WHP Cruise Summary Information WOCE section designation A24 Expedition designation (EXPOCODE) 316N151_2 Chief Scientist(s) and their affiliation Lynne Talley, SIO Dates 1997.05.30 - 1997.07.05 Ship KNORR Ports of call Ponta Delgada, Azores to Halifax, Nova Scotia Number of stations 153 Geographic boundaries of the stations 97°64.8''N 98°42.9''W 49°9.3''W 01°38.8''N Floats and drifters deployed 12 PALACE floats and 17 RAFOS floats Moorings deployed or recovered 1 RAFOS source (also 2 RAFOS sources on initial transit) Contributing Authors (in order of appearance) F. Delahoyde K. Sanborn E. Firing M. Vollmer L. Arlen S. Khatiwala Cruise report for WOCE A24 Knorr 151, leg 2:Ponta Delgada, Azores to Halifax, NS, Canada A. Cruise Narrative Ship: R/V KNORR operated by Woods Hole Oceanographic Institution Ports: Ponta Delgada, Azores to Halifax, NS, Canada Dates: 30 May 1997 depart Ponta Delgada, 5 July 1997 arrive Halifax WOCE Designator: 316N151_2 Chief Scientist: Lynne D. Talley Scripps Institution of Oceanography University of California San Diego 9500 Gilman Dr. La Jolla, CA 92093-0230 e-mail: ltalley@ucsd.edu telephone: (619)534-6610 fax: (619)534-9820 A hydrographic survey consisting of CTD/rosette sections between the Azores and Greenland was carried out May to July, 1997. The R/V Knorr departed Ponta Delgada, Azores on 30 May 1997. 153 CTD/Rosette stations were occupied from 30 May through 28 June. Water samples (up to 31) and CTD data were collected in most cases to within 10 meters of the bottom, for a total of 3450 bottles. Salinity, dissolved oxygen and nutrient samples were analyzed from every level sampled by the rosette. The cruise ended in Halifax, Nova Scotia on 5 July 1997. 1 URI RAFOS Mooring, 12 ALACE floats, 17 Rafos floats, and 45 XBT's were deployed during the cruise. Two RAFOS moorings were also deployed on the transit from Woods Hole to Ponta Delgada. These sections are part of the WOCE Atlantic Climate Change Experiment, and their purpose is to assist in measuring the upper water transports in the eastern subpolar gyre, including those which feed the Norwegian Sea and the Labrador Sea, and to observe the overflows from the Greenland-Iceland-Norwegian Seas in the Denmark Strait, Iceland Basin and Rockall Trough. Primary measurement programs included hydrography (CTDO, salinity, oxygen, nutrients, CFC's, carbon dioxide, helium, tritium), and velocity (shipmounted ADCP, lowered ADCP, neutrally buoyant floats ALACE and RAFOS). A RAFOS sound source mooring was placed during the Greenland-Azores leg of the cruise. A transit leg to the Azores left from Woods Hole, MA on May 15, 1997, with chief scientist Tom Rossby. Underway to Ponta Delgada, two RAFOS sound source moorings were deployed, at 47°N, 39°W and 47°N, 31°W. Four sections were completed as part of the main cruise. After departing Ponta Delgada, we sailed to Terceira, Azores and began the first section there, proceeding northeastward towards the Goban Spur. Upon completion of the first section, we diverted into the harbor in Cork, Ireland, for an emergency exchange of crewmembers. The time associated with this was approximately 22 hours beyond that which was expected for a direct transit to the next section. The first section crossed the Mediterranean Water/Labrador Sea Water mixing zone obliquely, with large variations between groups of station dominated by Mediterranean Water and those dominated by Labrador Sea Water. The second (short) section crossed the southern Rockall Trough, from Porcupine Bank to the southern end of Rockall Bank. Due to time limitations imposed by the emergency trip to Cork, the full set of short sections occupied near Porcupine Bank in November 1996 were not repeated. The northernmost section was angled more northwest-southeast than in fall, 1996, in order to reach a portion of Rockall Bank which would still allow a boundary for the Wyville Thomson overflow, which was found below 1200 meters in the northern part of Rockall Trough. This strategy was successful, and overflow water was found on our short section, hugging Rockall Bank. The third section crossed the northern part of the subpolar gyre, from the Hebrides to Rockall Bank, to Hatton Bank, to the Reykjanes Ridge and to Greenland near Angmassalik. The eastern end of this section was moved north from that in November 1996 because the Meteor (chief scientist Walter Zenk) completed a section identical to the November section in May, 1997, just weeks before our arrival in the area. Therefore we chose to cross Rockall Trough farther north, just north of Anton Dohrn Seamount. The relocated section joined the original section in the middle of the Iceland Basin and then exactly duplicated the November, 1996 section to Greenland. Ice conditions at Greenland were favorable, and stations were completed well up onto the deep shelf (average depth 500 meters), although not as far west as in November, 1996. This section as a whole clearly delineated the overflow waters in each of the three troughs Irminger Basin, Iceland Basin and Rockally Trough. After a transit southward to Cape Farewell, Greenland, the fourth section was completed from Cape Farewell southeastward to the Charlie Gibbs Fracture Zone (CGFZ), and thence to Terceira. Time permitted an additional station in the CGFZ, allowing the cross-channel velocity (LADCP) and temperature/salinity structure to be delineated and a geostrophic velocity profile to be computed. Full water column bottle sampling was not included on the northern station. Time permitted additional stations on the southern end of the section. The last station was a double cast, with the first cast being a test of LADCP bottom tracking, and the second cast being the complete cast with bottle sampling. Measurement Programs The principal programs of A24 are shown in Table A.1. The SIO ODF hydrographic measurements program is described in section 1 following. Section 2 describes the ADCP/LADCP program, section 3 the CFC program, section 4 the alkalinity program, section 5 the CO2 program (no information included), and section 6 the helium/tritium/18O program. Analysis Institution Principal Investigator Basic Hydrography SIO Lynne Talley (Salinity, O2, Nutrients, CTD) CFC SIO Ray Weiss He/Tr/18O LDEO Peter Schlosser TCO2 BNL Doug Wallace TCO2 (reference samples)SIO Charles Keeling Alkalinity UH/RSMAS Frank Millero Transmissometer TAMU Wilf Gardner ADCP and LADCP UH Eric Firing, Peter Hacker PALACE/SOLO Floats SIO Russ Davis RAFOS Floats WHOI Amy Bower, Phil Richardson RAFOS Floats/Moorings URI Tom Rossby, Mary Elena Carr & Mike Prater pCO2 LDEO Taro Takahashi, Dave Chipman UW pH, TCO2 WHOI Catherine Goyet (Transit only) UW pH, TCO2 BNL Doug Wallace UW Meteorology/XBTs WHOI Barry Walden UW Thermosalinograph SIO Lynne Talley UW Sea surface/air gas SIO Ray Weiss analysis, pCO2, pN2O, pCH4, CH4, CO2, N2O Table A.1 Principal Programs of WOCE A24 Scientific Personnel Name Affiliation Duties Talley, Lynne SIO/PORD Chief Scientist Arlen, Linda LDEO TCO2 Becker, Susan SIO/STS/ODF Nutrients Boaz, John SIO/STS/ODF Watch Leader/O2/Rosette/Bottle data Chen, Shuiming UH ADCP/LADCP Costello, Lawrence WHOI Mooring, RAFOS Floats, Rosette Delahoyde, Frank SIO/STS/ODF CTD data Processing Firing, Eric UH ADCP/LADCP Galanter, Meredith UM/RSMAS Alkalinity Goen, Jamie UM/RSMAS Alkalinity Ha Min, Dong SIO/GRD CFC Johnson, Kenneth BNLT CO2 Khatiwala, Samar LDEO Helium, Tritium, O-18 Lavender, Kara SIO/PORD CTD Console/Sample Cop/Salinities/Rosette Mask, Andrea FSU CTD Console/Sample Cop/Salinities Masten, Douglas SIO/STS/ODF Nutrients Mattson, Carl SIO/STS/ODF TIC/Watch Leader/ET/Rosette Newton, David SIO/MLRG CTD Console/Rosette/Sample Cop Packard, Greg WHOI SSSG Technician Rusk, Steven SIO/STS/ODF O2/Rosette Sanborn, Kristin SIO/STS/ODF Bottle data/Salinities/Rosette/O2 Smith, Daniel LDEO Helium, Tritium, O-18 Van Woy, Frederick SIO/GRD CFC Vollmer, Martin SIO/GRD CFC Wilson, Angela LDEO pCO2 Table A.2 Scientific Personnel WOCE A24 1. Hydrographic Measurements Program The hydrographic measurements program consisted of salinity, dissolved oxygen and nutrient (nitrite, nitrate, phosphate and silicate) measurements made from bottles taken on CTD/rosette casts plus pressure temperature, salinity and dissolved oxygen from CTD profiles. Rosette casts were made to within 10 meters of the bottom. No major problems were encountered during the operation. The resulting data set met and in many cases exceeded WHP specifications. The distribution of samples is illustrated in figures 1.0-1.3. Figure 1.0 Sample distribution, stations 1-34. Figure 1.1 Sample distribution, stations 35-48. Figure 1.2 Sample distribution, stations 49-97. Figure 1.3 Sample distribution, stations 98-153. Description of Measurement Techniques 1.1. Water Sampling Package Hydrographic (rosette) casts were performed with a 36-place 10-liter rosette system consisting of a 36-bottle rosette frame (ODF), a 36-place pylon (General Oceanics 1016, SBE 32) and 31 10-liter PVC bottles (ODF). Underwater electronic components consisted of an ODF-modified NBIS Mark III CTD with dual conductivity and temperature sensors, SeaTech transmissometer, RDI LADCP, Simrad altimeter and Benthos pinger. The CTD was mounted horizontally along the bottom of the rosette frame, with the transmissometer, dissolved oxygen and SBE 35 PRT sensors deployed alongside. The LADCP was mounted vertically, inside the rosette frame bottle rings. The Simrad altimeter provided distance-above-bottom in the CTD data stream. The Benthos pinger was monitored during a cast with a precision depth recorder (PDR) in the ship's laboratory. The rosette system was suspended from a new three-conductor 0.322" electromechanical (EM) cable which was installed prior to the ship's departure from Woods Hole. Power to the CTD and pylon was provided through the cable from the ship. Separate conductors were used for the CTD and pylon signals with the General Oceanics 1016 pylon (casts 001/01-010/01). A single conductor was used with the SBE 32 pylon and SBE 33 deck unit (casts 011/01-153/02). The rosette system was deployed from the starboard side hangar, using an air- powered cart to move the rosette into the sampling area. The portside Markey CTD winch was used throughout the leg. The deck watch prepared the rosette 45 minutes prior to a cast. All valves, vents and lanyards were checked for proper orientation. The bottles were cocked and all hardware and connections rechecked. Upon arrival on station, time, position and bottom depth were logged and the deployment begun. The rosette was moved into position under a projecting boom from the rosette room using an air-powered cart on tracks. Two stabilizing tag lines were threaded through rings on the frame. CTD sensor covers were removed and the pinger turned on. Once the CTD acquisition and control system in the ship's laboratory had been initiated by the console operator and the CTD and pylon had passed their diagnostics, the watch leader would verify with the bridge that deployment could begin. The winch operator would raise the package and extend the boom over the side of the ship. The package was then quickly lowered into the water, the tag lines removed and the console and winch operators notified by radio of the target depth (wire-out). During each cast, the rosette was lowered to 5-10 meters above the bottom. Bottles on the rosette were identified with unique serial numbers. These numbers corresponded initially to the pylon tripping sequence 1-31, the first trip closing bottle #1. No bottles were changed during the leg. Averages of CTD data corresponding to the time of bottle closure were associated with the bottle data during a cast. Pressure, depth, temperature, salinity and density were immediately available to facilitate examination and quality control of the bottle data as the sampling and laboratory analyses progressed. At the end of the cast, two tugger lines terminating in large snap hooks were mounted on poles and used by the deck watch to snag recovery rings on the rosette frame. The package was then lifted out of the water, the boom retracted, and the rosette lowered onto the cart. Sensor covers were replaced, the pinger turned off and the cart and rosette moved into the rosette room for sampling. A detailed examination of the bottles and rosette would occur before samples were taken, and any extraordinary situations or circumstances noted on the sample log for the cast. Rosette maintenance was performed on a regular basis. O-rings were changed as necessary and bottle maintenance performed each day to insure proper closure and sealing. Valves were inspected for leaks and repaired or replaced. 1.2. Underwater Electronics Packages CTD data were collected with modified NBIS Mark III CTDs (ODF CTD #3, #5). CTD #3 was used on a single cast (001/01). An unstable PRT temperature channel was traced to a small leak in the PRT turret and was repaired. CTD #3 was subsequently maintained as the backup CTD. CTD #5 was deployed on all other casts (002/01- 153/02). This instrument provided pressure, temperature, conductivity and dissolved O2 channels, and additionally provided redundant PRT temperature and conductivity channels. Other data channels included elapsed-time, an altimeter, several power supply voltages, a second dissolved O2 channel and a transmissometer. The instrument supplied a standard 17-byte NBIS-format data stream at a data rate of 20 fps. Modifications to the instrument included revised pressure and dissolved O2 sensor mountings; ODF-designed sensor interfaces for O2 and the SeaTech transmissometer; implementation of 8-bit and 16-bit multi-plexer channels; an elapsed-time channel; instrument id in the polarity byte and power supply voltages channels. The instrument sensor configuration is provided in Table 1.2.0. Sensor Manufacturer Serial Notes Pressure Paine 211-35-440-05 77017 Primary Temperature Rosemount 171BJ 15407 Primary Conductivity GO 09035-00151 E197 Primary Temperature Rosemount 171BJ 15046 Secondary Conductivity GO 09035-00151 E184 Secondary Dissolved O2 SensorMedics 6-02-07 Primary Dissolved O2 Royce Secondary, experimental Table 1.2.0 CTD #5 sensor configuration data. The CTD pressure sensor mounting had been modified to reduce the dynamic thermal effects on pressure. The sensor was attached to a length of coiled, oil-filled stainless-steel tubing threaded into the end-cap pressure port. The transducer was also insulated. The NBIS temperature compensation circuit on the pressure interface was disabled; all thermal response characteristics were modeled and corrected in software. The SensorMedics O2 sensor was deployed in a pressure-compensated holder assembly mounted separately on the rosette frame and connected to the CTD by an underwater cable. The O2 sensor interface was designed and built by ODF. A second, experimental O2 sensor (Royce) was also deployed to collect some comparison data. A SBE 35 Laboratory-grade reference PRT was employed as an additional temperature calibration check. This device is internally-recording and triggered by the SBE 32 pylon confirmation signal, providing a calibration point for each bottle trip. Standard CTD maintenance procedures included soaking the conductivity and O2 sensors in distilled water between casts to maintain sensor stability, and protecting the CTD from exposure to direct sunlight or wind to maintain an equilibrated internal temperature. A General Oceanics 1016 36-place pylon was employed for the first 10 casts, then was replaced by a SBE 32 36-place pylon and SBE 33 deck unit for the rest of the cruise. The SBE 32 has the advantage of requiring a single sea cable conductor for power and signals, in contrast to the 2 required for the General Oceanics 1016. It also provides for the use of the SBE 35 reference PRT. Both pylons provided generally reliable operation and positive confirmation of all bottle trip attempts. A software configuration problem that caused some erroneously reported trip failures was corrected by station 27. 1.3. Navigation and Bathymetry Data Acquisition Navigation data were acquired from the ship's Trimbal Pcode GPS receiver via RS- 232. It was logged automatically at one minute intervals by one of the Sun Sparcstations. Underway bathymetry was acquired from the ship's SeaBeam system (center beam depth) at five-minute intervals, then merged with the navigation data to provide a time-series of underway position, course, speed and bathymetry data. These data were used for all station positions, PDR depths, and for bathymetry on vertical sections [Cart80]. 1.4. CTD Laboratory Calibration Procedures Laboratory calibrations of the CTD pressure and temperature sensors were used to generate tables of corrections applied by the CTD data acquisition and processing software at sea. Pressure and temperature calibrations were last performed on CTD #5 at the ODF Calibration Facility (La Jolla) in April, 1997, prior to WOCE A24. The CTD pressure transducer (Paine 211-35-440-05 8850 psi, Serial #77017) was calibrated in a temperature-controlled water bath to a Ruska Model 2400 Piston Gauge pressure reference. Calibration curves were measured at -0.39 and 11.57°C to two maximum loading pressures (1191 and 6081 db). Figure 1.4.0 summarizes the laboratory pressure calibration performed in April, 1997. Figure 1.4.0 Pressure calibration for ODF CTD #5, April 1997. CTD PRT temperatures were calibrated to a NBIS ATB-1250 resistance bridge and Rosemount standard PRT. The primary (Rosemount 171BJ, Serial #15407) and secondary (Rosemount 171BJ, Serial #15046) CTD temperatures were offset by 1.5C to avoid the 0-point discontinuity inherent in the internal digitizing circuitry. Figure 1.4.1 summarizes the laboratory temperature calibration performed on the primary PRT April, 1997. Figure 1.4.1 Temperature calibration for ODF CTD #5, April 1997. These calibration procedures will be repeated when the instrument is returned to ODF. 1.5. CTD Data Acquisition, Processing and Control System The CTD data acquisition, processing and control system consisted of a Sun SPARCstation 5 computer workstation, ODF built CTD deck unit, SBE 33 pylon deck unit and power supply and a VCR recorder for real-time analog backup recording of the sea cable signal. The Sun system consisted of a color display with trackball and keyboard (the CTD console), 18 RS-232 ports, 4.5 GB disk and 8-mm cartridge tape. Two other Sun systems (one Sparc 5, one Sparc LX) were networked to the data acquisition system, as well as to the rest of the networked computers aboard the Knorr. These systems were available for real-time CTD data display as well as providing hydrographic data management and backup. An HP 1200C color inkjet printer provided hardcopy from any of the workstations. The CTD FSK signal from the sea cable was demodulated and converted to a 9600 baud RS-232°C binary data stream by the CTD deck unit. This data stream was fed to the Sun SPARCstation. The pylon deck unit was also connected to the Sun through a bi- directional 300 baud serial line, allowing rosette trips to be initiated and confirmed through the data acquisition software. A bitmapped color display provided interactive graphical display and control of the CTD rosette sampling system, including real-time raw and processed data displays, navigation, winch and rosette trip displays. The CTD data acquisition, processing and control system was prepared by the console watch a few minutes before a deployment. A console operations log was maintained for each deployment, containing a record of every attempt to trip a bottle as well as any pertinent comments. Most CTD console control functions, including starting the data acquisition, were performed by pointing and clicking a trackball cursor on the display at pictures representing functions to perform. The system would then present the operator with a short dialog prompting with automatically-generated choices that could either be accepted as default or overridden. The operator was instructed to turn on the CTD and pylon power, then to examine a real-time CTD data display on the screen for stable voltages from the underwater unit. Once this was accomplished, the data acquisition and processing was begun and a time and position automatically associated with the beginning of the cast. The backup analog recording of the CTD signal on a VCR tape was started. A rosette trip display and pylon control window popped up, giving visual confirmation that the pylon was initializing properly. Various plots and displays were initiated. When all was ready, the console operator informed the deck watch by radio. Once the deck watch had deployed the rosette, the deck watch leader provided the winch operator with a target depth (wire-out) and lowering rate (normally 60 meters/minute or less for this package). The console operator would examine the processed CTD data during descent via interactive plot windows on the display, which could also be initiated from other workstations on the network. Additionally, the operator would decide where to trip bottles on the up cast, noting this on the console log. The PDR was monitored to insure the bottom depth was known at all times. The rosette distance above the bottom was monitored by the deck watch leader using the distance between the rosette pinger signal and its bottom reflection displayed on the PDR. The winch, altimeter and PDR displays allowed the watch leader to refine the target depth relayed to the winch operator and safely approach to within 10 meters of the bottom. Bottles would be closed on the up cast by pointing the console trackball cursor at a graphic firing control and clicking a button. The data acquisition system would respond with the CTD rosette trip data and a pylon confirmation message in a window. All tripping attempts were noted on the console log. The console operator would then direct the winch operator to the next bottle stop. The console operator was also responsible for generating the sample log for the cast. After the last bottle was tripped, the console operator would inform the deck watch and the rosette would be brought on deck. Once on deck, the console operator would terminate the data acquisition and turn-off the CTD, pylon and VCR recording. The VCR tape was filed. Frequently the console operator would also bring the sample log to the rosette room and serve as the sample cop. 1.6. CTD Data Processing ODF CTD processing software consists of some 35-odd programs running under the Unix operating system. The initial CTD processing program (ctdba) is used either in real-time or with existing raw data sets to: - Convert raw CTD scans into scaled engineering units, and assign the data to logical channels; - Filter data channels according to specified filtering criteria; - Apply sensor or instrument-specific response correction models; - Provide periodic averages of the channels corresponding to the output time- series interval; and - Store the output time-series in a CTD-independent format. Once the CTD data are reduced to a standard-format time series, they can be manipulated in a number of various ways. Channels can be additionally filtered. The time-series can be split up into shorter time-series or pasted together to form longer time-series. A time-series can be transformed into a pressure-series, or a different interval time-series. Calibration corrections to the series are maintained in separate files and are applied whenever the data are accessed. ODF data acquisition software acquired and processed the CTD data in real-time, providing calibrated, processed data for interactive plotting and reporting during a cast. The 20 fps data from the CTD were filtered, response-corrected and averaged to a 2 hz time-series. Sensor correction and calibration models were applied to pressure, temperature, conductivity and O2. Rosette trip data were extracted from this time-series in response to trip initiation and confirmation signals. The calibrated 2 hz time-series data were stored on disk (as were the 20 hz raw data) and were available in real-time for reporting and graphical display. At the end of the cast, various consistency and calibration checks were performed, and a 2.0 db pressure-series of the down-cast was generated and subsequently used for reports and plots. CTD plots generated automatically at the completion of deployment were checked daily for potential problems. The two PRT temperature sensors were inter-calibrated and checked for sensor drift. The CTD conductivity sensor was monitored by comparing CTD values to check-sample conductivities and by deep TS comparisons with adjacent stations. The CTD dissolved O2 sensor was calibrated to check-sample data. A few casts exhibited conductivity offsets due to biological or particulate artifacts. On some casts, noise in the O2 channel was evident. In these cases additional filtering was applied to the 2 hz time-series, using a spike-removal filter that replaced points exceeding (by a specified multiple of the standard deviation) the least-squares polynomial fit of specified order of segments of the data. The filtered points were replaced by the filtering polynomial value. Table 1.6.0 provides a list of all CTD casts requiring special attention. Cast Problems Solutions 001/01 CTD #3 temp offsets (water in turret). Switch to CTD #5. 001/01 Temperature drift on down cast. Use up cast. 004/01 Winch stopped for maintenance @ 2370M Filtered. d/c, o2 affected. 005/01 raw serial in crash on up cast, Time offset. restarted. 007/01 Surf cond spike. Filtered. 011/01 Cond drop-out@8.2deg theta d/c. Filtered. 011/01 Switched to SBE 32 pylon. 019/01 Deck unit blew fuse @1700M d/c, not Yo removed, filtered. noticed until 2100M. Power restored, returned to 1700M, then continued. 025/01 O2 sensor cover left on. No O2. 027/01 SBE pylon no-confirms-really time Software change for glitches in CTD#5. timing source. 028/01 O2 spike@3100db d/c. Filtered. 029/01 Bottom cond spike. Filtered. 032/01 Surf cond spike. Filtered. 037/01 Surf cond spike. Filtered. 038/01 Surf cond spike. Filtered. 039/01 Surf cond spike. Filtered. 040/01 Probably touched bottom. Filtered. 040/01 Cond spike@100M d/c. Filtered. 053/01 Surf cond spike (rain). No action. 055/01 Cond spike @ 5M d/c. Filtered. 058/01 Surf cond spike (rain). No action. 068/01 Surf O2 attenuated. Filtered. 069/01 Surf O2 exaggerated. Filtered. 070/01 Surf O2 exaggerated. Filtered. 071/01 Cond dropout @30M d/c. Filtered. 072/01 Surf O2 exaggerated. Filtered. 073/01 Surf O2 attenuated. Filtered. 074/01 Surf O2 attenuated. Filtered. 076/01 Surf O2 spike. Filtered. 082/01 Cond spike @1000M d/c. Filtered. 086/01 Surf O2 attenuated. Filtered. 089/01 Discovered W. Gardner's transmissometer Switched to instrument log. #266AD (from #265AD). 090/01 Salinity spiking on u/c @ rosette trips.Filtered. 113/01 Surf cond spike. Filtered. 132/01 Cond spike @ 6.8°C theta d/c. Filtered. 142/01- 146/01 Cond offsets on upcast. Calibration shift. 147/01 O2 drop-out on entry. Filtered. 147/01 Cond spike @ 9.7°C theta d/c. Filtered. 150/01 Cond spike @ 8.1°C theta u/c. No action. 151/01 Cond spikes @ 700-630M u/c. No action. Table 1.6.0 Tabulation of problem CTD casts. 1.7. CTD Shipboard Calibration Procedures ODF CTD #3 was used for a single cast (001/01) and developed a turret leak, which was repaired. ODF CTD #5 was used for all subsequent casts. A SBE 35 Laboratory-grade reference PRT was deployed on the rosette as a cross calibration for the primary and secondary PRT temperatures. CTD conductivity and dissolved O2 were calibrated to in-situ check samples collected during each rosette cast. CTD Pressure and Temperature The final pressure and temperature calibrations will be determined when CTD #5 is returned to ODF. Based on the secondary PRT comparisons and the conductivity calibration, there were no significant shifts in the CTD pressure or temperature. The primary PRT (serial #15407) appeared to hold its calibration relative to the SBE 35 to within 0.0005°C. The secondary PRT (serial #15046) appeared to drift by 0.003°C over the cruise and had drifted by 0.005°C since calibration in April. Figures 1.7.0 and 1.7.1 summarize the comparisons between the SBE 35 reference PRT and the primary and secondary PRT temperatures. Figure 1.7.0 Comparison between SBE 35 reference and primary PRT temperatures. Figure 1.7.1 Comparison between SBE 35 reference and secondary PRT temperatures. Conductivity The CTD rosette trip pressure and temperature and the bottle salinity were used to calculate a bottle conductivity. Differences between the bottle and CTD conductivities were then used to derive a conductivity correction. This correction is normally linear for the 3cm conductivity cell employed in the Mark III. Conductivity differences were fit to CTD conductivity for each cast, and the mean of the conductivity correction slopes examined: Figure 1.7.2 Conductivity correction slopes, per station. No significant change in the conductivity correction slope occurred over the cruise. Conductivity differences were then fit to CTD conductivity for all bottles to determine a mean conductivity correction slope: Figure 1.7.3 Mean conductivity correction slope, all stations. Since the mean correction slope did not significantly differ from the mean of individual slopes, the mean correction slope was applied and individual correction offsets fit for each cast. The resulting correction was adjusted for minor non- linearities in conductivity and pressure. Figure 1.7.4 illustrates the correction offsets by station after applying the correction slope: Figure 1.7.4 Conductivity correction offsets, all stations. The final form of the applied conductivity correction was: Gcorr=Graw-9.13543e-11P2+1.80848e-07P+0.0000147071G2raw 0.00176569Graw+coffset(1.7.0) where: Gcorr = Corrected conductivity (mmhos/cm); Graw = Raw sensor conductivity; P = Corrected CTD pressure (db); and Coffset = Coefficient derived from the fit to bottle conductivity. Deep potential temperature-salinity overlays of successive CTD casts were then examined for consistency and the corrections fine-tuned. Figures 1.7.5, 1.7.6 and 1.7.7 summarize the residual differences between bottle and CTD salinities after applying the conductivity correction. Figure 1.7.5 Salinity residual differences after correction, by pressure. Figure 1.7.6 Salinity residual differences after correction, by station. Figure 1.7.7 Deep salinity residual differences after correction, by station. Note that some pressure-related nonlinearity exists after correction. This could have been further reduced by increasing the complexity of the correction. 3 from the mean residual in Figures 1.7.6 and 1.7.7, or ±0.003 PSU for all salinities and ±0.0019 PSU for deep salinities represents the limit of repeatability of the bottle salinities with all sources of variation (e.g., Autosal, rosette, operators and samplers) included. This limit agrees with station overlays of deep TS. Within a cast (a single salinometer run), the precision of bottle salinities appears to exceed 0.001 PSU. The precision of the CTD salinities appears to exceed 0.0005 PSU. CTD Dissolved Oxygen The CTD dissolved O2 sensor (serial #6-02-07) worked without major problems the entire cruise. A series of consecutive casts (072/01-076/01, 086/01) exhibited some minor surface response problems. There are a number of problems with the response characteristics of the Sensormedics O2 sensor used in the NBIS Mark III CTD, the major ones being a secondary thermal response and a sensitivity to profiling velocity. Because of these problems, CTD rosette trip data cannot be directly calibrated to O2 check samples. Instead, down-cast CTD O2 data are derived by matching the up-cast rosette trips along isopycnal surfaces. The differences between CTD O2 modeled from these derived values and check samples are then minimized using a non-linear least- squares fitting procedure. Figures 1.7.8 and 1.7.9 show the residual differences between the corrected CTD O2 and the bottle O2 (ml/l) for each station. Figure 1.7.8 O2 residual differences after correction, by station. Figure 1.7.9 O2 residual differences (>2000db). Note that the mean of the differences is not zero, because the O2 values are weighted by pressure before fitting. The standard deviations of 0.071 ml/l for all oxygens and 0.037 ml/l for deep oxygens are only intended as metrics of the goodness of the fits. ODF makes no claims regarding the precision or accuracy of CTD dissolved O2 data. The general form of the ODF O2 conversion equation follows Brown and Morrison [Brow78] and Millard [Mill82], [Owen85]. ODF does not use a digitized O2 sensor temperature to model the secondary thermal response but instead models membrane and sensor temperatures by low-pass filtering the PRT temperature. In-situ pressure and temperature are filtered to match the sensor response. Time-constants for the pressure response tau-p, and two temperature responses tau-Ts and tau-Tf are fitting parameters. The sensor current, or Oc, gradient is approximated by low-pass filtering 1° Oc differences. This term attempts to correct for reduction of species other than O2 at the cathode. The time-constant for this filter, tau-og, is a fitting parameter. Oxygen partial-pressure is then calculated: Opp=[c1Oc+c2]fsat(S,T,P)e(c3Pl+c4Tf+c5Ts+c6(dOc/dt)) (1.7.1) where: Opp = Dissolved O2 partial-pressure in atmospheres (atm); Oc = Sensor current (amps); fsat(S,T,P)= O2 saturation partial-pressure at S,T,P (atm); S = Salinity at O2 response-time (PSUs); T = Temperature at O2 response-time (C); P = Pressure at O2 response-time (decibars); Pl = Low-pass filtered pressure (decibars); Tf = Fast low-pass filtered temperature (C); Ts = Slow low-pass filtered temperature (C); dOc/dt = Sensor current gradient (amps/secs). 1.8. Bottle Sampling At the end of each rosette deployment water samples were drawn from the bottles in the following order: - CFCs; - 3He; - O2; - pCO2; - Total CO2; - Alkalinity; - Tritium; - Nutrients; - Salinity; - 18O/16O. Note that some properties were sub-sampled by cast or by station, so the actual sequence of samples drawn was modified accordingly. The correspondence between individual sample containers and the rosette bottle from which the sample was drawn was recorded on the sample log for the cast. This log also included any comments or anomalous conditions noted about the rosette and bottles. One member of the sampling team was designated the sample cop, whose sole responsibility was to maintain this log and insure that sampling progressed in proper drawing order. Normal sampling practice included opening the drain valve before opening the air vent on the bottle, indicating an air leak if water escaped. This observation together with other diagnostic comments (e.g., "lanyard caught in lid", "valve left open") that might later prove useful in determining sample integrity were routinely noted on the sample log. Drawing oxygen samples also involved taking the sample draw temperature from the bottle. The temperature was noted on the sample log and was sometimes useful in determining leaking or mis-tripped bottles. Once individual samples had been drawn and properly prepared, they were distributed to their laboratory for analysis. Oxygen, nutrients and salinity analyses were performed on computer-assisted (PC) analytical equipment networked to Sun SPARC Stations for centralized data analysis. The analyst for a specific property was responsible for insuring that their results updated the cruise database. 1.9. Bottle Data Processing The first stage of bottle data processing consisted of verifying and validating individual samples, and checking the sample log (the sample inventory) for consistency. Oxygen flask numbers were verified, as each flask is individually calibrated and significantly affects the calculated O2 concentration. At this stage, bottle tripping problems were usually resolved, sometimes resulting in changes to the pressure, temperature and other CTD data associated with the bottle. The rosette bottle number was the primary identification for all samples taken from the bottle, as well as for the CTD data associated with the bottle. All CTD trips were retained whether confirmed or not so that they could be used to help resolve bottle tripping problems. Diagnostic comments from the sample log were then translated into preliminary WOCE quality codes, together with appropriate comments. Each code indicating a potential problem would be investigated. The next stage of processing would begin after all the samples for a cast had been accounted for. All samples for bottles suspected of leaking were checked to see if the properties were consistent with the profile for the cast, with adjacent stations and where applicable, with the CTD data. All comments from the analysts were examined and turned into appropriate water sample codes. The third stage of processing would continue throughout the cruise and until the data set is judged "final". Various property-property plots and vertical sections were examined for both consistency within a cast and consistency with adjacent stations. In conjunction with this process the analysts would review (and sometimes revise) their data as additional calibration or diagnostic results became available. Assignment of a WHP water sample quality code to an anomalous sample value was typically achieved through consensus. WHP water bottle quality flags were assigned with the following additional interpretations: 3 |An air leak large enough to produce an observable effect on a sample is |identified by a code of 3 on the bottle and a code of 4 on the oxygen. |(Small air leaks may have no observable effect, or may only affect gas |samples.) 4 |Bottles tripped at other than the intended depth were assigned a code of 4. |There may be no problems with the associated water sample data. 5 |No water sample data reported. This is a representative level derived from |the CTD data for reporting purposes. The sample number should be in the |range of 80-99. WHP water sample quality flags were assigned using the following criteria: 1 |The sample for this measurement was drawn from a bottle, but the results |of the analysis were not (yet) received. 2 |Acceptable measurement. 3 |Questionable measurement. The data did not fit the station profile or |adjacent station comparisons (or possibly CTD data comparisons). No notes |from the analyst indicated a problem. The data could be correct, but are |open to interpretation. 4 |Bad measurement. Does not fit the station profile, adjacent stations or |CTD data. There were analytical notes indicating a problem, but data values |were reported. Sampling and analytical errors were also coded as 4. 5 |Not reported. There should always be a reason associated with a code of 5, |usually that the sample was lost, contaminated or rendered unusable. 9 |The sample for this measurement was not drawn. WHP water sample quality flags were assigned to the CTDSAL (CTD salinity) parameter as follows: 2 |Acceptable measurement. 3 |Questionable measurement. The data did not fit the bottle data, or there |was a CTD conductivity calibration shift during the cast. 4 |Bad measurement. The CTD data were determined to be unusable for calculating |a salinity. 8 |The CTD salinity was derived from the CTD down cast, matched on an isopycnal |surface. WHP water sample quality flags were assigned to the CTDOXY (CTD oxygen) parameter as follows: 2 |Acceptable measurement. 4 |Bad measurement. The CTD data were determined to be unusable for calculating |a dissolved oxygen concentration. 5 |Not reported. The CTD data could not be reported. 9 |Not sampled. No operational dissolved oxygen sensor was present on this |cast. Note that all CTDOXY values were derived from the down cast data, matched to the upcast along isopycnal surfaces. Table 1.9.0 shows the number of samples drawn and the number of times each WHP sample quality flag was assigned for each basic hydrographic property: Rosette Samples Stations 1-153 Reported WHP Quality Codes Levels 1 2 3 4 5 8 9 Bottle 3451 0 3387 4 56 1 0 3 CTD Salt 3451 0 3441 10 0 0 0 0 CTD Oxy 3260 0 3260 0 0 157 0 34 Salinity 3438 0 3406 12 20 3 0 10 Oxygen 3434 0 3419 3 12 9 0 8 Silicate 3439 0 3431 5 3 3 0 9 Nitrate 3439 0 3436 0 3 3 0 9 Nitrite 3439 0 3436 0 3 3 0 9 Phosphate 3439 0 3435 0 4 3 0 9 Table 1.9.0 Frequency of WHP quality flag assignments. Additionally, all WHP quality code comments are presented in Appendix A. 1.10. Salinity Analysis Salinity samples were drawn into 200 ml Kimax high alumina borosilicate bottles after 3 rinses, and were sealed with custom-made plastic insert thimbles and Nalgene screw caps. This assembly provides very low container dissolution and sample evaporation. When loose inserts were found, they were replaced to ensure an airtight seal. Salinity was determined after a box of samples had equilibrated to laboratory temperature, usually within 8-12 hours of collection. The draw time and equilibration time, as well as per-sample analysis time and temperature were logged. Two Guildline Autosal Model 8400A salinometers (55-654 and 48-263) located in a temperature-controlled laboratory were used to measure salinities. The salinometers were modified by ODF and contained interfaces for computer-aided measurement. A computer (PC) prompted the analyst for control functions (changing sample, flushing) while it made continuous measurements and logged results. The salinometer cell was flushed until successive readings met software criteria for consistency, then two successive measurements were made and averaged for a final result. The salinometer was standardized for each cast with IAPSO Standard Seawater (SSW) Batch P-127, using at least one fresh vial per cast. The estimated accuracy of bottle salinities run at sea is usually better than 0.002 PSU relative to the particular Standard Seawater batch used. PSS-78 salinity [UNES81] was then calculated for each sample from the measured conductivity ratios, and the results merged with the cruise database. 3438 salinity measurements were made and 279 vials of standard water were used. Six of the vials were found to be bad. Salinometer 55-654 was used throughout this leg. Salinometer 48-263 was the backup salinometer and was not used. Various statistics pertaining to each run are summarized in Table 1.10.0. The temperature stability of the laboratory used to make the measurements was very good, ranging from 21.4 to 24.6°C. The salinometer bath temperature was maintained at 24°C. The salinities were used to calibrate the CTD conductivity sensor Autosal log starting 26/05/1997 Expedition: WOCE ACCE A24 Ship: R/V KNORR Salinometer serial number 55-654 St Cs Box Nbr Equ Date Start End Start End Bath Worm Start End Std Drift OPR Nbr Smp Hrs Time Time Air Air Temp Batch Sby Sby Dial 1 1 R 19 11.8 3105 1024 1147 23.2 23.3 24 P127 6494 6494 549 +0.00001 ACM 2 1 88 23 11.3 3105 1435 1643 23.2 23.4 24 P127 6494 6495 549 -0.00003 KLL 1 1 R 18 19.9 3105 1844 2024 22.9 23.0 24 P127 6516 6495 549 -0.00003 KLL Rerun of sta 3 1 5 23 15.1 3105 2342 0123 22.9 23.2 24 P127 6496 6494 549 +0.00000 KLL 7,12,14,15-loose thimble, 1st end SSW bad opened new vial 4 1 3 24 13.4 0106 0207 0332 23.2 22.7 24 P127 6495 6496 549 +0.00000 ACM 4 & 23-loose thimble, first end worm bad opened a new vial 5 1 J 24 10.4 0106 0447 0604 22.5 22.5 24 P127 6496 6496 550 -0.00001 ACM Bad 1st vial of SSW used 3 bottles initially 2 2 4 24 27.2 0106 0623 0748 22.3 22.4 24 P127 6496 6496 550 -0.00003 ACM 6 1 R 26 11.6 0106 1018 1202 22.8 23.1 24 P127 6496 6496 550 +0.00000 ACM 7 1 E 27 8.3 0106 1216 1453 23.1 22.9 24 P127 6496 6497 550 -0.00002 KLL 8 1 J 28 8.4 0106 1815 2025 22.5 22.6 24 P127 6496 6496 550 -0.00004 KLL 9 1 R 28 9.5 0206 0021 0207 22.3 22.6 24 P127 6496 6496 550 -0.00002 ACM 10 1 E 27 12.2 0206 0824 1007 22.4 22.6 24 P127 6496 6496 550 -0.00002 ACM 11 1 J 29 8.8 0206 1056 1300 22.6 22.9 24 P127 6498 6497 552 -0.00002 ACM 12 1 R 28 8.6 0206 1615 1857 22.9 22.9 24 P127 6498 6497 552 -0.00001 KLL 13 1 MT 20 11.3 0206 2236 0018 22.7 22.8 24 P127 6497 6497 552 -0.00002 KLL 14 1 4 24 8.4 0306 0037 0259 22.7 22.6 24 P127 6497 6497 552 -0.00001 ACM 15 1 J 30 11.9 0306 0813 1046 22.3 23.0 24 P127 6497 6497 552 -0.00002 ACM 16 1 E 31 11.5 0306 1544 1719 22.8 23.0 24 P127 6497 6497 552 -0.00001 KLL Maintenance done on the machine 17 1 R 30 11.7 0306 2156 2320 22.5 22.9 24 P127 6497 6497 552 -0.00002 KLL 18 1 J 31 12.6 0406 0331 0515 22.3 22.7 24 P127 6498 6497 552 -0.00002 ACM 19 1 E 32 11.3 0406 0832 1015 22.5 23.0 24 P127 6497 6497 552 -0.00001 ACM 20 1 R 31 10.5 0406 1409 1553 22.8 23.4 24 P127 6497 6497 552 +0.00000 KLL 21 1 J 31 10.9 0406 1923 2101 23.5 23.3 24 P127 6497 6497 552 -0.00001 KLL 22 1 E 31 11.5 0506 0145 0325 22.9 23.0 24 P127 6497 6498 551 +0.00001 ACM 23 1 R 31 11.2 0506 0557 0737 22.7 22.6 24 P127 6498 6497 551 -0.00002 ACM 24 1 J 31 10.9 0506 1118 1248 22.8 22.9 24 P127 6498 6497 551 -0.00000 ACM 25 1 E 31 8.8 0506 1429 1612 22.7 23.0 24 P127 6498 6498 551 -0.00001 KLL 26 1 R 31 8.8 0506 2030 2203 22.6 22.9 24 P127 6497 6497 551 -0.00002 KLL 27 1 J 31 11.0 0606 0354 0525 22.2 22.7 24 P127 6498 6498 551 -0.00002 ACM At start, SBY jumping by 3-5 units; stopped run started later 28 1 E 31 11.0 0606 0952 1125 22.6 22.9 24 P127 6499 6497 551 -0.00001 ACM 29 1 R 28 10.4 0606 1349 1506 22.5 22.7 24 P127 6498 6498 551 -0.00001 KLL 30 1 4 24 9.0 0606 1604 1711 22.7 22.8 24 P127 6498 6497 551 -0.00002 KLL 31 1 A 20 10.1 0606 1928 2028 22.6 22.9 24 P127 6498 6498 551 -0.00002 KLL 32 1 M 17 14.9 0706 0343 0437 22.5 22.7 24 P127 6498 6498 551 -0.00002 ACM 33 1 88 16 14.1 0706 0559 0653 22.5 22.7 24 P127 6497 6499 552 -0.00001 ACM 34 1 5 8 18.9 0706 1158 1222 22.4 22.7 24 P127 6499 6498 552 +0.00000 KLL 934 1 5 7 41.9 0806 1104 1149 22.3 22.4 24 P127 6499 6498 553 -0.00002 DN Test used 3 vials of worm at start 35 1 A 24 8.5 0906 0254 0415 21.9 21.8 24 P127 6501 6501 556 -0.00001 KMS Replaced btls 4,6,8 36 1 3 24 8.5 0906 0254 0415 21.9 21.8 24 P127 6501 6501 556 -0.00001 KMS Ran with Sta 35 37 1 83 24 11.0 0906 1009 1203 21.8 22.4 24 P127 6500 6501 557 -0.00000 ACM 38 1 4 24 11.7 0906 1340 1548 22.2 22.4 24 P127 6503 6501 557 +0.00001 KLL 39 1 A 24 12.4 0906 1817 2058 22.0 22.3 24 P127 6501 6500 557 -0.00004 KLL Replace pump washers, flushed cell tube; replace fill tube 40 1 3 24 12.9 0906 2223 2316 22.4 22.2 24 P127 6500 6499 552 -0.00001 KLL STD dial 557; mistyped as 552 41 1 88 23 13.3 1006 0249 0354 21.9 22.2 24 P127 6499 6499 557 +0.00006 ACM 42 1 4 24 15.5 1006 0910 1016 22.1 22.7 24 P127 6499 6500 557 +0.00002 ACM Used 2 vials of worm at start 43 1 R 24 17.7 1006 1405 1534 23.4 23.7 24 P127 6498 6498 556 +0.00003 SR more multiple attempts than noted 44 1 A 25 27.8 1006 1547 1648 23.7 23.4 24 P127 6498 6498 555 +0.00004 KLL 45 1 3 23 15.3 1006 1804 1936 23.1 23.4 24 P127 6499 6498 556 +0.00003 SR 46 1 88 19 15.1 1006 1952 2042 23.1 23.2 24 P127 6499 6499 556 +0.00002 KLL 47 1 B 15 19.4 1106 0201 0246 22.4 22.8 24 P127 6498 6499 556 +0.00001 DN 1st worm bad, used 2nd, total of 5 48 1 J 12 17.8 1106 0249 0320 22.8 22.7 24 P127 6498 6498 556 +0.00002 DN 49 1 A 7 8.9 1106 2107 2126 22.0 21.9 24 P127 6500 6499 556 +0.00000 KLL 50 1 3 10 8.1 1106 2126 2154 21.9 21.9 24 P127 6500 6499 556 +0.00000 KLL Ran with Sta 049 51 1 88 16 12.2 1206 0324 0403 21.9 22.0 24 P127 6498 6499 556 +0.00000 ACM 52 1 4 19 11.1 1206 0403 0449 22.0 21.9 24 P127 6498 6499 556 +0.00001 ACM Ran with Sta 051 53 1 B 24 10.6 1206 0700 0759 21.6 22.0 24 P127 6499 6509 556 -0.00001 ACM 54 1 A 24 8.6 1206 0829 0924 21.8 22.0 24 P127 6499 6499 556 +0.00004 ACM 55 1 3 21 9.9 1206 1310 1356 22.1 22.0 24 P127 6501 6490 556 +0.00000 KLL 56 1 88 21 8.1 1206 1356 1446 22.0 22.2 24 P127 6501 6499 556 +0.00000 KLL Ran with Sta 055 57 1 4 20 10.0 1206 1813 1856 21.6 21.7 24 P127 6489 6499 556 +0.00000 KLL 58 1 B 17 9.0 1206 1856 1936 21.7 21.9 24 P127 6489 6500 556 -0.00001 KLL Ran with Sta 057 59 1 A 15 10.4 1206 2203 2237 21.6 21.7 24 P127 6500 6501 557 +0.00000 KLL 60 1 J 8 10.0 1206 2237 2257 21.7 21.6 24 P127 6500 6500 557 -0.00000 KLL Ran with Sta 059 61 1 88 6 13.3 1306 0431 0445 21.7 21.7 24 P127 6500 6500 557 +0.00000 ACM 62 1 3 9 10.0 1306 0445 0512 21.7 21.8 24 P127 6500 6500 557 +0.00003 ACM Ran with Sta 061 63 1 R 10 11.9 1306 0905 0929 21.8 22.0 24 P127 6500 6499 557 +0.00000 ACM 64 1 A 14 8.3 1306 0930 1011 22.0 22.1 24 P127 6500 6500 557 +0.00000 ACM Ran with Sta 063 65 1 B 14 11.1 1306 1536 1607 22.2 22.5 24 P127 6500 6499 557 +0.00000 KLL 66 1 4 10 8.6 1306 1607 1636 22.5 22.5 24 P127 6500 6499 557 +0.00004 KLL Ran with Sta 065 67 1 A 17 12.3 1406 0030 0109 21.9 22.4 24 P127 6497 6498 555 +0.00000 ACM 68 1 3 24 10.2 1406 0110 0209 22.4 22.6 24 P127 6497 6498 555 +0.00000 ACM Ran with Sta 067 69 1 4 22 8.9 1406 0456 0548 22.2 22.5 24 P127 6498 6498 555 +0.00001 ACM 70 1 B 24 8.7 1406 0900 0955 22.4 22.7 24 P127 6497 6499 555 +0.00002 ACM 71 1 88 24 11.8 1406 1621 1711 22.7 23.1 24 P127 6499 6498 555 -0.00000 KLL 72 1 A 20 9.8 1406 1826 1908 22.9 22.9 24 P127 6498 6497 555 +0.00002 KLL 73 1 3 20 15.4 1506 0353 0439 22.1 22.6 24 P127 6498 6498 555 +0.00000 ACM 74 1 B 21 12.7 1506 0440 0528 22.6 22.6 24 P127 6498 6498 555 +0.00001 ACM Ran with Sta 073 75 1 88 21 12.8 1506 0941 1035 22.3 22.8 24 P127 6498 6497 555 +0.00000 KMS 76 1 A 18 10.8 1506 1036 1117 22.8 22.7 24 P127 6498 6498 555 +0.00000 KMS Ran with Sta 075 77 1 4 20 10.4 1506 1355 1435 22.2 22.6 24 P127 6498 6498 555 +0.00000 KLL 78 1 R 16 8.9 1506 1435 1510 22.6 22.7 24 P127 6498 6498 555 -0.00001 KLL Ran with Sta 077 79 1 B 14 10.5 1506 1841 1912 22.1 22.5 24 P127 6499 6499 555 +0.00000 KLL 80 1 3 20 9.1 1506 1912 1956 22.5 22.7 24 P127 6499 6498 555 +0.00001 KLL Ran with Sta 079 81 1 A 21 13.6 1606 0240 0327 22.0 22.3 24 P127 6499 6498 555 +0.00000 ACM 82 1 4 22 10.6 1606 0327 0420 22.3 22.2 24 P127 6499 6499 555 +0.00001 ACM Checked/changed Boxes A & B; Ran with Sta 081 83 1 R 28 10.5 1606 0757 0859 22.0 22.4 24 P127 6498 6498 555 +0.00002 ACM 84 1 J 25 13.9 1606 1601 1653 22.3 22.8 24 P127 6498 6499 555 +0.00000 KLL 85 1 E 25 10.9 1606 1754 1846 22.5 22.8 24 P127 6498 6499 555 +0.00001 KLL 86 1 R 27 9.9 1606 2056 2151 22.4 22.8 24 P127 6499 6499 555 -0.00001 KLL 87 1 A 29 9.9 1706 0148 0253 22.1 22.5 24 P127 6498 6498 555 +0.00001 ACM 88 1 J 30 11.0 1706 0640 0742 21.7 22.0 24 P127 6498 6498 555 -0.00003 ACM 89 1 R 27 10.1 1706 0934 1031 21.5 21.9 24 P127 6498 6498 555 +0.00001 ACM 90 1 88 23 12.8 1706 1430 1530 21.5 22.0 24 P127 6500 6499 556 +0.00000 KLL 91 1 B 21 11.4 1706 1531 1620 22.0 22.0 24 P127 6500 6498 556 -0.00002 KLL Ran with Sta 090 92 1 A 18 12.0 1706 1807 1843 21.4 22.0 24 P127 6500 6499 556 +0.00000 KLL 93 1 4 10 11.1 1706 1843 1908 22.0 22.2 24 P127 6500 6499 556 -0.00002 KLL Ran with Sta 092 94 1 J 10 10.9 1706 2037 2107 21.4 22.0 24 P127 6503 6503 561 +0.00000 SR 95 1 E 11 9.4 1706 2108 2148 22.0 22.2 24 P127 6503 6502 561 +0.00000 SR Ran with Sta 094 96 1 3 14 12.0 1806 0230 0319 21.8 22.1 24 P127 6497 6498 550 +0.00000 KMS 97 1 R 10 9.8 1806 0319 0349 22.1 22.4 24 P127 6497 6498 550 -0.00004 KMS Cleaned cell, replaced inter-nal tubing, soaked cell in RBS; Ran with Sta 096 98 1 3 8 10.5 1906 1119 1136 23.0 23.1 24 P127 6494 6494 547 ACM Used 4 vials to initialize 99 1 A 10 8.9 1906 1137 1159 23.1 23.1 24 P127 6494 6493 547 +0.00001 ACM Ran with Sta 098 100 1 4 16 11.8 1906 1621 1656 23.1 23.6 24 P127 6493 6494 547 +0.00002 KLL 101 1 B 17 16.4 2006 0007 0042 22.8 23.3 24 P127 6493 6493 547 +0.00000 KLL 102 1 88 21 13.0 2006 0042 0123 23.3 23.1 24 P127 6493 6493 547 +0.00002 KLL Ran with Sta 101 103 1 R 27 9.6 2006 0143 0239 23.0 23.3 24 P127 6493 6493 547 +0.00002 ACM 104 1 J 29 10.0 2006 0605 0703 22.8 23.3 24 P127 6493 6493 547 +0.00002 ACM 105 1 E 29 9.6 2006 0936 1035 22.9 23.6 24 P127 6491 6491 545 +0.00002 ACM 106 1 R 28 10.7 2006 1610 1704 22.4 22.6 24 P127 6492 6492 546 -0.00001 KLL 107 1 J 28 11.2 2006 2044 2143 22.2 22.5 24 P127 6493 6492 546 -0.00003 KLL 108 1 E 29 12.1 2106 0208 0309 22.1 22.7 24 P127 6493 6493 546 +0.00001 ACM 109 1 R 30 10.2 2106 0551 0652 22.4 23.0 24 P127 6493 6493 546 +0.00001 ACM 110 1 J 30 9.5 2106 0944 1052 22.8 23.2 24 P127 6492 6492 545 -0.00000 KMS 111 1 E 27 9.9 2106 1443 1557 23.5 23.9 24 P127 6490 6489 541 +0.00000 SWR 112 1 R 27 8.2 2106 1807 1903 23.5 23.7 24 P127 6489 6490 542 -0.00002 KLL 113 1 J 26 9.3 2206 0613 0710 22.7 23.0 24 P127 6491 6490 542 +0.00002 ACM 114 1 R 24 9.0 2206 1044 1131 23.5 23.6 24 P127 6490 6490 542 +0.00003 ACM 115 1 3 22 9.7 2206 1532 1617 22.7 22.9 24 P127 6490 6491 542 -0.00002 KLL 116 1 A 23 8.0 2206 1843 1932 22.3 22.5 24 P127 6491 6492 543 -0.00002 KLL 117 1 B 19 12.5 2306 0258 0334 22.7 22.8 24 P127 6492 6492 543 +0.00000 ACM 118 1 88 12 10.1 2306 0334 0401 22.8 23.0 24 P127 6492 6492 543 +0.00003 ACM Ran with Sta 117 119 1 E 31 11.5 2306 0952 1058 22.6 23.0 24 P127 6492 6491 543 -0.00000 KMS 120 1 J 31 11.9 2306 1411 1505 22.4 22.8 24 P127 6493 6492 543 +0.00002 KLL 121 1 R 29 11.2 2306 1840 1936 22.6 23.0 24 P127 6491 6492 542 +0.00002 KLL 122 1 E 29 11.5 2406 0013 0110 22.4 22.9 24 P127 6493 6491 542 +0.00001 ACM 123 1 J 31 10.6 2406 0438 0540 22.6 22.9 24 P127 6491 6491 542 +0.00001 ACM 124 1 R 31 9.7 2406 0912 1014 22.6 23.1 24 P127 6493 6492 542 +0.00002 ACM 125 1 E 29 9.8 2406 1413 1506 23.0 23.2 24 P127 6490 6491 541 +0.00004 KLL 126 1 J 30 9.5 2406 1823 1918 23.1 23.6 24 P127 6490 6490 541 +0.00002 KLL 127 1 R 30 10.3 2506 0013 0111 23.1 23.5 24 P127 6492 6491 541 +0.00001 ACM 128 1 E 27 10.7 2506 0451 0541 23.2 23.6 24 P127 6490 6491 541 +0.00003 ACM 129 1 J 30 9.4 2506 0910 1008 23.1 23.6 24 P127 6489 6489 539 +0.00002 ACM 130 1 R 29 10.4 2506 1510 1603 23.5 23.9 24 P127 6490 6490 540 +0.00002 KLL 131 1 E 29 10.5 2506 2051 2145 23.9 24.3 24 P127 6489 6490 539 +0.00004 KLL 132 1 J 27 10.6 2606 0129 0222 23.8 24.1 24 P127 6488 6487 537 +0.00000 ACM 133 1 R 28 9.1 2606 0502 0554 23.8 24.1 24 P127 6490 6489 539 +0.00002 ACM 134 1 E 27 8.8 2606 0929 1020 23.9 24.3 24 P127 6489 6490 539 +0.00002 ACM 135 1 B 24 8.8 2606 1343 1430 24.1 24.6 24 P127 6489 6489 539 +0.00003 KLL 136 1 3 24 8.8 2606 1804 1849 24.6 25.0 24 P127 6490 6489 539 +0.00002 KLL 137 1 J 25 8.4 2606 2144 2232 24.7 25.1 24 P127 6488 6488 538 +0.00004 KLL 138 1 A 22 8.4 2706 0144 0228 24.3 24.7 24 P127 6489 6489 538 +0.00003 ACM 139 1 B 18 10.6 2706 0807 0839 24.2 24.4 24 P127 6488 6489 538 +0.00000 ACM 140 1 3 18 8.1 2706 0840 0913 24.4 24.5 24 P127 6488 6488 538 +0.00002 ACM Ran with Sta 139 141 1 A 20 8.4 2706 1237 1320 24.3 24.6 24 P127 6489 6489 539 +0.00002 KLL 142 1 88 23 8.8 2706 1552 1633 24.5 24.9 24 P127 6488 6488 538 +0.00002 KLL 143 1 3 21 8.4 2706 1849 1929 24.8 24.6 24 P127 6488 6488 538 +0.00003 KLL 144 1 B 24 8.6 2706 2229 2315 24.1 24.4 24 P127 6488 6488 538 +0.00002 KLL 145 1 E 26 10.4 2806 0410 0500 23.8 24.1 24 P127 6489 6488 538 +0.00002 ACM 146 1 R 27 10.2 2806 0756 0848 23.7 24.1 24 P127 6488 6488 538 +0.00001 ACM 147 1 A 24 9.8 2806 1029 1113 23.7 24.1 24 P127 6490 6490 540 +0.00003 ACM Ran DI through the system, standardization came out the same 148 1 88 20 9.3 2806 1334 1412 23.7 24.0 24 P127 6491 6490 540 +0.00003 KLL 149 1 B 22 8.9 2806 1614 1655 23.7 24.0 24 P127 6489 6490 540 +0.00002 KLL 150 1 3 19 10.4 2806 2040 2116 23.6 24.0 24 P127 6490 6490 540 +0.00002 KLL 151 1 A 17 15.4 2906 0446 0518 23.4 23.8 24 P127 6490 6489 540 +0.00000 ACM 152 1 88 17 13.3 2906 0518 0553 23.8 23.7 24 P127 6490 6490 540 +0.00002 ACM Ran with Sta 151 153 1 J 3 12.1 2906 0555 0601 23.7 23.8 24 P127 6489 6489 540 +0.00000 ACM 153 2 B 15 10.4 2906 0602 0632 23.8 23.9 24 P127 6489 6489 540 +0.00001 ACM Ran with Sta 153 Cast 1 Table 1.10.0 WOCE A24 per-box salinometer lo 1.11. Oxygen Analysis Samples were collected for dissolved oxygen analyses soon after the rosette sampler was brought on board and after CFC and helium were drawn. Nominal 125 ml volume- calibrated iodine flasks were rinsed twice with minimal agitation, then filled via a drawing tube and allowed to overflow for at least 3 flask volumes. The sample temperature was measured with a small platinum resistance thermometer embedded in the drawing tube. Draw temperatures are useful in detecting possible bad trips even as samples were being drawn. Reagents were added to fix the oxygen before stoppering. The flasks were shaken twice; immediately after drawing, and then again after 20 minutes, to assure thorough dispersion of the MnO(OH)2 precipitate. The samples were analyzed within 4 hours of collection. Dissolved oxygen analyses were performed with an SIO designed automated oxygen titrator using photometric endpoint detection based on the absorption of 365 nm wavelength ultra-violet light. Thiosulfate was dispensed by a Dosimat 665 buret driver fitted with a 1.0 ml buret. ODF uses a whole-bottle modified-Winkler titration following the technique of Carpenter [Carp65] with modifications by Culberson et. al [Culb91], but with higher concentrations of potassium iodate standard (approximately 0.012N) and thiosulfate solution (50 gm/l). Standard solutions prepared from pre-weighed potassium iodate crystals were run at the beginning of each session of analyses, which typically included from 1 to 3 stations. Several standards were made up during the cruise and compared to assure that the results were reproducible, and to preclude the possibility of a weighing error. Reagent/distilled water blanks were determined to account for oxidizing or reducing materials in the reagents. No preservative was added to the thiosulfate. The auto-titrator generally performed very well. The samples were titrated and the data logged by the PC control software. The data were then used to update the cruise database on the Sun SPARCstations. Blanks, and thiosulfate normalities corrected to 20°C, calculated from each standardization, were plotted versus time, and were reviewed for possible problems. New thiosulfate normalities were recalculated after the blanks had been smoothed. These normalities were then smoothed, and the oxygen data were recalculated. Oxygens were converted from milliliters per liter to micromoles per kilogram using the in-situ temperature. Ideally, for whole-bottle titrations, the conversion temperature should be the temperature of the water issuing from the bottle spigot. The sample temperatures were measured at the time the samples were drawn from the bottle, but were not used in the conversion from milliliters per liter to micromoles per kilogram because the software was not available. Aberrant drawing temperatures provided an additional flag indicating that a bottle may not have tripped properly. Oxygen flasks were calibrated gravimetrically with degassed deionized water (DIW) to determine flask volumes at ODF's chemistry laboratory. This is done once before using flasks for the first time and periodically thereafter when a suspect bottle volume is detected. All volumetric glassware used in preparing standards is calibrated as well as the 10 ml Dosimat buret used to dispense standard Iodate solution. Iodate standards are pre-weighed in ODF's chemistry laboratory to a nominal weight of 0.44xx grams and the exact normality is calculated at sea. Potassium Iodate (KIO3) is obtained from Johnson Matthey Chemical Co. and is reported by the suppliers to be > 99.4% pure. All other reagents are "reagent grade" and are tested for levels of oxidizing and reducing impurities prior to use. 3434 oxygen measurements were made. There were a few times when the data acquisition computer (PC) hung up and a sample was lost. The temperature stability of the laboratory used for the analyses was fair. No major problems were encountered with the analyses. Fifty-seven pair of replicate (ie. from the same rosette bottle) oxygen samples drawn. The standard deviation of the replicates was 0.004 ml/l. The oxygen data were used to calibrate the CTD dissolved O2 sensor. 1.12. Nutrient Analysis Nutrient samples were drawn into 45 ml high density polypropylene, narrow mouth, screw-capped centrifuge tubes which were rinsed three times before filling. The tubes were rinsed with 1.2N HCL before each filling. Standardizations were performed at the beginning and end of each group of analyses (one cast, usually 24 samples) with a set of an intermediate concentration standard prepared in low- nutrient seawater for each run from secondary standards. The secondary standards were prepared aboard ship by dilution from dry, pre-weighed primary standards. Sets of 6-7 different concentrations of shipboard standards were analyzed periodically to determine the deviation from linearity as a function of concentration for each nutrient. Nutrient analyses (phosphate, silicate, nitrate and nitrite) were performed on an ODF-modified 4 channel Technicon AutoAnalyzer II, generally within one hour of the cast. Occasionally some samples were refrigerated at 4C for a maximum of 4 hours. The methods used are described by Gordon et al. [Atla71], [Hage72], [Gord92]. The colorimeter output from each of the four channels were digitized and logged automatically by computer (PC), then split into absorbence peaks. Each run was manually verified. Silicate is analyzed using the technique of Armstrong et al. [Arms67]. Ammonium molybdate is added to a seawater sample to produce silicomolybdic acid which is then reduced to silicomolybdous acid (a blue compound) following the addition of stannous chloride. Tartaric acid is added to impede PO4 color (interference). The sample is passed through a 15 mm flowcell and the absorbence measured at 660nm. ODF's methodology is known to be non-linear at high silicate concentrations (>120 M); a correction for this non-linearity is applied in ODF's software. All silicates during this expedition were in the linear range (<100 M). Modifications of the Armstrong et al. [Arms67] techniques for nitrate and nitrite analysis are also used. The seawater sample for nitrate analysis is passed through a cadmium column where the nitrate is reduced to nitrite. Sulfanilamide is introduced, reacting with the nitrite, then N-(1-naphthyl)ethylenediamine dihydrochloride which couples to form a red azo dye. The reaction product is then passed through a 15 mm flow-cell and the absorbence measured at 540 nm. The same technique is employed for nitrite analysis, except the cadmium column is not present, and a 50 mm flow-cell is used. Phosphate is analyzed using a modification of the Bernhardt and Wilhelms [Bern67] technique. An acidic solution of ammonium molybdate is added to the sample to produce phosphomolybdic acid, then reduced to phosphomolybdous acid (a blue compound) following the addition of dihydrazine sulfate. The reaction product is heated to 58°C to enhance color development, then passed through a 50 mm flow-cell and the absorbence measured at 820 nm. Nutrients, reported in micromoles per kilogram, were converted from micromoles per liter by dividing by sample density calculated at zero pressure, in-situ salinity, and an assumed laboratory temperature of 25°C. Na2SiF6, the silicate primary standard, is obtained from Aesar, a division of Johnson Matthey Chemical Co., and is reported by the supplier to be >98% pure. Primary standards for nitrate (KNO3), nitrite (NaNO2), and phosphate (KH2PO4) are also obtained from Johnson Matthey Chemical Co. and the supplier reports purities of 99.999%, 97%, and 99.999%, respectively. 3439 nutrient analyses were performed. No major problems were encountered with the measurements. The pump tubing was changed 3 times, and deep seawater was run as a substandard on each run. The efficiency of the cadmium column used for nitrate was monitored throughout the cruise and ranged from 99.0-100.0%. The temperature stability of the laboratory used for the analyses ranged from 21 to 28°C, but was relatively constant during any one station (±1.5°C). References Arms67. Armstrong, F. A. J., Stearns, C. R., and Strickland, J. D. H., "The measurement of upwelling and subsequent biological processes by means of the Technicon Autoanalyzer and associated equipment," Deep-Sea Research, 14, pp. 381-389 (1967). Atla71. Atlas, E. L., Hager, S. W., Gordon, L. I., and Park, P. K., "A Practical Manual for Use of the Technicon AutoAnalyzer(R) in Seawater Nutrient Analyses Revised," Technical Report 215, Reference 71-22, p. 49, Oregon State University, Department of Oceanography (1971). Bern67. Bernhardt, H. and Wilhelms, A., "The continuous determination of low level iron, soluble phosphate and total phosphate with the AutoAnalyzer," Technicon Symposia, I, pp. 385-389 (1967). Brow78. Brown, N. L. and Morrison, G. K., "WHOI/Brown conductivity, temperature and depth microprofiler," Technical Report No. 78-23, Woods Hole Oceanographic Institution (1978). Carp65. Carpenter, J. H., "The Chesapeake Bay Institute technique for the Winkler dissolved oxygen method," Limnology and Oceanography, 10, pp. 141-143 (1965). Cart80. Carter, D. J. T., "Computerised Version of Echo-sounding Correction Tables (Third Edition)," Marine Information and Advisory Service, Institute of Oceanographic Sciences, Wormley, Godalming, Surrey. GU8 5UB. U.K. (1980). Culb91. Culberson, C. H. and Williams, R. T., et al., "A comparison of methods for the determination of dissolved oxygen in seawater," Report WHPO 91-2, WOCE Hydrographic Programme Office (Aug 1991). Gord92. Gordon, L. I., Jennings, J. C., Jr., Ross, A. A., and Krest, J. M., "A suggested Protocol for Continuous Flow Automated Analysis of Seawater Nutrients in the WOCE Hydrographic Program and the Joint Global Ocean Fluxes Study," Grp. Tech Rpt 92-1, OSU College of Oceanography Descr. Chem Oc. (1992). Hage72. Hager, S. W., Atlas, E. L., Gordon, L. D., Mantyla, A. W., and Park, P. K., "A comparison at sea of manual and autoanalyzer analyses of phosphate, nitrate, and silicate," Limnology and Oceanography, 17, pp. 931-937 (1972). Mill82. Millard, R. C., Jr., "CTD calibration and data processing techniques at WHOI using the practical salinity scale," Proc. Int. STD Conference and Workshop, p. 19, Mar. Tech. Soc., La Jolla, Ca. (1982). Owen85. Owens, W. B. and Millard, R. C., Jr., "A new algorithm for CTD oxygen calibration," Journ. of Am. Meteorological Soc., 15, p. 621 (1985). Owen85. Owens, W.B. and Millard, R.C., Jr., "A new algorithm for CTD oxygen calibration," Journ. of Am. Meteorological Soc., 15, p. 621 (1985) UNES81. UNESCO, "Background papers and supporting data on the Practical Salinity Scale, 1978," UNESCO Technical Papers in Marine Science, No. 37, p. 144 (1981). 2. Shipboard ADCP and LADCP Shipboard ADCP Upper ocean current measurements were made throughout the cruise using the hull- mounted acoustic Doppler current profiler (ADCP) system that is permanently installed on the R/V Knorr. The system includes five components: 1) an incoherent (narrow bandwidth, un-coded pulse) 4-beam Doppler sonar operating at 153 kHz (model VM-150 made by RD Instruments), mounted with beams pointing 30 degrees from the vertical and 45 degrees azimuth from the keel; 2) the ship's main gyro compass, continuously providing ship's heading measurements to the ADCP via a 1:1 synchro; 3) a Global Positioning System (GPS) attitude sensor (Ashtech model 3DF), which uses a 4-antenna array to provide interferometric measurements of ship's pitch, roll, and heading; 4) a GPS navigation receiver (Trimble Tasman) providing position fixes using both GPS frequency bands (L1 and L2) and the P and Y codes (military "Precision Positioning Service", or PPS); 5) an IBM-compatible personal computer running the Data Acquisition Software (DAS) version 2.48 from RD Instruments, augmented by Firing's software interrupt handler ("user exit") program "ue4", C. Flagg's user exit "agcave", and Flagg's TSR watchdog timer program. The ADCP was configured for 16-m pulse length, 8-m processing bin, and a 4-m blanking interval (all distances being projections on the vertical and based on a nominal sound speed of 1470 m/s). The transducer depth was 5 m; 60 velocity measurements were made at 8-m intervals starting 21 m below the surface. About 240 pings were sent in each 5-minute averaging interval. For each ping, velocities relative to the transducer were rotated to a geographical coordinate system using the gyro compass heading, but assuming pitch and roll to be zero. The single-ping velocities were then vector-averaged over the 5-minute ensemble. The ensemble- averaging was done separately for the vertical average from bins 2 through 10 and for the deviation of each bin from this vertical subset; the two parts were then added back together and stored. The conversion from Doppler shift to velocity was done using sound-speed calculated from the temperature measured by a sensor in the transducer, assuming a constant salinity of 35 psu. When a velocity estimate in one of the four beams was missing, velocity was calculated from the remaining three beams. In regions of shallow water, the ADCP was configured to track the bottom with one bottom-tracking ping for each water-tracking ping. This was effective to depths of 600 m or more. From the time the ship left Woods Hole to the last station of the present cruise, approximately 100 hours of underway bottom tracking data were collected. This is significant for the calibration calculations discussed below. The user exit program integrated the GPS position and attitude information into the ADCP data stream. Position fixes were recorded at the start and end of each ADCP averaging interval (5-minute ensemble). Attitude from the 3DF was sampled at each ping and edited within each ensemble. The mean, standard deviation, minimum, and maximum values of pitch, roll, and compass heading error were calculated and recorded. The compass error is the quantity of primary interest: for each ping, the compass reading used by the ADCP was subtracted from the most recent 3DF heading (updated once per second), and this difference was taken as the time-variable compass error plus some constant misalignment of the 3DF antenna array. The 3DF attitude information was not used for the real-time vector-averaging of velocity because it is not quite reliable enough; dropouts and outliers do occur. Velocity, position, and attitude measurements were post-processed using the University of Hawaii CODAS software package, generally as described by Firing in WHP Office Report WHPO 91-1, WOCE report 68/91. The essential modification since then is the rotation of the velocity measurements relative to the ship to correct for the gyro compass error as measured by the 3DF. After this correction, and a small but varying sound speed correction (not yet made at the time of this writing), standard water and bottom tracking calibration methods (Joyce, 1989; Pollard and Read, 1989) should yield two constants: a velocity scale factor, and a horizontal angular offset between the transducer and the 3DF antenna array. The angular offset is particularly important; an error of 0.1 degree leads to a cross- track bias of 1 cm/s for a ship speed of 11 kts. For the onboard data processing, these calibration factors were calculated based on bottom tracking from the transit from Woods Hole prior to the cruise and the transits to and from Cork. Water track calibration calculations based on the entire cruise (all stations--water track calibration requires ship accelerations, such as stops for stations) indicate an overall error of only 0.05 degree relative to the preliminary calibration. At present this small correction has not been applied. Closer inspection of all available calibration information indicates that the "constant" factors are measurably not constant. The angle offset factor may vary within a range of up to plus or minus 0.2 degrees. A possible cause is under investigation; it is not clear whether it will be possible to reduce this uncertainty in the present or future data sets. The quality of the shipboard ADCP data set from this cruise is exceptionally good. No instrument problems were detected; weather was mostly good and never very bad; there was an abundance of acoustic targets on the entire cruise track. The depth range was typically 400 m or more, sometimes a full 500 m, and only occasionally less than 300 m. There were no known compass failures and no long dropouts of 3DF data. The upper ocean velocity field during the cruise is summarized in a map of shipboard ADCP velocity vectors averaged from 100 to 300 m (Figure 2.0); vertical shear was weak on most of the cruise track, so this layer average is representative. The overall impression is of weak currents--usually under 50 cm/s, and mostly in the form of ubiquitous small-scale squirts and eddies. The contribution from tides and near-inertial motions has not yet been estimated quantitatively, but I believe it is a small part of what we see in Figure 2.0. The East Greenland Current stands out as a narrow jet flowing southwestward along the Greenland coast, particularly off Cape Farewell. On the northern crossing, however, it appears to have been highly convergent in the cross-track direction. The eddy field was relatively strong in the Rockall Trough and in the Iceland and Irminger basins on the section from Scotland to Greenland. Currents were mostly weak on the section from the Azores to Ireland on leg 1, and between the sub-polar front (about 50°N) and the East Greenland Current on leg 4. At and south of the sub-polar front the currents are stronger, but much of the pattern is not easy to interpret. There seem to be four main zones of eastward flow north of 40°N, some of them very narrow. There is a major southward component in the sub-polar front and at other spots between there and the Azores. Figure 2.0 A24 Shipboard ADCP velocity vectors. Lowered ADCP To measure velocity throughout the water column at each station, a self-contained ADCP was mounted on the rosette; this is referred to as the lowered ADCP (LADCP). The LADCP includes a magnetic compass and a tilt sensor, so the velocity profiles can be rotated into the local east-north-up coordinate system. Because the motion of the rosette over the ground is not measured, the LADCP measurements of current relative to the instrument cannot be used directly to infer the current over the ground. Instead, the single-ping velocity profiles are differentiated vertically to remove the package motion (which changes only slightly between the time a ping is transmitted and the time the back-scattered return is received). The vertical shear estimates from all pings are then interpolated and averaged on a single uniform depth grid covering the whole water column. This full-depth shear profile is integrated vertically to yield a velocity profile with an unknown constant of integration; and the constant is calculated from the known displacement of the instrument between beginning and end of the cast, together with the shape of the relative velocity profile and the measured current past the instrument as a function of time during the cast. The method is explained in detail by Fischer and Visbeck (1993). The instrument used on this cruise was a new 150-kHz coded pulse ("Broadband") profiler made by RD Instruments (a specially modified Phase-III DR-BBADCP), with four beams angled 30 degrees from the vertical. All but four of the 154 profiles were made with the following instrument parameters: blanking interval, pulse length, and processing bin length were all set to 16 m (projected on the vertical). Sixteen depth bins were recorded. Pings were transmitted alternately at 1 and 1.5 or 1.6 second intervals. Data from each ping was recorded individually, with no averaging. Ambiguity resolution mode 1 (no automatic resolution) was used, with an ambiguity interval of either 3 m/s or 3.6 m/s--the smaller value was used when weather was exceptionally calm. Medium bandwidth was selected. Three-beam velocity solutions were not used, and solutions with an error velocity exceeding 15 cm/s were rejected. Bin-mapping based on tilt was selected. Immediately after each station the data were dumped from the LADCP to a PC via a serial line (RS-422), and transferred to a Sun workstation for archiving and processing. The profile was processed using the University of Hawaii system, a mixture of C, Matlab, and Perl programs. Velocity and shear data are automatically edited based on several criteria including correlation magnitude (typically 70- count minimum), error velocity (10 cm/s maximum), deviation of vertical velocity in a given bin from its vertical average (5 cm/s maximum), and deviation of individual shear estimates from a mean shear profile (3.5 standard deviations). These parameters are subject to change in later processing, but the values quoted seemed reasonable and adequate for the present data set. Additional editing is done on the upcast: the top two depth bins are rejected if the current, profiler vertical velocity, and profiler orientation are such that one beam may be intersecting the profiler's wake. Depth bins subject to contamination from the side-lobe return from the bottom, or from the return of the previous ping from the bottom, are also automatically rejected. Critical to this part of the editing is accurate knowledge of the depth of the bottom and the depth of the profiler. Therefore we have an automated routine for matching the time series of vertical velocity measured by the LADCP with the time series of vertical velocity calculated from the CTD pressure record, and then assigning the corresponding CTD-derived depths to the LADCP. With these instrument depths in the LADCP database, another program scans the LADCP back-scatter amplitude profiles in the near-bottom region; the LADCP depth plus the vertical range to the amplitude maximum is the bottom depth. With a high quality and continuous CTD time series available from ODF immediately after each cast, we were able to complete the LADCP processing about 20 minutes after the end of the data transfer. Accurate position fixes at the start and end of the LADCP profile are essential to the calculation of absolute velocities. We log the PPS GPS fixes at the full 1 Hz sampling rate. The processing software accesses these files and extracts the subsets needed for each profile. Magnetic variation is needed to calculate true direction from the compass readings; we calculate the variation from a standard model of the earth's magnetic field. To date we have not, however, performed any calibration of the compass in the instrument, but have taken the compass headings at face value. As with the shipboard ADCP, and for the same reasons, the LADCP quality on this cruise is excellent. Package motion was moderate and scattering levels were good, particularly at the higher latitudes. The only instrument problem was a bizarre incident early in the cruise: at stations 2 and 3 the program usually used to communicate with the LADCP (BBSC) gradually ceased working with it. (It turns out that a similar problem was encountered by Doug Wilson at about the same time. As of this writing, no one understands what happened, given that both failures occurred with profiler/PC/program combinations that had been working normally.) A simpler alternative program (BBTALK) was completely unaffected, and was used for the remainder of the cruise. In the scramble to switch to BBTALK for station 4, the setup commands were entered by hand and something seems not to have been right-the profiler returned garbage during about the first third of the cast, then inexplicably started recording normal-looking profiles. The result is that profile 4 is incomplete at best, and probably will be neglected henceforth. A map of LADCP current vectors averaged over the full depth range of the profile (Figure 2.1) shows some characteristics of the currents as observed on this cruise. As in the shipboard ADCP data, the East Greenland Current stands out as a prominent feature amid the welter of eddies. The barotropic component of the eddy field is weakest on the Azores-Ireland section and strongest on the Scotland-Greenland section, where vertically averaged velocities of 10 cm/s or more are common. The eddy field is not well resolved by the station spacing; the velocity profiles typically change radically from one station to the next. The tidal fraction of the velocity field measured by the LADCP has not yet been estimated, but is not expected to dominate the observations in any of the more energetic regions. References Fischer, J., and M. Visbeck, 1993. Deep velocity profiling with self-contained ADCPs. J. Atmos. Oceanic Technol., 10, 764-773. Joyce, T. M., 1989. On in situ "calibration" of shipboard ADCPs. J. Atmos. Oceanic Technol., 6, 169-172. Pollard, R., and J. Read, 1989. A method for calibrating shipmounted Acoustic Doppler Profilers, and the limitations of gyro compasses. J. Atmos. Oceanic Technol., 6, 859-865 Figure 2.1 A24 Map of LADCP current vectors. 3. CFC-11 and CFC-12 Sample Collection Water samples were collected using 10 liter Niskin bottles which were cleaned for CFC analysis. All O-rings of the Niskin bottles (end cap O-rings and spigot O- rings) were baked in a vacuum oven to remove CFCs. CFC samples were drawn from 10 to 31 Niskin bottles per station, depending on bottom depth or station spacing. 100 ml precision groundglass syringes with Luer-lock fittings were used to draw water samples from the Niskin bottles. Vacuum-baked syringe valves were used, and were replaced whenever there was a suspicion of contamination or leakage. In general, sampling for CFC analysis was done at every station alternating fulldepth sampling and partial-depth sampling depending on the measurement progress of the previous station's samples. The partial depth sampling was planned according to the CFCs results readily available from previous stations as well as from the CTD profiles. A total of 2085 water samples from 132 CTD stations were measured, including approx. 70 duplicate pairs used to estimate measurement precisions. The shipboard CFC values will be finalized after a few minor blank corrections and a stripper efficiency correction for CFC-11 in the lab. Typical stripping efficiency of CFC-11 in various water temperature during this cruise is approx. 99.3%. Air samples were collected by Air Cadet pump through intake lines of 3/8" OD Decabon tubing from inlets at the bow and stern of the vessel. The bow side air intake was mostly used during this cruise. 107 air samples were measured to estimate current atmospheric CFC concentrations and to calculate the surface water CFC saturation conditions. Three or four replicate air samples were measured at each location to obtain reliable numbers. Equipment and Technique The chlorofluorocarbons CFC-11 and CFC-12 were measured by an ECD-GC (electron capture detector equipped gas chromatograph system), as described by Bullister and Weiss (1988), with slight modifications. Gas samples, dry air or standard gas, were injected onto a cold trap (-30°C) for concentration. Approximately 30 cc of seawater from collected samples was introduced into a glass stripping chamber where the dissolved gases were purged with purified gas, and the evolved CFCs were concentrated using the same cold trap. The trap was subsequently isolated and heated (100°C), so that the evolved CFCs could be transferred into a pre-column (15 cm of Porasil-C) and then a chromatographic separating column (3 m of Porasil C) held at 70°C in the GC oven. The ECD was operated at 250°C. The analysis of all water samples was completed within 3 to 7 hours of the water coming on board. Typical standard gas and water sample chromatograms are shown in Figures* 1a and 1b. The data acquisition, peak integration and calculation were carried out by a Sun Microsystems computer with an HP35900 chromatographic interface. Calibration The CFC-11 and CFC-12 analyses were calibrated over the concentration range of the samples, using calibration curves made by injections of fixed volumes of standard gas filled to various pressures as measured by a precision quartz pressure transducer (Paro-scientific 740). Using polynomial curves fitted to the calibration points, the corrected peak areas were converted into molar concentrations. The standard gas was prepared at the Scripps Institution of Oceanography (SIO) and was calibrated on the SIO 1993 scale. Preliminary Results CFC-11 and CFC-12 were near saturation in surface waters, and deep and bottom waters of the North Atlantic Ocean basins are in general well ventilated unlike the Indian or Pacific Ocean where deep basins are mostly filled with low CFC or CFC- free waters. The lowest CFC content water was observed in the North-Eastern Atlantic Basin in the LEG-1 (Azores to Ireland) toward the north below 3000-4000 m (CFC-11: less than 0.04 pmol/kg). Typical CFCs profiles from different basins are shown in Figures* 2a, 2b and 2c to show dynamic and spatially heterogeneous features of the North Atlantic Ocean. Well known bottom and deep water features such as overflow waters and the Labrador Sea Water were clearly resolved by CFCs distributions. High CFC-content Denmark Strait Overflow Water (DSOW) was observed in the Irminger Basin (LEG-3) and on the Eirik Ridge south of Greenland (LEG-4). The other high CFC-content overflow water, Iceland-Scotland Overflow Water (ISOW), was observed on the eastern flank of the Reykjanes Ridge in the Iceland Basin and on the western side of the ridge in the Irminger Basin (LEG-3). The low salinity, high CFC and high oxygen content Labrador Sea Water (LSW) was observed at about 1500-2000 m depth range in nearly every survey section. The CFC concentration of the LSW core layer was highest (CFC-11: ~4 pmol/kg) on the Eirik Ridge, Greenland (LEG-4) and in the Irminger Basin, and progressively became lower toward the west and south. The CFC-11 concentration of the LSW core layer observed in the North- Eastern Atlantic Basin (LEG-1) was as low as 1.5-2.0 pmol/kg. The mid-depth low CFCs, low oxygen and high salinity water originated from the Mediterranean Sea was observed in the Azores-Ireland (LEG-1) section, in the southern Rockall Trough (LEG-2) section, and the southern part of the Greenland-Azores (LEG-4) section at approx. 1000 m depth. Thick and relatively homogeneous Subpolar Mode Water with high CFC concentration was well developed in the upper few hundred meters in the northern part of the survey area. The highest CFC concentration surface water was generally found in the Eastern Greenland Current area. Near 0 C cold surface water near the Angmassalik, Greenland (LEG-3) showed the highest CFC concentration (CFC- 11: as high as 6.83 pmol/kg). The CFC-11 contour sections from the four legs of this expedition in the subpolar North Atlantic Ocean are shown in Figures* 3a-d. Reference Bullister, J. L., and R. F. Weiss. 1988. Determination of CCl3F and CCl2F2 in seawater and air. Deep-Sea Research, 35: 839-853. 4. Alkalinity Dr. Frank J. Millero's University of Miami group measured Total Alkalinity (TA) using a potentiometric titration system for the WOCE/ACCE North Atlantic A24 research cruise aboard the R/V Knorr. Two systems were operated, each consisting of a Metrohm 665 Dosimat titrator, an Orion pH meter, a fixed volume closed plexiglass cell, and a PC. During the transit from Woods Hole, MA to Ponta Delgada, Azores, 300 underway samples were collected from the flowing seawater line. The samples were taken every half an hour, with additional salt samples collected from the flowing line once daily for comparison with the TSG data. The transit from west to east showed a decline in TA normalized to salinity (NTA), with values ranging from approximately 2400 to 2280 mmol/kg. Some interesting features were observed in the rapid change intervals of mixing water between roughly 63°W to 53°W, as well as, a peak in the NTA at 44°W. The next leg of the cruise departing from the Azores was a repeat of a previous cruise track from the Fall of 1996. 153 CTD stations were carried out to depth to give a hydrographic profile of the cruise transects. Alkalinity followed the TCO2 group's sampling strategy, where at every other station, a full CTD cast was sampled. Surface duplicates were sampled on the stations in between. This sampling strategy was chosen due to the time involved in analyzing the samples versus station spacing. Comparisons between the Fall 96 cruise and this Summer 97 cruise show some slight seasonal shifts in salinity, temperature, and TA. Upon finishing the rectangular cruise track in the North Atlantic offshore of the Azores, underway samples were again collected during the transit to Halifax, Nova Scotia. 114 TA samples were collected every hour during the last transit, while salts were collected every 6 hours for comparison to the TSG data. The transit from east to west showed an increase in NTA, with values ranging from approximately 2280 to 2360 mmol/kg. The sea surface temperature reported almost 10°C higher than the data collected at the latitudes further south. Interesting features were again observed in that the mixing waters beginning around 47°W, with the peak in NTA previously observed at 44°W, drastically decreased at the higher latitude. 5. CO2 6. Helium, Tritium and 18O Sample Collection Water samples for later analysis of helium, tritium and 18O were collected from 10 litre Niskin bottles. The strategy was to sample the entire water column with emphasis on Labrador Sea Water and the Overflow waters. In particular, we extensively sampled the east Greenland Shelf and Slope. 607 Helium samples, 596 Tritium samples, and 367 18O samples were collected at 43, 42 and 37 stations respectively. Since samples for 18O measurement will also be drawn from the tritium samples, the total number of samples available for 18O analysis is 963. Water samples for Helium analysis were collected in stainless steel cylinders with rotating plug valves on both ends. The cylinder was attached to the spigot on the Niskin by tygon tubing. When not in use, the tubing was kept soaked in a bucket of seawater to keep it conditioned. Tritium samples were collected in 1 litre glass bottles. The bottle caps were then secured using insulation tape. 18O samples were collected in 30 ml glass bottles. Bottle caps were secured similarly. Equipment Samples collected in the cylinders were processed on board for Helium. This was done using the "at sea extraction system" provided by W.J. Jenkins of the WHOI Helium Isotope Lab (Jenkins, 1992). The extracted Helium was collected in 30 ml glass bulbs, which were subsequently flame-sealed. All samples will be analysed mass-spectrometrically at the Lamont-Doherty Earth Observatory. Helium and Tritium samples will be analyzed in the Noble Gas Lab using techniques described in Bayer (1989). 18O samples will be analyzed in the Stable Isotope Lab. References Bayer, R., Schlosser, P., Bonisch, G., Rupp, H., Zaucker, F., and Zimmek, G., 1989. Performance and blank components of a mass spectrometric system for routine measurement of helium isotope and tritium by the 3He ingrowth method. Sitzungsberichte der heidelberger Akademie der Wissenschaften, Mathematisch- naturwissenschaftliche Klasse. Jenkins, W. J., 1992. ASEX User's Manual: Documentation on procedures, software and hardware for the At Sea Extraction System, version 2.0. Woods Hole Oceanographic Institution. Appendix A Bottle Quality Comments All data comments per PI's request from WOCE A24 ACCE. Investigation of data may include comparison of bottle salinity and oxygen data with CTD data, review of data plots of the station profile and adjoining stations, and rereading of charts (i.e., nutrients). Comments from the Sample Logs and the results of ODF's investigations are included in this report. Units stated in these comments are degrees Celsius for temperature, Practical Salinity Units for salinity, and unless otherwise noted, milliliters per liter for oxygen and micromoles per liter for Silicate, Nitrate, and Phosphate. The first number before the comment is the cast number (CASTNO) times 100 plus the bottle number (BTLNBR). Station 001 Cast 1 Salinity samples are all from rerunning the samples. An error was made in transferring the data. No printouts were made of the data before the transfer. NO3 appeared low, shallow, when plotted vs. pressure. Bottom NO3 appeared high, O2 high compared with adjoining stations. No analytical problem found. N:P ratio acceptable. 107 Salinity is low compared to CTD. No analytical problem found. Salinity is acceptable. 106 Sample Log: "Leak from bottom end cap." Oxygen as well as other samples are acceptable. Salinity was lost, see Cast 1 salinity comment. 104 Salinity was lost, see Cast 1 salinity comment. Pressure is 808db. 103 Sample Log: "Bottom end-cap leak when vent cracked." Oxygen is high. Other samples appear to be acceptable. Footnote O2 bad. Pressure is 908db. 102 Salinity is high compared to CTD. No analytical problem found. Salinity is acceptable. 101 Salinity is high compared to CTD. No analytical problem found. Salinity is acceptable. 101-120 CTD upcast had to be used. Therefore, CTDO lost. Station 002 Cast 1 Console Ops: "Changed to CTD 5, because of prim temp offset on sta 001." Salinity file was lost during computer transfer. Fortunately, a duplicate set of salinity samples were drawn and eventually run. The data that is reported is the second drawn samples. 124 Oxygen: "Flask 1453 may have a calibration problem." Oxygen data is acceptable. 114 Salinity is high, nutrients are low, oxygen appears to be okay. Footnote bottle leaking, samples bad. 107 Oxygen: "Flask 1408 may have a calibration problem." Oxygen is acceptable. 103 Sample Log: "Bottom cap leaking." Oxygen is low. Other data are acceptable. Footnote bottle leaking and oxygen bad. Station 003 124-125 Sample Log: "Not closed, pylon is advanced 2 places as it should be." So the first attempt at tripping bottle 14 did not work. These bottles were not suppose to be closed. Comments on Sample Log confirm suspicion of proper bottle closure. Cast 1 Sample Log: "Tripping problem." Console Ops: "No confirm, 1 push on 14, 2 No confirms." One level was missed (600 desired depth), but that was because of an operator error. Console operator did not realize the No confirm message and had the winch operator come up to next tripping depth. Data are correct as pressure assigned. 123 Sample Log: "Vent not closed." Oxygen as well as other samples are acceptable. 116 PO4 appears 0.04 high. Nutrient analyst could not find any analytical problems. PO4 is acceptable. 114-123 Bottles did not trip as scheduled. Data appear acceptable as trip levels reassigned. See Cast 1 comments. 112 Salinity indicates a large delta-S with CTD. Gradient area, salinity appears to be okay. 108 Sample Log: "Vent not closed." O2 is high. Other samples are acceptable. Footnote bottle leaking, oxygen bad. 105 Oxygen is low compared to adjoining stations and CTDO. No analytical problems noted. Feature is not seen in other parameters. Footnote oxygen questionable. 103 Sample Log: "Bottom seal leaks." Salinity is ~0.020 low. Footnote salinity bad. Oxygen as well as other samples are acceptable. 101-102 Sample Log: "May have bubbled nitrogen through the valve." Oxygen as well as other samples are acceptable. Station 004 123 Sample Log: "Vent was open." Oxygen as well as other samples are acceptable. 120 O2 is high, nutrients are low. Salinity agrees with the CTD. Data are acceptable. O2 does not agree with adjoining stations. Footnote o2 bad. 114 Oxygen minimum, but nutrients are also low. Nutrient Analyst: "No analytical problems found." 111 Delta-S at 1122db is -0.0062. No analytical problems noted. Salinity is acceptable. 108 Sample Log: "Leaker." O2 appears to be acceptable. Delta-S at 1536db is 0.006. Salinity is high. No analytical problems noted. Footnote salinity bad. 105 Salinity is ~0.006 high. No analytical problems found. Footnote salinity bad per PI review notes. 103 Sample Log: "New bottle." O2 as well as other samples are acceptable. Station 005 111 Salinity large delta with CTD. Gradient area. Other samples are acceptable. Density inversion with this salinity, therefore salinity probably not real. Footnote salinity bad. 106 Salinity high compared with CTD. Autosal diagnostics indicate 4 tries to get a good reading. Gradient area, salinity minimum. Variation in CTD trace. Salinity is acceptable. 103 Sample Log: "Vent left open." O2 as well as other data are acceptable. Station 006 128 Sample Log: "Not closed." Okay, not suppose to be. Cast 1 Console Ops: "Duplicate No Confirm on 11, No confirm, retrip on 22." One level was missed (1500 desired depth). Data are correct as pressure assigned. 124 Oxygen is high and nutrients low, salinity is acceptable when compared to adjoining stations. N:P ratio is good. Data are acceptable. 113 Salinity is low, oxygen and nutrients high. N:P ratio is good. Data are acceptable. 111-127 See Cast 1 comments. Footnote bottle did not trip as scheduled. Data are acceptable as pressure for trip levels assigned. 109 Sample Log: "Salt bottle thimbles don't fit." Salinity is acceptable. 104 Oxygen: "Late start." Oxygen is acceptable. 103 Salinity bottle had a loose thimble. Salinity is a little low. Footnote salinity questionable, out of WOCE spec. 101 Sample Log: "Vent not closed." Oxygen as well as other data are acceptable. Autosal diagnostics indicate 4 tries before getting readings to agree. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 007 Cast 1 Console Ops: "2 No confirms, 1 push on 2, 2 No confirm 1 confirm on 12, 2 No confirm 1 confirm on 19, 2 No confirm 1 confirm on 20. One level was missed (3800 desired depth). Data appear acceptable as trip levels reassigned. 119 Sample Log: "Vent open." Oxygen as well as other data are acceptable. 117 PO4 ~0.06 high, so is SiO3 high. Nutrient analyst: "No analytical problem found, peaks, calcs look okay, normal n:p." 111 SiO3 a little high. Nutrient analyst: "No analytical problem found, peaks, calcs look okay." 110 SiO3 ~1.0 high. Nutrient analyst: "No analytical problem found, peaks, calcs look okay." 102-127 See Cast 1 comment. Footnote bottle did not trip as scheduled. Station 008 Cast 1 No comments on the Sample Log. Console ops: "2 No confirm, 1 confirm on 12, 2 No confirm, 1 confirm on 17. No levels were missed and bottles tripped on the confirm signal. 125 Nutrients low, O2 high, salinity agrees with adjoining stations. Nutrient analyst: "N:P normal, no analytical problem found." 109-110 Oxygen appears low compared to adjoining stations, agrees with CTDO. Oxygen is acceptable. Station 009 Cast 1 No comments on the Sample Log. Console Ops: "Retripped 5." No levels were missed and bottles tripped on the confirm signal. 116 O2 looks high, but is okay, agrees with CTDO. Salinity gradient area acceptable. NO3 maybe 0.4 high, PO4 0.04 high. Nutrient Analyst: "Peaks okay, calculation okay. No problem noted. This peak is higher than adjacent peaks. Could be real." 106 Autosal diagnostics had the sample run 6 times. This bottle gave analyst trouble last time it was used. This time it caused a problem with the data. Footnote salinity bad. Salinity bottle removed from box and replaced with a new bottle. 105 Oxygen is ~0.04 low. No analytical problems noted. Footnote oxygen questionable. 102-105 PO4 slightly low. Nutrient analyst: "No analytical problems found, N:P same as Sta 008." 101 SiO3 high. Nutrient analyst: "No analytical problems found." Station 010 Cast 1 No comments on the Sample Log. 128 Sample Log indicates that no salinity was drawn, but there is a sample and it appears to be acceptable. 129 No salinity sample drawn, only TCO2. 126 Sample Log indicates that no salinity was drawn, but there is a sample and it appears to be acceptable. 125 Had trouble getting two reading to agree, but agrees fairly well for shallow value with the CTD. 124 Oxygen appears high, flask 1308. Data are acceptable. 116 Salinity low compared with CTD. No analytical problem found. Gradient area. Agrees fairly well with adjoining stations. 101 Salinity about 0.003 high. No analytical problem found. Footnote salinity bad. Station 011 Cast 1 Console Ops: "SBE pylon changed into rosette trip 1: 3 false confirms, manually fired after resetting." No levels were missed and bottles tripped on the confirm signal. Bottles were tripped as console operator had expected. 126 Nutrients high, oxygen low. Data are acceptable. Salinity agrees with adjoining stations. 121 Nutrients were not drawn. This was an error in sampling, they should have been drawn. Footnote nutrients lost. 116 Nutrients were not drawn. This was an error in sampling, they should have been drawn. Footnote nutrients lost. 105 Sample Log: "Anomalous O2 draw temp." Salt way high. Suspect bottle tripped on the way down between 300 and 400 db. Footnote bottle did not trip as scheduled, samples bad. 104 Bottle tripped at deepest level by request of console operator through the pylon trip box. 101 O2 is a little low. SiO3 high. Nutrient analyst: "No analytical problem found." Station 012 120 Salinity is high compared with CTD. PI: "Okay." 116 Oxygen: "During titration, PC froze up, sample lost." 115-120 PO4 low, NO3 low in this range. Nutrient analyst: "Could be low, N:P a little high, but hard to tell. No analytical problem noted." 114 Salinity has a large difference with the CTD agrees with adjoining stations. Salinity is acceptable. 111 O2 high, nutrients low. Data is acceptable. 108 Sample Log: "Leaky vent." Oxygen as well as other data are acceptable. Station 013 119 Sample log: "Vent not closed." Oxygen as well as other data are acceptable. 110 PO4 appears high. Nutrient analyst: "NO3 higher here, too. N:P looks about right. 107 Salinity does not agree with CTD. No analytical problem found. Oxygen appears slightly low. Gradient area. Other samples appear to be acceptable. 101 SiO3 low. Nutrient analyst: "No analytical problem found." Station 014 Cast 1 Tripping problem. CTD tripping diagnostics indicated that bottle 5 did not trip, console operator then tried to fire the bottle but instead bottle 6 closed. Data are correct as pressure is assigned. 108 Sample log: "Leaking from vent." Oxygen as well as other samples are acceptable. 105 Console Ops: "Retripped, confirmed." Sample log: "Didn't close." Bottle did not close, but CTD data the same as bottle 6 is included to give users an additional flag that there was a slight problem, but it has been properly resolved. 102 Salinity ran 4 times, loose thimble. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 015 Cast 1 Sample Log: "No surface sample." 132 Surface CTD data included for data users convenience. 130-131 Bottles did not trip as scheduled. They tripped one level shallower than planned. 128 Console Ops: "One no confirm, then confirm." Bottle tripped as scheduled. 129 Sample Log: "Didn't close." Only the CTD data is included. 110 Salinity is a little high compared with CTD. No analytical problems found. Different water from adjoining stations. 109 Salinity is a little high compared with CTD. No analytical problems found. Different water from adjoining stations. Oxygen high and nutrients low (NO3, SiO3, PO4) 108 Salinity is a little high compared with CTD. No analytical problems found. Different water from adjoining stations. Oxygen is low; could be Labrador Sea Waters. 102-108 The oxygen appears lower than adjoining stations. However SiO3 seems to follow that same pattern. Station 016 Cast 1 No comments on the Sample Log. Nutrient analyst double checked entire SiO3 profile. 126 Autosal diagnostics indicate 4 tries to get a good reading. Salinity is high compared with CTD. Variation is CTD trace, difference between the down and up. PI: "Salinity is acceptable." 123 Salinity is high compared with CTD. No analytical problem noted. Salinity is acceptable. 118 Salinity is low compared with CTD. No analytical problem noted. Salinity is acceptable. PI: "High gradient region." 114 Salinity is high compared with CTD. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. Footnote salinity bad. 112 Oxygen may be low as compared to CTDO. No analytical reason noted for low oxygen. Feature does not show in other properties or adjoining stations. PI: "This is okay, just the most extreme Labrador Sea water in the section." 111 Oxygen appears high. No analytical reason noted. Feature does not show in other properties or adjoining stations. Oxygen agrees with CTDO. Oxygen is acceptable. See 112 PI comment. 110 Salinity is high compared with CTD. No analytical problem noted. Gradient area. Salinity is acceptable. 101 Salinity is high compared with CTD. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. Footnote salinity bad. Station 017 120 Sample Log: "Lanyard hung, leaking." Salinity is high compared with CTD. No analytical problems found. Oxygen as well as other parameters appear to be acceptable. There is a large change in salinity between the down up, salinity may also be acceptable. 119 Sample Log: "O2 flask 1403 broke, replaced by 1515." 112 Sample Log: "Lanyard hung, leaking." Salinity is high compared with CTD. No analytical problems found. Nutrients and oxygen are a little low. Footnote bottle leaking, samples bad. 109 Console Ops: "10th light on." 107 Console ops: "No FF08, 7 light on." 108 Sample Log: "Was open, didn't close." Console Ops: "FF10 9th light on." Bottle did not close, but CTD data the same as bottle 7 is included to give users an additional flag that there was a slight problem, but it has been properly resolved. 106-111 NO3 appears low, SiO3 low and O2 high. Nutrient Analyst: "No analytical problem noted, different water perhaps." Station 018 124 Oxygen high and nutrients (NO3, SiO3,PO4) low 119 Salinity is higher than CTD. No analytical problem found. Feature in CTD which gives a large Delta-S. Salinity is acceptable. Other data also okay. 109 Console Ops: "Off by 1." Bottle tripped after 10, footnote bottle did not trip as scheduled. Data are acceptable. Bottle tripped before 09, the pylon was manually positioned and the bottle tripped as planned. 110 Console Ops: "Manual position." Sample Log: "Leaking from end cap." Oxygen as well as other data are acceptable. Bottle tripped before 09, the pylon was manually positioned and the bottle tripped as planned. 108 Console Ops: "No confirm, then confirm." Station 019 Cast 1 No comments on the Sample Log. 127 Oxygen: "PC locked up, lost sample." 120 NO3 and PO4 appear high. Nutrient Analyst: "Gradient here, probably real." 119 Salinity is high compared with CTD. No analytical problem found. Oxygen is high. NO3 and PO4 also appear high. Nutrient Analyst: "Gradient here, probably real." 107 Salinity analyst switched to 8 before finishing 7. All conductivity ratios were remembered and written down. 101 SiO3 low. Nutrient analyst: "No analytical problem found. Agrees with 102 and 103 which it should." Data are acceptable. 101-131 Power failure on down cast--not recoverable. CTDO lost. Noticed that there was a power failure on the deck unit at 2400db, brought CTD up to 1500 then back down. Station 020 124 Salinity is high compared with the CTD. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. Salinity agrees with adjoining stations. Offset as much as station profile 100-700 db. 121 Salinity is high compared with the CTD. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. Salinity agrees with adjoining stations. 119 Salinity is high compared with the CTD. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. PI: "Could be okay, high variability region." CTD profile indicates changing area. Down/up differences. Salinity is acceptable. 116 Salinity is low compared with the CTD Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. Agrees with Station 019. Salinity is acceptable. 108 Sample Log: "Vent not fully closed." Oxygen as well as other samples appear to be acceptable. 104 Salinity is high compared with the CTD. Autosal diagnostics indicate 3 tries to get a good reading, indicating a problem with the samples. Also high compared with adjoining stations. Footnote salinity bad. 101 Oxygen high. No analytical problem noted. Footnote oxygen bad. Station 021 Cast 1 SiO3 ~0.6 high. Nutrient analyst: "No analytical problem noted." SiO3 is acceptable. 104 Console Ops: "Manually positioned with software to 4, no affect. Dialed up 4 on deck unit and pushed button, bottle closed. This occurred with the rosette at the surface." Sample Log: "Surface bottle." 112 Salinity is high compared with the CTD. Autosal diagnostics indicate 3 tries to get a good reading. Variation in CTD trace. PI: "Salinity is acceptable." 107 Salinity is high compared with the CTD. Autosal diagnostics indicate 3 tries to get a good reading, indicating a problem with the samples. Footnote salinity bad. Station 022 Cast 1 No comments on the Sample Log. 130 PO4 ~0.4 high. Nutrient analyst:" High surface gradient here." Data are acceptable. 124 Oxygen ~0.2 high. No analytical problems noted. Footnote oxygen bad. 123 Oxygen ~0.3 high on station profile. No analytical problems noted. Oxygen agrees with CTDO. Oxygen is acceptable. 122-124 Nutrients appear low, oxygen appears high. Salinity agrees with CTD. Suspect this is real feature. Data are acceptable. 105-108 Nutrients appear low, oxygen appears high. Salinity agrees with CTD. Suspect this is real feature. Data are acceptable. 102 Several tries to get two readings to agree. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 023 Cast 1 No comments on the Sample Log. 116 Salinity is low compared to CTD. Salinity, oxygen and nutrients low. Salinity and O2 would be higher if the bottle leaked. Data are acceptable. 110 Salinity is high compared to CTD. Oxygen is a little high, nutrients are a little low. Oxygen agrees with CTDO. Data are acceptable. 105-110 SiO3 low. Nutrient Analyst: "Data are acceptable." Station 024 Cast 1 No comments on the Sample Log. 129 Oxygen is high. Other data are acceptable. Flask 1149. No analytical problems noted. Footnote oxygen questionable. 116 Salinity appears low compared to CTD. But, plotted vs Potemp, it agrees with Station 023 025 and 022. Salinity is acceptable. 113 Oxygen appears low compared with adjoining stations. No analytical problem noted. Compared vs. SiO3, oxygen appears acceptable. 109 Salinity is a little high. No analytical problem noted. PI: "High gradient." Salinity is acceptable. There is a feature in the CTD trace and a slight difference between the down and up trace. Station 025 Cast 1 Sample Log: "Forgot to remove O2 sensor cover." No CTDO sampled. 122 SiO3 appears low. Nutrient Analyst: "Large gradient in nutrients." Data are acceptable. 118 Salinity is slightly high. No analytical problem found. PI: "High gradient." Salinity is acceptable. 117-120 NO3 and PO4 are high. Nutrient Analyst: "Large gradient in nutrients." Data are acceptable. 101 Salinity is high. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. 101-131 Oxygen sensor cover left on. CTDO lost. Station 026 Cast 1 No comments on the Sample Log. 130 Oxygen appears high vs. CTDO, but agrees with adjoining stations. Oxygen is acceptable. 129 Oxygen appears low, agrees with CTDO, gradient area. Feature not seen in other data. PI: "Checked with Freon analysts, data are acceptable." 125 Oxygen appears high, agrees with CTDO, gradient area. Feature not seen in other data. PI: "Checked with Freon analysts, data are acceptable." 117 Oxygen appears high, agrees with CTDO, gradient area. Feature not seen in other data. PI: "Checked with Freon analysts, data are acceptable." 107 Salinity is high. Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Oxygen is high. Oxygen overtitrated, no endpoint. Overtitration process evidentaly was not done correctly. Footnote oxygen bad. 104 Oxygen is 0.02 high. No analytical problem noted, within WOCE specs. Oxygen is acceptable. Station 027 Cast 1 No comments on the Sample Log. Station 028 Cast 1 No comments on the Sample Log. 117 Delta-S at 1415db is -0.0064. Salinity also high compared with adjoining stations. No analytical problem noted. Gradient and "spike" feature in CTD trace. PI: "Salinity is acceptable." 115 Delta-S at 1720db is 0.0048. Salinity agrees with adjoining stations. Station 029 121 Oxygen appears low. Feature does not show in other data. No analytical problem noted. Footnote oxygen questionable. Also appears low vs. CTDO. 119 Sample Log: "Vent left open." Oxygen as well as other data are acceptable. 118 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 5 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. 109 Oxygen appears low. Feature shown in high nutrients. No analytical problem noted. Oxygen is acceptable. 101 Delta-S at 4035db is 0.0025. Salinity agrees with adjoining stations. 101-109 NO3 and PO4 appear high. Feature does not show in S, O2, or SiO3. Nutrient analyst: "F1s look high a bit compared to adjacent stations. Adjusted F1s to match adjacent stations." Station 030 Cast 1 No comments on the Sample Log. 123 Oxygen appears ~0.1 high. No analytical problem found. Oxygen agrees with CTDO. PI: "Oxygen is acceptable." Station 031 Cast 1 No comment on the Sample Log. 117 Oxygen low and nutrients (NO3, PO4 SiO3) high. 109 Delta-S at 1110db is -0.0076. No analytical problem noted. Station 032 Cast 1 No comments on the Sample Log. 108 Oxygen low, nutrients high. Salinity appears to be acceptable. Feature probably real. 107 Oxygen low, nutrients high. Salinity appears to be acceptable. Feature probably real. 102 Delta-S at 1261db is -0.0067. No analytical problem found. Salinity lower than adjoining stations. Other data are acceptable. Gradient area. PI: "Salinity is acceptable." 101 Delta-S at 1509db is 0.004. No analytical problem found. Salinity higher than adjoining stations. Other data are acceptable. Gradient area. PI: "Salinity is acceptable." Station 033 116 Sample Log: "Leak from bottom end cap when vent cracked." Oxygen as well as other data are acceptable. 101 Salinity was ~.01 high. Autosal diagnostics indicate 4 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 034 Cast 1 No comments on the Sample Log. Duplicate salts were drawn and analyzed by third salinity analyst. Bottle 8 had no water left in it, but the other salts agreed except 6 which was 0.001 high and 1 was .003 high. Station 035 Cast 1 No comments on the Sample Log. 106 PO4 is ~0.03 high. Nutrient analyst: "No analytical problem found, data is acceptable." Station 036 Cast 1 No comments on the Sample Log. 106 Oxygen appears low compared with adjoining stations. PI: "NO3, PO4, but not silicate show similar (high) feature, low CFC-11-12 also, likely real." Nutrient Analyst: "SiO3 higher on chart, no problem." Oxygen is acceptable. 102 Oxygen appears high compared with adjoining stations. No complimentary feature in nutrients. Oxygen agrees with CTDO. Oxygen is acceptable Station 037 Cast 1 No comments on the Sample Log. 122 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 5 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. Other data are acceptable. Salinity is acceptable. 115 Oxygen appears low, nutrients high. Data are acceptable. 111 Oxygen: "PC hung up, sample lost." Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 5 tries to get a good reading. The original reading gave better results. Salinity is acceptable. Other data are acceptable. 106 Oxygen appears high, nutrients low. Data are acceptable. 103 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 5 tries to get a good reading. The original reading gave better results. Salinity is acceptable. Other data are acceptable. 101 Delta-S at 1272db is 0.0133. Autosal diagnostics indicate 5 tries to get a good reading. First reading was higher than the next set of readings. Footnote salinity bad. Other data are acceptable. Station 038 Cast 1 No comments on the Sample Log. 118 Oxygen low, nutrients (NO3, PO4, SiO3) high; Salinity low as well. 110 Delta-S at 1054db is 0.008. Autosal diagnostics indicate 5 tries to get a good reading. Autosal operator did not write down the first reading. Gradient area. Salinity and other data are acceptable. 106 Autosal diagnostics indicate 3 tries to get a good reading. First reading is a little better, but still high. Gradient area. Salinity and other data are acceptable. Station 039 Cast 1 No comments on the Sample Log. 107 Oxygen low. No problems noted during analysis. Footnote oxygen bad. Flask 1509. 105 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 5 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. 104 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 5 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 040 Cast 1 No comments on the Sample Log. 120-121 Nutrients appear to be switched on NO3 vs. PO4 plot. N:P ratios are low. Salinity agrees with the CTD and it is unlikely that the bottle leaked, since the salinity is at the salinity max. Nutrient analyst can find no problem with the data. Oxygen for 120 appears low on the station profile, vs. pressure, but not so low, compared to previous stations, that it could be considered questionable. These are in the appropriate order, they were not switched. 104 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 4 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 041 124 Sample Log: "Closed partly out of water." No water for salinity sample. 111-112 Oxygen is low and nutrients are high. salinity is a little low compared to CTD, but acceptable for gradient area. Feature must be real. 105 Delta-S at 2073db is 0.0179. No analytical problem indicated. Other data are acceptable. Footnote salinity bad. 103 Salinity had a large difference as compared with the CTD. Autosal diagnostics indicate 4 tries to get a good reading. The first readings gave better results and are used in this salinity calculation. The salinity is still too high. Delta-S at 2481db is 0.0056. Footnote salinity bad. 102 Delta-S at 2632db is 0.0027. Autosal diagnostics indicate 3 tries to get a good reading. The first reading gave better results and are used in this salinity calculation, but still out of WOCE specs. Variation in the CTD trace. PI: "Salinity is acceptable." 101 Delta-S at 2824db is 0.0092. No analytical problem indicated. Other data are acceptable. Footnote salinity bad. Station 042 124 Sample Log: "Closed partly out of water." 112 Delta-S at 1060db is -0.0065. Autosal diagnostics do not indicate a problem with the analyses. Other samples are acceptable. Agrees fairly well with adjoining stations for this gradient. Salinity is acceptable. 106 Delta-S at 1714db is 0.0261. Autosal diagnostics indicate 7 tries to get a good reading, indicating a problem with the samples. Other samples are acceptable. Footnote salinity bad. 101 Delta-S at 2518db is 0.0026. The first readings gave better results and are used in this salinity calculation. Salinity is out of WOCE specs. Footnote salinity questionable. Station 043 Cast 1 No comments on the Sample Log. 110 Oxygen: "OT (No EP)." Delta-S at 1213db is 0.0072. Autosal diagnostics indicate 3 tries to get a good reading, indicating a problem with the samples. Salinity operator did not annotate the first reading. PI: "Doesn't look so far off on the plot, salinity is acceptable." 109 Large salinity difference. Suppression switch was set incorrectly. After correcting the data, the agreement is much better. Salinity is acceptable. Station 044 106 Sample Log: "Vent not tightly closed." Oxygen as well as other data are acceptable. Station 045 Cast 1 No comments on the Sample Log. 118 Oxygen is high on station profile, nutrients are low. Salinity agrees with CTD and adjoining stations. Data is acceptable. 115 Oxygen is high on station profile, nutrients are low. Salinity agrees with CTD and adjoining stations. Data is acceptable. 113 Salinity ran out of water before reading could be obtained during analysis. Footnote salinity lost. Other data are acceptable. 107 Delta-S at 1606db is 0.0065. No analytical problem found. Salinity is acceptable, feature also seen in CTD trace. 105 SiO3 high, Oxygen low. Data are acceptable. Station 046 Cast 1 No comments on the Sample Log. 103 Delta-S at 1662db is 0.0065. Autosal diagnostics indicate 5 tries to get a good reading, indicating a problem with the samples. The first readings gave better results and are used in this salinity calculation. Salinity still appears slightly high. Footnote salinity questionable. 101 Delta-S at 1831db is 0.0057. Autosal diagnostics indicate 5 tries to get a good reading, indicating a problem with the samples. The first readings gave better results and are used in this salinity calculation. Salinity still appears slightly high. Footnote salinity questionable. Station 047 Cast 1 No comments on the Sample Log. 114 The first readings gave better results and are used in this salinity calculation. Station 048 Cast 1 No comments on the Sample Log. 104 The first readings gave better results and are used in this salinity calculation. Oxygen appears low, nutrients appear high. Data is acceptable. PI: "Likely okay, matches CTD." Station 049 Cast 1 No comments on the Sample Log. 106-107 Oxygen flasks changed during sampling. Data recorded properly and is acceptable. Station 050 Cast 1 No comments on the Sample Log. 108 Low N:P, the NO3 and PO4 stations profiles looked good. Nutrient Analyst: "No analytical problem, gradient." Station 051 108 Sample Log: "Vent not closed." Oxygen as well as other data are acceptable. 105 Oxygen high, nutrients (NO3, SiO3,PO4) low. Data are acceptable. 103 The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 052 Cast 1 No comments from the Sample Log. 118 SiO3 low ~0.9. Nutrient analyst: "Looks the same as Sta 051, in mixed layer." 102-103 SiO3 0.4 low, within specs of the measurement. Nutrient analyst: "No problem noted." 101 PO4 0.05 high, O2 low. PO4 agrees with Station 055. Station 053 122 High on N:P plot. Nutrient analyst: "Gradient, data is acceptable." 108 Sample Log: "Vent is open." Oxygen as well as other data are acceptable. SiO3 is low. Nutrient analyst: "Probably bad, code questionable." 105 Delta-S at 1618db is -0.0035. No analytical problems noted. Salinity agrees with adjoining stations. Gradient area, salinity is acceptable. 103 O2 high. PI: "Doesn't fit in CTDO. Freon did not measure to assist in this. Doesn't match CTDO, but similar to Stas. 054 & 055. Oxygen is acceptable." 102 Oxygen: "PC lock-up, lost sample. Station 054 117 Oxygen: "PC locked up, sample lost." 114 Oxygen low, nutrients (NO3, PO4, SiO3) high. Data are acceptable. 108 Sample Log: "Leaking when valve opened." Oxygen and other data are acceptable. DeltaS at 1159db is 0.0064. No analytical problem noted. Feature in CTD trace produced by bottle stop. Gradient area. Salinity agrees with adjoining stations. Salinity is acceptable. 104 Delta-S at 1565db is 0.0029. No analytical problem noted. Gradient area. Salinity is acceptable. Station 055 Cast 1 No comments on the Sample Log. 110 O2 maybe high. PI: "No freon sample, oxygen appears to be okay compared with plots of several stations." 109 PI: "Oxygen low, maybe match the upcast CTD, probably similar to 056. Station 056 Cast 1 No comments on the Sample Log. 118 Oxygen is a little high, but nutrients are low. Salinity looks good on station profile. Nutrient Analyst: "Almost looks like sample 19 & 18 are reversed or reversal of trip." 114 Salinity appears high vs. CTD and adjoining stations. Gradient area. Salinity analyst had trouble getting readings to agree. First reading is better, but still high. Footnote salinity questionable. 108 O2 low. PI: "Or 109 O2 high? but both match upcast. Freon not sampled at all bottles. Oxygen is acceptable." Station 057 Cast 1 No comments on the Sample Log. 102 Delta-S at 1513db is 0.0027. No analytical problem noted. Gradient area. Feature in CTD trace produced by ship roll during sampling may cause the difference in salinity values. Salinity is acceptable. Station 058 Cast 1 No comments on the Sample Log. 111 Oxygen appears a little low, but nutrients appear a little high. Salinity agrees with the CTD and adjoining stations. Data are acceptable. 104 The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 059 Cast 1 Sample Log: "Battery died on O2 thermometer." 110 Oxygen appears a little high, but nutrients appear a little low. Salinity agrees with the CTD and adjoining stations. Data are acceptable. 104 Oxygen appears a little high, but nutrients appear a little low. Salinity agrees with the CTD and adjoining stations. Data are acceptable. 101 The first readings gave better results and are used in this salinity calculation. Station 060 Cast 1 No comments on the Sample Log. 106 N:P ratio low. Nutrient Analyst: "N:P gradient, data are acceptable." Station 061 Cast 1 No comments on the Sample Log. Station 062 Cast 1 No comments on the Sample Log. Station 063 Cast 1 No comments on the Sample Log. 102 Oxygen appears low but nutrients are high. Data are acceptable. Station 064 Cast 1 No comments on the Sample Log. 113-115 N:P high. NO3 and PO4 look okay on property plots and the N:P plot agrees with Station 068. Station 065 Cast 1 No comments on the Sample Log. 102 Delta-S at 1011db is 0.006. No analytical problem noted. Salinity is not any higher than bottles 3-5 compared with 064 and 067. Does not appear high when plotted on CTD trace. Salinity is acceptable. Oxygen is high and nutrients are low except SiO3 which is also high. Oxygen also agrees with CTDO trace. Station 066 Cast 1 No comments on the Sample Log. 101-102 PO4 and SiO3 appear a little high. Oxygen is lower than Stations 065 and 067, but higher than Station 068. Data are acceptable. Station 067 Cast 1 No comments on the Sample Log. 101 Delta-S at 1518db is 0.0039. No analytical problem noted. CTD trace shows a mass of features which are created from the bottle trip. Salinity is acceptable. Station 068 Cast 1 No comments on the Sample Log. 115 Oxygen high and nutrients low, salinity agrees with CTD. Data are acceptable. 107 Delta-S at 1617db is 0.0029. No analytical problems noted. Gradient area. Salinity is acceptable. 104 Delta-S at 2072db is 0.0031. No analytical problems noted. Gradient area. Salinity is acceptable. Station 069 123 Sample Log: "Low on water for tritium; no water left for salts." 119-120 Console Ops: "20 tripped first then 19." This was done through the software, no levels were missed. 118 Console Ops: "No confirm, then confirm." 102 Delta-S at 2628db is 0.0025. The first readings gave better results and are used in this salinity calculation. Station 070 108 Sample Log: "Vent not quite closed." Oxygen as well as other data are acceptable. 102 Oxygen is low, nutrients are high. Salinity agrees with adjoining stations. Data are acceptable. Station 071 Cast 1 No comments on the Sample Log. Console Ops: "Down trace 30-75m, something stuck in conductivity cell?" 122 Oxygen high, nutrients low, salinity agrees with CTD. 103 Autosal diagnostics indicate 4 tries to get a good reading, indicating a problem with the samples. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 072 120 Delta-S at 3db is 0.0296. Autosal diagnostics do not indicate a problem. Salinity as well as other data are acceptable. 104 Delta-S at 1717db is -0.0026. Autosal diagnostics do not indicate a problem. Gradient area. Salinity is acceptable. 101 Sample Log: "Vent open." Oxygen as well as other data are acceptable. Station 073 Cast 1 No comments on the Sample Log. 115 No nutrients drawn, sampling error. 112 Delta-S at 567db is 0.0227. Autosal diagnostics do not indicate a problem. Salinity agrees with adjoining stations and CTD down trace. Oxygen is low and nutrients are high. Data are acceptable. Station 074 121 Sample Log: "Closed partially out of water." Oxygen as well as other data are acceptable compared to adjoining stations. 114 Low Oxygen, nutrients are a little high and overlay the adjoining stations, salinity is a little low compared to adjoining stations and CTD. Data are acceptable. 113 Delta-S is -0.0583. Salinity is low compared with adjoining stations and CTD down trace as well as up. Autosal diagnostics do not indicate a problem. Footnote salinity questionable. Other data are acceptable. Station 075 Cast 1 No comments on the Sample Log. 108 Nutrients low, O2 high, salinity agrees with CTD. Data are acceptable. Station 076 Cast 1 No comments on the Sample Log. 115 Oxygen low, corresponding high feature not in nutrients. Low oxygen shown in CTDO trace. 103 SiO3 appears low compared with following stations, it agrees with previous stations. Data are acceptable. Station 078 Cast 1 No comments on the Sample Log. Station 079 Cast 1 No comments on the Sample Log. 109 Oxygen: "Sample lost." No further explanation. Station 080 Cast 1 No comments on the Sample Log. 113 Oxygen high, feature is also in nutrientslow. CTDO also indicates high O2. Oxygen is acceptable. 106 Oxygen appears low, corresponding high feature not seen in nutrients. CTDO also indicates high O2. 101 Oxygen appears high, corresponding low feature not seen in nutrients. CTDO also indicates high O2. 101-104 NO3 and PO4 a little higher than previous stations, looks okay on N:P plot. Station 081 113 Oxygen appears high. Feature does not show in nutrients. Could possibly show in CTDO, but difficult to tell. Does agree with Sta. 083. 111 Salinity appears high, O2 low, but salinity and O2 agree with CTD. 108 Sample Log: "Vent leaking." Oxygen as well as other data are acceptable. 108-113 SiO3 slightly higher than adjoining stations, NO3 too. PO4 appears low. Nutrient Analyst: "PO4 okay, N:P's look normal. Station 082 Cast 1 No comments on the Sample Log. Station 083 128 Sample Log: "3 micro-rinses on salinity." Salinity is acceptable. 113-116 Problem with the run, it appears to have shifted according to the data, but the shift does not show in the peaks. SiO3 is questionable. Station 084 Cast 1 No comments on the Sample Log. 103 PO4 too high. Nutrient Analyst: "Higher on trace as well-doesn't look right-maybe contaminated? PO4 is questionable." PI: "Code PO4 bad." 101-125 Unrecoverable fitting problems for CTDO (<400M, apparent offset @ 450M down cast. Footnote CTDO lost. Station 085 Cast 1 No comments on the Sample Log. 117 Duplicate O2 drawn. SiO3 1.0 low. Nutrient Analyst: "Okay on chart, peak okay. Agrees with Station 084 as well. Gradient area. SiO3 is acceptable." 101 Delta-S at 2959db is 0.0078. Bottle salinity is acceptable. Large spikes in CTD data. 101-125 Unrecoverable fitting problems for CTDO (<200M, apparent offset @ 200M down cast. Footnote CTDO lost. Station 086 Cast 1 No comments on the Sample Log. 119 Triplicate O2 drawn. 104 Delta-S at 2751db is 0.0025. PI: "Noisy CTD profile, so okay." Footnote CTD salinity questionable. 103 Delta-S at 2821db is 0.0057. PI: "Noisy CTD profile, so okay." Footnote CTD salinity questionable. 102 Delta-S at 2862db is 0.0044. PI: "Noisy CTD profile, so okay." Footnote CTD salinity questionable. 101 Delta-S at 2908db is -0.0073. PI: "Noisy CTD profile, so okay." Footnote CTD salinity questionable. 101-127 Unrecoverable fitting problems for CTDO (<100M, apparent offset @ 100M down cast. Footnote CTDO lost. Station 087 Cast 1 No comments on the Sample Log. 103 Delta-S at 2702db is 0.0037. PI: "Noisy CTD profile, bottle salinity okay." Footnote CTD salinity questionable. No CTDO is calculated because the CTD Salinity is coded questionable. 102 Delta-S at 2754db is -0.003. PI: "Noisy CTD profile, bottle salinity okay." Footnote CTD salinity questionable. No CTDO is calculated because the CTD Salinity is coded questionable. Station 088 Cast 1 No comments on the Sample Log. 116 Salinity is higher than CTD profile. Autosal diagnostics do not indicate a problem. Salinity appears higher than adjoining stations, but not too much more than other salinity values in this gradient. It looks like it could be a drawing error. Footnote salinity questionable. 114 Salinity is higher than CTD profile. Autosal diagnostics do not indicate a problem. Salinity appears higher than adjoining stations, but not too much more than other salinity values in this gradient. It looks like it could be a drawing error. Footnote salinity questionable. 109 Delta-S at 1967db is 0.0066. Autosal diagnostics do not indicate a problem. Gradient. Salinity is acceptable. PI: "Code salinity as questionable." 108 Delta-S at 2068db is 0.0025. Autosal diagnostics do not indicate a problem. Gradient. Salinity is acceptable. Station 089 127 Sample Log: "Running out of water." Salinity is acceptable. 119 Oxygen: "Sample is lost, thio tube was bent and not dispensing properly. Footnote oxygen lost. 109 Delta-S at 1639db is 0.003. Autosal diagnostics do not indicate a problem. Gradient area. Salinity is acceptable. Station 090 Cast 1 No comments on the Sample Log. 105 The first readings gave better results and are used in this salinity calculation. 102 Delta-S at 1745db is 0.0059. Autosal diagnostics do not indicate a problem. There is a "spike" in the CTD trace which is probably giving the large difference. This is real data at a bottle stop and is showing the difference in just a few seconds of sampling. Salinity is acceptable. 101-123 Unrecoverable fitting problems for CTDO (<100M, apparent offset @ 100M down cast. Footnote CTDO lost. Station 091 Cast 1 No comments on the Sample Log. Station 092 Cast 1 No comments on the Sample Log. Station 093 Cast 1 No comments on the Sample Log. Station 094 Cast 1 No comments on Sample Log. STD dial 5 units higher than previous and next runs. This would only be a difference if 0.001 PSU and is negligible on this shallow station. 110 Delta-S at 4db is 0.0455. CTD trace has a large "spike" in it. Footnote CTD salinity questionable. No CTDO is calculated because the CTD Salinity is coded bad. 109 Delta-S at 32db is 0.0431. CTD trace has a large "spike" in it. Footnote CTD salinity questionable. No CTDO is calculated because the CTD Salinity is coded bad. Station 095 Cast 1 No comments on the Sample Log. 111 Delta-S at 3db is 0.0375. Autosal diagnostics do not indicate a problem. Lots of variation in CTD trace at the time of bottle trip. Footnote CTD salinity questionable, just not good for bottle trip. No CTDO is calculated because the CTD Salinity is coded bad. 109 Delta-S at 103db is -0.044. Autosal diagnostics do not indicate a problem. Footnote CTD salinity questionable, just not good for bottle trip. No CTDO is calculated because the CTD Salinity is coded bad. Station 096 114 Delta-S at 4db is -0.0297. Autosal diagnostics do not indicate a problem. 113 The first readings gave better results and are used in this salinity calculation, but made a 0.005 difference. 108 Sample Log: "Leaking when vent opened." Oxygen as well as other data are acceptable. 102 Triplicate O2 drawn. Station 097 Cast 1 No comments on the Sample Log. 110 Delta-S at 2db is 0.0409. Autosal diagnostics do not indicate a problem. Salinity is acceptable. 109 Delta-S at 44db is 0.049. Autosal diagnostics indicate 3 tries to get a good reading. Used the first reading The first readings gave better results and are used in this salinity calculation. Salinity is a little lower than adjoining stations. Salinity is acceptable. 108-109 N:P low. Nutrient Analyst: "NO3 and PO4 are acceptable." Station 098 Cast 1 No comments on the Sample Log. Station 099 Cast 1 No comments on the Sample Log. Station 100 Cast 1 No comments on the Sample Log. 103 Delta-S at 1042db is -0.0167. No analytical problem. Large spike in CTD data. Station 101 117 Oxygen appears low, however, it is higher than 100 and lower than 102. Lower nutrients show that the feature is real. 108 Sample Log: "Vent loose." Oxygen as well as other data are acceptable. Station 102 106 PO4 low, NO3 low vs other stations, but SiO3 is not. Nutrient analyst: "Yes, SiO3 is lower, just not as pronounced. No analytical problem." 105 Sample Log: "oxygen redrawn." Oxygen as well as other data are acceptable. Delta-S at 1809db is 0.0028. Salinity is a little high Lots of variation seen in CTD profile. No analytical problem noted. PI: "Salinity is acceptable." 103 Delta-S at 2038db is -0.0051. Gradient area. No analytical problem noted. lots of variation seen in CTD profile at bottle trip. Salinity is acceptable. Station 103 128 Sample Log: "No water for surface salts." Station 104 129 O2 appears high compared to adjoining stations, PO4 and NO3 are lower. Data are acceptable. 114 Delta-S at 1570db is 0.0052. Autosal diagnostics do not indicate a problem. Salinity minimum, data is acceptable. 110 Delta-S at 2378db is 0.0027. Autosal diagnostics do not indicate a problem. Salinity maximum, salinity is acceptable. 109 Delta-S at 2530db is 0.0032. Autosal diagnostics do not indicate a problem. Salinity maximum, salinity is acceptable. 108 Delta-S at 2631db is 0.0037. Autosal diagnostics do not indicate a problem. Lots of features in the salinity profile. Data are acceptable. 106 Delta-S at 2774db is -0.0052. Autosal diagnostics do not indicate a problem. Lots of features in the salinity profile. Data are acceptable. 104 Triplicate O2 drawn. 103 Delta-S at 2957db is -0.0035. Autosal diagnostics do not indicate a problem. Lots of features in the salinity profile. Data are acceptable. 102 Triplicate O2 drawn. Station 105 Cast 1 No comments on the Sample Log. 129 Oxygen: "OT (No EP)." Oxygen as well as other data are acceptable. 126 O2 low, high feature also seen in nutrients. Data are acceptable. 122 Salinity high compared to the CTD. The first readings gave better results and are used in this salinity calculation. The salinity is acceptable after the correction. O2 high, feature is also seen in lower nutrients. Data are acceptable. 115 Delta-S at 1468db is 0.0086. Autosal diagnostics do not indicate a problem. Salinity appears high. Other data are acceptable. Footnote salinity questionable. PI: "Code salinity bad." 111-125 NO3 low. Nutrient Analyst: "Reanalyzed data and made a correction to NO3. Data are now acceptable." 107 Delta-S at 2786db is 0.0044. Autosal diagnostics do not indicate a problem. Lots of variation in CTD profile at bottle trip. Salinity as well as other data are acceptable. 105 Delta-S at 3010db is -0.0028. Autosal diagnostics do not indicate a problem. Lots of variation in CTD profile at bottle trip. Salinity as well as other data are acceptable. 104 Delta-S at 3070db is -0.0029. Autosal diagnostics do not indicate a problem. Lots of variation in CTD profile at bottle trip. Salinity as well as other data are acceptable. 103 Delta-S at 3132db is -0.0028. Autosal diagnostics do not indicate a problem. Lots of variation in CTD profile at bottle trip. Salinity as well as other data are acceptable. 102 Delta-S at 3194db is -0.0043. Autosal diagnostics do not indicate a problem. Lots of variation in CTD profile at bottle trip. Salinity as well as other data are acceptable. Station 106 Cast 1 No comments on the Sample Log. Station 107 108 Sample Log: "Vent open." Vent is not as tight as the others. Oxygen as well as other data are acceptable. Station 108 Cast 1 No comments on the Sample Log. 128 Delta-S at 35db is -0.046. Autosal diagnostics do not indicate a problem. CTD profile indicates a lot of mixing "spikes". Salinity is acceptable. 122 Triplicate O2 drawn. 111 Delta-S at 2119db is 0.0027. Autosal diagnostics do not indicate a problem. Gradient area. Salinity is acceptable. 110 Triplicate O2 drawn. Station 109 Cast 1 No comments on the Sample Log. 130 Nutrients not analyzed, no reason noted, suspect drawing problem. Footnote nutrients lost. 129 Oxygen: "Sample lost, PC Hung up during titration." 123 Oxygen: "Sample lost, PC glitch." 109 Delta-S at 2499db is 0.0027. Autosal diagnostics do not indicate a problem. Salinity agrees with adjoining stations. 108 Salinity appears high compared with CTD. Autosal diagnostics do not indicate a problem. Salinity agrees with adjoining stations. 101 NO3 low. Nutrient Analyst: "Corrected data. NO3 is acceptable." Station 110 Cast 1 No comments on the Sample Log. 119 Oxygen: "Overtitrate." Oxygen as well as other data are acceptable. 107 Delta-S at 2470db is -0.0049. Gradient area. Salinity is acceptable. 106 Salinity disagreed with CTD data. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. 104 Oxygen: "Overtitrate." Oxygen as well as other data are acceptable. 103 Salinity disagreed with CTD data. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. 102 Delta-S at 3145db is -0.0041. CTD indicates a lower salinity at this level. Salinity is acceptable. Station 111 Cast 1 No comments on the Sample Log. 119 Oxygen appears high, CTDO indicates higher oxygen is acceptable. PO4, SiO3 and NO3 low verifying this as a real feature. Station 112 Cast 1 No comments on the Sample Log. 119 Nutrients appear low, oxygen high. Salinity is acceptable. This feature is real. 115 Salinity appears high compared with CTD. CTD indicates a lot of mixing. Salinity is acceptable. Station 113 Cast 1 No comments on the Sample Log. 109 Salinity: "Lip was cracked on the bottle." Replaced the bottle. Salinity is acceptable. Station 114 125 Sample Log: "Ran out of water; no tritium, no salinity." 117 Oxygen high, nutrients low. Data are acceptable. 114 Delta-S at 689db is -0.0090. Autosal diagnostics do not indicate a problem. PI: "High gradient." Data are acceptable. Station 115 Cast 1 No comments on the Sample Log. Station 116 Cast 1 No comments on the Sample Log. 104 Delta-S at 2529db is -0.0025. Autosal diagnostics do not indicate a problem. Large difference between down and up trace. Also a large difference at this bottle trip. Salinity is acceptable. 101 Salinity appears a little high compared with adjoining stations and CTD. Footnote salinity questionable. Station 117 Cast 1 No comments on the Sample Log. 113-114 SiO3 low, and so is NO3. Data are acceptable. 109 Triplicate O2 drawn. 102 Triplicate O2 drawn. Station 118 Cast 1 No comments on the Sample Log. 101-102 Low SiO3, NO3 and PO4 also show this low feature and O2 a little higher than adjoining stations. Station 119 Cast 1 No comments on the Sample Log. 119 Low NO3 and PO4, but SiO3 does not show this low feature. Nutrient Analyst: "No analytical problems. NO3 and PO4 are within WOCE specs. Data are acceptable." 111 Delta-S at 2426db is -0.0025. Autosal diagnostics do not indicate a problem. Higher salinity value also seen in CTD down/up trace within a salinity minimum area. Salinity is acceptable. 101 Salinity a little high. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Oxygen also appears slightly low, but nutrients are slightly compared with Station 118. Data are acceptable. Station 120 Cast 1 No comments on the Sample Log. 128 Triplicate O2 drawn. 126 Low nutrients, O2 slightly high. Data are acceptable. Station 121 Cast 1 No comments on the Sample Log. 124 Nuts appear high. CO2 reports bottle problem. O2 low but CTDO confirms O2 is acceptable. Salinity agrees with CTD. Data are acceptable. 101-103 SiO3 appears low. PO4 is a little lower than adjoining stations. Nutrient Analyst: "No analytical problem found. Salinity also appears to be a little lower on the station profile." Data are acceptable. Station 122 130-131 Sample Log: "Closed just below the surface to avoid contamination from deck washing." There are no samples taken here. 124 Triplicate O2 drawn. 123 O2 low, nutrients high, salinity agrees with CTD. Data are acceptable. 118 Triplicate O2 drawn. 114 Delta-S at 1312db is 0.0061. Autosal diagnostics do not indicate a problem. Does not agree with down or up CTD trace. Does not agree with adjoining stations, but there was not sampling at this pressure. Footnote salinity questionable. 102 Delta-S at 3539db is -0.0025. Autosal diagnostics do not indicate a problem. There is also a difference between the down and up CTD trace indicated a lot of variations in the water being sampled. Salinity is acceptable. 101 Delta-S at 3639db is -0.0029. Autosal diagnostics do not indicate a problem. There is also a difference between the down and up CTD trace indicated a lot of variations in the water being sampled. Salinity is acceptable. Station 123 Cast 1 No comments on the Sample Log. 113 Oxygen high compared with adjoining stations. Nutrients are low. Data are acceptable. 103 Salinity high compared to CTD. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. 101 Delta-S at 4313db is -0.0025. Autosal diagnostics do not indicate a problem. Salinity is lower than both the down and up CTD trace. It also appears low on the station profile. The adjoining stations are not as deep as this station. This is just slightly out of WOCE specs. Footnote salinity questionable. Station 124 Cast 1 No comments on the Sample Log. 109-110 Nutrients low, oxygen high. Salinity agrees with CTD. Data are acceptable. Station 125 124 Oxygen low, nutrients high. Salinity agrees with CTD. Data are acceptable. 123 Oxygen high, nutrients low. Salinity agrees with CTD. Data are acceptable. 121 Oxygen high, nutrients low. Salinity agrees with CTD. Data are acceptable. 109 Oxygen: "Overtitrated, no end point." Oxygen is acceptable. 105 Sample Log: "Oxygen had to be redrawn, bubbles after stoppering." Oxygen is acceptable. Station 126 Cast 1 No comments on the Sample Log. 130 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 127 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 126 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 120 Delta-S at 630db is 0.01. Autosal diagnostics do not indicate a problem. Salinity minimum, large variation in CTD trace at bottle trip. Salinity is acceptable. Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 113 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 108 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 106 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. Station 127 119 Sample Log: "Had to redraw O2." O2 agrees with CTDO. Oxygen is acceptable. 115 Delta-S at 1406db is 0.008. Autosal diagnostics do not indicate a problem. Salinity agrees with CTD down trace; slight gradient. Salinity is acceptable. 109 Delta-S at 2704db is 0.0051. Autosal diagnostics indicate 3 tries to get a good reading, indicating a problem with the samples. But none of the other readings make the salinity lower. Gradient area. Salinity is acceptable. 108 Delta-S at 2957db is 0.0025. Autosal diagnostics do not indicate a problem. 103 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 102 Oxygen: "Overtitrate (No Endpoint)." Oxygen is acceptable. 101-104 SiO3 appears low compared to adjoining stations, doesn't show in PO4 or NO3, but O2 and salinity are higher than adjoining stations. Adjoining stations are not as deep as this station. Nutrient Analyst: "No analytical problems. Does agree with Station 126, also compares vs. oxygen. Data are acceptable." Station 128 Cast 1 No comments on the Sample Log. 110 Delta-S at 1718db is 0.0029. salinity does appear slightly high compared with CTD. However, it does appear to agree with Station 127. Gradient area. Salinity is acceptable. 106 Triplicate O2 drawn. Oxygen: "Overtitrate (No Endpoint), this was on one of the duplicate samples." Original oxygen agree with CTDO and appears okay on station profile. Station 129 Cast 1 No comments on the Sample Log. 128 Oxygen: "bad end point." O2 does appear slightly high. Footnote O2 questionable. 127 Oxygen: "bad end point." O2 appears to be acceptable, agrees with CTDO and station profile. 122 Oxygen: "Overtitrated (No EP)." O2 appears a little low, but in gradient area. Oxygen is acceptable. 120 Oxygen: "Overtitrated (No EP)." O2 appears a little high, but in gradient area. Oxygen is acceptable. Delta-S at 660db is -0.0124. Variation in CTD trace. Salinity is acceptable. 119 Oxygen: "Overtitrated (No EP)." O2 appears okay on station profile and agrees with CTDO, in gradient area. Oxygen is acceptable. 116 Delta-S at 1164db is 0.0327. Autosal diagnostics indicate 3 tries to get a good reading, indicating a problem with the samples. However, they were all fairly close and does not account for this large of a difference. It appears to be a drawing error. 114 Oxygen: "Overtitrated (No EP)." O2 appears okay on station profile and agrees with CTDO. Oxygen is acceptable. Station 130 Cast 1 No comments on the Sample Log. 119 Oxygen: "Overtitrated (No EP)." Oxygen as well as other data are acceptable. 116 Oxygen: "Overtitrated (No EP)." Oxygen as well as other data are acceptable. Station 131 Cast 1 No comments on the Sample Log. 128 Delta-S at 31db is -0.0293. Autosal diagnostics do not indicate a problem. Variation in CTD trace. Salinity as well as other data are acceptable. 126 Large difference with CTD. Autosal diagnostics do not indicate a problem. Variation in CTD trace. Salinity as well as other data are acceptable. 122 Large difference with CTD. Autosal diagnostics do not indicate a problem. Variation in CTD trace. Salinity as well as other data are acceptable. Station 132 Cast 1 No comments on the Sample Log. 102 Triplicate O2 drawn. 101-107 SiO3 may be high. Compared with adjoining stations and Station 034 and 031, it appears to be acceptable. Station 133 Cast 1 No comments on the Sample Log. 121 Oxygen appears high, nutrients low. O2 agrees with CTDO. Station 134 Cast 1 No comments on the Sample Log. 122 Oxygen: "Overtitration (No EP)." There is a feature in the CTD trace, which shows the oxygen low. Comparing to adjoining stations it may be a little high. Oxygen is acceptable. 115 Oxygen high, does not fit station profile or CTDO. Other data are acceptable. Footnote O2 bad. 110 Delta-S at 1612db is 0.0063. Autosal diagnostics do not indicate a problem. Gradient area. Salinity is acceptable. 108 Delta-S at 1912db is 0.0043. Autosal diagnostics do not indicate a problem. Variation in the CTD at the bottle trip and between the down and up. Station 135 Cast 1 No comments on the Sample Log. 120 Delta-S at 185db is 0.0262. Autosal diagnostics do not indicate a problem. Variation in CTD trace looking like a "spike", at the bottle trip. Salinity is acceptable. 118 Large difference between salinity and CTD. Autosal diagnostics do not indicate a problem. Variation in CTD trace looking like a "spike", at the bottle trip. Salinity is acceptable. 116 Delta-S at 558db is 0.0129. Autosal diagnostics do not indicate a problem. Variation in CTD trace looking like a "spike", at the bottle trip. Salinity is acceptable. Station 136 Cast 1 No comments on the Sample Log. 123 Large difference with CTD salinity. Autosal diagnostics do not indicate a problem. Variation in CTD at bottle trip showing as a "spike". 119 Large difference with CTD salinity. Autosal diagnostics do not indicate a problem. Compared with down and up salinity is acceptable. 116 Delta-S at 567db is -0.0199. Autosal diagnostics do not indicate a problem. Gradient area. Salinity is acceptable. 114 Delta-S at 739db is 0.0105. Autosal diagnostics do not indicate a problem. Variation in CTD at bottle trip showing as a "spike". Station 137 Cast 1 No comments on the Sample Log. 117 Nutrients low and oxygen high. Data are acceptable. Station 138 Cast 1 No comments on the Sample Log. 115 Delta-S at 607db is -0.0158. Autosal diagnostics do not indicate a problem. Gradient area, also a variation in the CTD trace resulting in a "spike" at the bottle trip. Salinity is acceptable. 103 Triplicate O2 drawn. 101 Oxygen is a little low on the station profile. Nutrients do not confirm this as a real feature. But it is difficult to explain a low oxygen. CTDO confirms the lower oxygen "tail". Station 139 Cast 1 No comments on the Sample Log. Station 140 Cast 1 No comments on the Sample Log. 109 Delta-S at 656db is -0.014. No analytical problem noted. Gradient area, feature in the CTD trace. Data are acceptable. Station 141 Cast 1 No comments on the Sample Log. 115 CTD profile shows variation in the water which may cause a difference between the salinity and the CTD. Salinity is acceptable. Station 142 Cast 1 No comments on the Sample Log. 121 Delta-S at 30db is -0.0279. Autosal diagnostics do not indicate a problem. Variations in CTD profile indicating an explanation for a large difference with the salinity. Salinity is acceptable. 120 Duplicate O2 drawn. Delta-S at 49db is -0.0255. Autosal diagnostics do not indicate a problem. Variations in CTD profile indicating an explanation for a large difference with the salinity. Salinity is acceptable. 115 Nutrients low and oxygen high. Data are acceptable. 108 Delta-S at 1050db is 0.01. Autosal diagnostics do not indicate a problem. CTD profile indicates a "spike" at the bottle trip. Salinity is acceptable. Station 143 Cast 1 No comments on the Sample Log. 114 Oxygen is high and nutrients are low. Data are acceptable. Station 144 Cast 1 No comments on the Sample Log. 110 Delta-S at 1058db is -0.0073. Autosal diagnostics do not indicate a problem. Difference between down and up CTD profile. Salinity is acceptable. 105 Delta-S at 1815db is -0.0027. Autosal diagnostics do not indicate a problem. Gradient area. Salinity is acceptable. Station 145 Cast 1 No comments on the Sample Log. 105 Triplicate O2 drawn. 102 Triplicate O2 drawn. 101 Delta-S at 2689db is 0.0029. Autosal diagnostics do not indicate a problem. Difference between the down and up CTD trace. Salinity is acceptable. Station 146 Cast 1 No comments on the Sample Log. 109 Delta-S at 1767db is 0.0031. Autosal diagnostics do not indicate a problem. Gradient area. Data are acceptable. 101 Oxygen: "Overtitrate, (No End Point)." Oxygen is acceptable. Difference with the CTD salinity. The first readings gave better results and are used in this salinity calculation. Salinity is acceptable. Station 147 Cast 1 No comments on the Sample Log. 116 Nutrients are high, oxygen is low. CTD agrees with salinity and oxygen. Feature is real. 110 Delta-S at 1056db is 0.009. Autosal diagnostics do not indicate a problem. Salinity agrees with adjoining stations. Salinity is acceptable. 106 Delta-S at 1713db is 0.0026. Autosal diagnostics do not indicate a problem. Salinity agrees with adjoining stations. Salinity is acceptable. 105 Oxygen: "Overtitrate (No End Point)." Oxygen is acceptable. 101 Delta-S at 2648db is 0.0054. Autosal diagnostics do not indicate a problem. Salinity agrees with adjoining stations. Variation in CTD trace as a "spike" at bottle trip. Salinity is acceptable. Station 148 Cast 1 No comments on the Sample Log. 112 Oxygen: "Overtitrate, (No End Point). Oxygen is acceptable. 104 Oxygen appears low. Gradient area, oxygen is acceptable. Station 149 Cast 1 No comments on the Sample Log. 115 Oxygen: "Overtitrate (No End Point)." Oxygen is acceptable. 110 Delta-S at 758db is 0.0178. Autosal diagnostics do not indicate a problem. Gradient in a maximum salinity feature as shown by the CTD. Salinity is acceptable. 103 Delta-S at 1921db is -0.0029. Autosal diagnostics do not indicate a problem. Feature in CTD up trace similar to a "spike" at bottle trip. Salinity is acceptable. Station 150 Cast 1 No comments on the Sample Log. 115 High O2. Feature does not show in nutrients. Salinity is acceptable. CTDO shows that oxygen is higher at this level. Oxygen is acceptable. 110 Delta-S at 668db is -0.0274. Gradient in a maximum salinity feature as shown by the CTD. Salinity is acceptable. 103 Delta-S at 1617db is 0.0031. Variation in CTD trace appearing as a "spike" at the bottle trip. Salinity is acceptable. 101 Delta-S at 1835db is 0.0027. Variation in CTD trace appearing as a "spike" at the bottle trip. Salinity is acceptable. 101-102 Nutrients high, O2 low. Feature is real. Station 151 Cast 1 No comments on the Sample Log. 102 Triplicate O2 drawn. Station 152 Cast 1 No comments on the Sample Log. 107 Nutrients high and oxygen and salinity low. Data are acceptable. 106 Oxygen: "Overtitrate, (No End Point)." Oxygen is acceptable. Station 153 Cast 1 Console Ops: "Special cast for LADCP bottom tracking test, minimal sampling." Only salinity drawn. 216 Sample Log: "Not enough water for salinity." 213 Oxygen: "Overtitrate, (No End Point)." Oxygen is acceptable. 211 O2 appears high on station profile, but CTDO also shows this high feature. Oxygen is acceptable. 101-103 No CTDO as planned. * Figures not included.