Title 7: Agriculture
PART 801—OFFICIAL PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT
Browse Previous | Browse Next
§ 801.8 Tolerances for sieves.
The maintenance tolerances for sieves used in performing official inspection services shall be:
(a) Thickness of metal: ±0.0015 inch.
(b) Accuracy of perforation: ±0.001 inch from design specification.
(c) Sieving accuracy:
Sieve description | Tolerance |
---|
Direct comparison | Sample exchange |
---|
.064×
3/8 inch oblong | ±0.2 percent, mean deviation from standard sieve using wheat | ±0.3 percent, mean deviation from standard sieve using wheat |
5/64×
3/4 inch slotted | ±0.3 percent, mean deviation from standard sieve using barley | ±0.5 percent, mean deviation from standard sieve using barley |
5
5/64×
3/4 inch slotted | ±0.5 percent, mean deviation from standard sieve using barley | ±0.7 percent, mean deviation from standard sieve using barley |
6/64×
3/4 inch slotted | ±0.7 percent, mean deviation from standard sieve using barley | ±1.0 percent, mean deviation from standard sieve using barley |