Table 2. Analytical methods used to measure the carbon system parameters

No.

Cruise name

Period

Dissolved inorganic carbon

Total alkalinitya

CO2 fugacity

pH

1

A21/A12

1/23/90-3/8/90

Coulometer

-

Gas chromatographyb

-

2

A09

2/10/91-3/23/91

SOMMAc

Fulld

-

-

3

A16S

7/11/91-9/2/91

SOMMA

Full

Infrared analysise

-

4

A01E

9/2/91-9/26/91

SOMMA

Full

-

-

5

A12B

5/21/92-8/5/92

Coulometer

-

-

-

6

A05

7/15/92-7/23/92

Calculated

1-point

-

Electrode

7

A10

12/27/92-1/31/93

SOMMA

Full

-

-

8

A11

12/22/92-2/1/93

-

-

-

-

9

A07

1/2/93-1/10/93

Gas chromatography

-

Gas chromatography

Electrode

10

A06

1/2/93-3/19/93

Gas chromatography

-

Gas chromatography

Electrode

11

A16N

7/4/93-8/30/93

SOMMA

Full

Infrared analysise

Spectrophotometric

12

A17

1/4/94-3/22/94

SOMMA

1-point

-

Potentiometricf

13

A15

4/3/94-5/21/94

SOMMA

Full

-

-

14

A08

3/29/94-5/11/94

SOMMA

-

Gas chromatographyg

-

15

A13

2/20/95-3/2/95

SOMMA

1-point

-

-

16

A14

1/12/95-2/16/95

SOMMA

1-point

-

Potentiometric

17

A23

3/20/95-5/6/95

Coulometer

-

Gas chromatographyh

-

18

A01W

6/95-7/95

Coulometer

Full

-

-

19

A12BR

3/17/96-5/20/96

Coulometer

-

-

-

20

A02

6/11/97-7/3/97

SOMMA

Full

-

-

21

A20

7/17/97-8/10/97

SOMMA

Full

-

Electrode

22

A22

8/15/97-9/3/97

SOMMA

Full

-

Electrode

23

A24

8/15/97-9/3/97

SOMMA

Full

-

Electrode

24

A05R

1/24/98-2/23/98

SOMMA

Full

Gas chromatographyg

Spectrophotometric

25

A01WR

6/22/98-7/8/98

Coulometer

Full

-

Electrode

aDetermined by potentiometric titration, either a full curve ("Full") or a single-point ("1-point") titration.

b500-mL samples, analysis by gas chromatography. (Chipman, D. W., J. Marra, and T. Takahashi. Primary production at 47° N and 20° W in the North Atlantic Ocean: A comparison between the 14C incubation method and mixed layer carbon budget observations. Deep-Sea Research II 40, 151-69, 1993.)

cSingle-operator multiparameter metabolic analyzer.

dAnalyzed shoreside.

e500-mL samples, infrared analysis. [Wanninkhof, R., and K. Thoning. Measurement of fugacity of CO2 in surface water using continuous and discrete sampling methods. Mar. Chem. 44 (2-4), 189-205, 1993.]

fA17C only.

g60- or 120-mL samples, analysis by gas chromatography. (Neill, C., K. M. Johnson, E. Lewis, and D. W. R. Wallace. Small volume, batch equilibration measurement of fCO2 in discrete water samples. Limnol. Oceanogr. 42, 1774-83, 1997.)

hMeasured at 4°C.


tracz 6/4/2003