency. Uncertainties established by accepted statistical treatment of historical data. Customers are charged the established hourly rate for direct calibration time for their instrument.
Class-2 A metrology station for which we have sufficient equipment to perform a traceable calibration but the equipment is not maintained under current statistical control. A setup and precalibration may be required before performing calibrations. Uncertainties are established by statistical analysis of pre-cal and cal data from the current calibration. No historical tracking is done. Customers are charged the established hourly rate for direct calibration time for their instrument, but not for set-up and pre-cal time unless negotiated in advance.
 
Services Request Contact:

Robert P. Effler
(Group Leader)

 

William E. Wright
(Technical Manager)

 

Harry E. Smith
(Standards Manager and Operations Coordinator)

                                Back

 

 

 

 

 

 

 

 

Physical Metrology Flow
Station Status Parameter Range
MRDL-024 Class-1 Liquid Flow
low range . hi accuracy
hi range water
0 to 10 lpm
0.1 to 95 GPM
MRDL-025 Class-1 Gas Flow .. Low Range
< 10 sccm .. (Air / N2 / He / Ar)
< 20 slm .. (Air / N2 / He / Ar)
< 10 sccm .. (other gases)
< 20 slm .. (other gases)
0.1 to 10 sccm
0.1 to 20 slm
0.1 to 10 sccm
0.1 to 20 slm
MRDL-026 Class-1 Gas Flow .. Med Range
(air / n2 / he / ar)
0.2 to 100 scfm
MRDL-027 Class-1 Gas flow & velocity
air flow
air velocity - low
air velocity - hi
100 to 4000 scfm
0 to 2000 fpm
0 to 9000 fpm
Station Status Designations:
Class-1 An active metrology station for which continuous traceability is maintained by internal redundancy, cross checks, and periodic recalibration of primary standards by external agency. Uncertainties established by accepted statistical treatment of historical data. Customers are charged the established hourly rate for direct calibration time for their instrument.
Class-2 A metrology station for which we have sufficient equipment to perform a traceable calibration but the equipment is not maintained under current statistical control. A setup and precalibration may be required before performing calibrations. Uncertainties are established by statistical analysis of pre-cal and cal data from the current calibration. No historical tracking is done. Customers are charged the established hourly rate for direct calibration time for their instrument, but not for set-up and pre-cal time unless negotiated in advance.
Class-3 A special calibration or test for which we have the necessary equipment and experience, but may require setup and pre-cal before performing the test. These tests are negotiated individually with the customer on a full cost recovery basis.

 
Services Request Contact:

Robert P. Effler
(Group Leader)

 

William E. Wright
(Technical Manager)

 

Harry E. Smith
(Standards Manager and Operations Coordinator)

                                Back

 

 

 

 

Physical Metrology Temperature
Station Status Parameter Capabilities Range
MRDL-014 Class-1 Temperature
cryogenics
low temp
near-ambient
medium temp ranges
0 to 200 C
200 to 1100 C
MRDL-015 Class-1 Optical Pyrometry 800 to 3000 C
Station Status Designations:
Class-1 An active metrology station for which continuous traceability is maintained by internal redundancy, cross checks, and periodic recalibration of primary standards by external agency. Uncertainties established by accepted statistical treatment of historical data. Customers are charged the established hourly rate for direct calibration time for their instrument.
Services Request Contact:

Robert P. Effler
(Group Leader)

 

William E. Wright
(Technical Manager)

 

Harry E. Smith
(Standards Manager and Operations Coordinator)

                                Back

 

 

 

 

 

 

 

 

 

Physical Metrology Physical Chemistry & Thermodynamics
Station Status Parameter Range
MRDL-019 Class-1 Humidity 5 to 100% RH
-80 to 0 C dewpoint
MRDL-023 Class-1 Density & Specific Grav
gases
liquids
solids
Volume

0.08 to 300 sg
0.08 to 300 sg
0.08 to 300 sg
0.001 to 10 L
Station Status Designations:
Class-1 An active metrology station for which continuous traceability is maintained by internal redundancy, cross checks, and periodic recalibration of primary standards by external agency. Uncertainties established by accepted statistical treatment of historical data. Customers are charged the established hourly rate for direct calibration time for their instrument.