May 2001 1 May Nutation damping operations. CLC Narrow DB used. Maximum nutation 0.24 deg. half-cone. KEP GAS CR#621: FSS, UV (part 1) - 121.08:00 SCET. 2 May Nutation damping operations. Extended McElrath Man. initiated at 122.11:30 SCET. Nutation went from 0.44 to 0.34 deg. McElrath Man. initiated at 122.16:36 SCET. Nutation went from 0.39 to 0.13 deg. Maximum nutation 0.44 deg. half-cone. BAM-E calibration - 122.19:17 SCET. BAM-I calibration - 122.19:40 SCET. 3 May Nutation damping operations. Maximum nutation 0.25 deg. half-cone. GRU Routine Noise Test - 123.01:00 SCET. KEP GAS CR#622: FSS, UV (part 2) - 123.08:00 SCET. 4 May Nutation damping operations. McElrath Man. initiated at 124.04:26 SCET. Nutation went from 0.32 to 0.11 deg. Maximum nutation 0.32 deg. half-cone. 5 May Nutation damping operations. McElrath Man. initiated at 125.20:35 SCET. Nutation went from 0.35 to 0.08 deg. Maximum nutation 0.35 deg. half-cone. KEP GAS CR#623: FSS, UV (part 3) - 125.08:00 SCET. DSS-54 Receivers out of lock at 2-way acquisition. 125.05:29-05:40 11m realtime 1024 bps data lost. DR L05233 refers. 6 May Nutation damping operations. Maximum nutation 0.27 deg. half-cone. 7 May Nutation damping operations. McElrath Man. #1 initiated at 127.02:43 SCET. Nutation went from 0.19 to 0.12 deg. McElrath Man. #2 initiated at 127.12:43 SCET. Nutation went from 0.29 to 0.17 deg. McElrath Man. #3 initiated at 127.15:46 SCET. Nutation went from 0.21 to 0.10 deg. Maximum nutation 0.33 deg. half-cone. KEP GAS CR#624: FSS, UV (part 4) - 127.08:00 SCET. KEP IFC - 127.18:21 SCET. DSS-63 400kW transmitter warming caused 20kW transmitter drive off. 127.14:42-14:51 9m realtime 1024 bps data lost. DR L05240 refers. 8 May Nutation damping operations. McElrath Man. #1 initiated at 128.01:50 SCET. Nutation went from 0.37 to 0.10 deg. McElrath Man. #2 initiated at 128.10:42 SCET. Nutation went from 0.17 to 0.07 deg. Maximum nutation 0.37 deg. half-cone. 9 May Nutation damping operations. McElrath Man. #1 initiated at 129.00:31 SCET. Nutation went from 0.48 to 0.23 deg. McElrath Man. #2 initiated at 129.02:59 SCET. Nutation went from 0.34 to 0.11 deg. McElrath Man. #3 (extended) initiated at 129.23:04 SCET. Nutation went from 0.53 to 0.16 deg. Maximum nutation 0.53 deg. half-cone. KEP GAS CR#625: FSS, UV (part 5) - 129.08:00 SCET. DSS-34 lock drop due to wrong acquision template at transfer. 129.18:29-18:36 5m realtime 1024 bps data lost. DR L05381 refers. 10 May Nutation damping operations. McElrath Man. #1 (extended) initiated at 130.15:08 SCET. Nutation went from 0.37 to 0.05 deg. McElrath Man. #2 initiated at 130.22:29 SCET. Nutation went from 0.36 to 0.17 deg. Maximum nutation 0.37 deg. half-cone. HED Calibration - 130.01:00 SCET. KEP GAS CR#626: NG - 130.14:00 SCET. DSS-43 Accumulator pump failure resulted in antenna halt. 130.20:04-20:14 10m realtime 1024 bps data lost. DR A05389 refers. 130.20:36-20:45 9m realtime 1024 bps data lost due to additional re-sweep. 11 May Nutation damping operations. McElrath Man. #1 initiated at 131.03:00 SCET. Nutation went from 0.23 to 0.13 deg. An adjustment to DSS-63 output power from 0.7 to 1.0 kW during the track caused a nutation increase of about 0.18 to 0.35 deg at 131.09:00. DR L05256 refers. McElrath Man. #2 (extended) initiated at 131.10:22 SCET. Nutation went from 0.56 to 0.15 deg. McElrath Man. #3 (extended) initiated at 131.14:50 SCET. Nutation went from 0.53 to 0.17 deg. Maximum nutation 0.56 deg. half-cone. 12 May Nutation damping operations. McElrath Man. #1 initiated at 132.05:51 SCET. Nutation went from 0.40 to 0.12 deg. McElrath Man. #2 initiated at 132.11:24 SCET. Nutation went from 0.34 to 0.09 deg. McElrath Man. #3 with CLC enabled initiated at 132.20:11 SCET. Nutation went from 0.24 to 0.16 deg. Maximum nutation 0.40 deg. half-cone. 13 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 133.19:44 SCET. Nutation went from 0.47 to 0.06 deg. Maximum nutation 0.47 deg. half-cone. 14 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 134.10:57 SCET. Nutation went from 0.35 to 0.10 deg. Maximum nutation 0.35 deg. half-cone. KEP IFC - 134.15:20 SCET. DSS-63 Complex-wide power glitch. All subsystems re-initialized. 134.06:40-07:27 47m realtime 1024 bps data lost. DR L05265 refers. 134.08:07-08:15 8m realtime 1024 bps data lost due to additional 1-way to 2-way. DSS-34 transmitter late at U/L tansfer. DR A05401. 134.18:18-18:31 13m realtime 1024 bps data lost due to additional 1-way to 2-way. 15 May Nutation damping operations. McElrath Man. #1 with CLC enabled initiated at 135.02:39 SCET. Nutation went from 0.31 to 0.14 deg. McElrath Man. #2 with CLC enabled initiated at 135.06:20 SCET. Nutation went from 0.34 to 0.09 deg. Maximum nutation 0.34 deg. half-cone. BAM-I Motor Position 3 - 135.15:20 SCET. 16 May Nutation damping operations. McElrath Man. #1 with CLC enabled initiated at 136.06:01 SCET. Nutation went from 0.24 to 0.07 deg. McElrath Man. #2 with CLC enabled initiated at 136.10:08 SCET. Nutation went from 0.24 to 0.04 deg. Maximum nutation 0.28 deg. half-cone. BAM-I Matrix 6 - 136.15:35 SCET. SIM HET Calibration - 136.05:00 SCET. 17 May Nutation damping operations. McElrath Man. #1 with CLC enabled initiated at 137.03:29 SCET. Nutation went from 0.30 to 0.05 deg. McElrath Man. #2 with CLC enabled initiated at 137.12:46 SCET. Nutation went from 0.26 to 0.06 deg. Maximum nutation 0.30 deg. half-cone. DSS-54 problem with RCP-1 to TCA channel. DR L05288 refers. 137.09:15-09:17 2m realtime 1024 bps data lost. 09:19-09:29 10m realtime 1024 bps data lost. 09:31-09:32 1m realtime 1024 bps data lost. GRU CR#635: HV & Threshold changes - 137.15:29 SCET. 18 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 138.03:34 SCET. Nutation went from 0.24 to 0.08 deg. Maximum nutation 0.24 deg. half-cone. DSS-24 SCP problem. DR G06994 refers. 138.15:55-15:59 4m realtime 1024 bps data lost. KEP GAS CR#627: NG Indirect- 138.03:00 SCET. 19 May Nutation damping operations. McElrath Man. #1 with CLC enabled initiated at 139.00:18 SCET. Nutation went from 0.27 to 0.06 deg. McElrath Man. #2 with CLC enabled initiated at 139.15:48 SCET. Nutation went from 0.23 to 0.10 deg. Maximum nutation 0.32 deg. half-cone. 20 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 140.20:17 SCET. Nutation went from 0.23 to 0.08 deg. Maximum nutation 0.28 deg. half-cone. KEP GAS CR#628: FSS NG Mode Pt. 1 - 140.08:00 SCET. 21 May Nutation damping operations. McElrath Man. #1 with CLC enabled initiated at 141.16:31 SCET. Nutation went from 0.16 to 0.10 deg. McElrath Man. #2 with CLC enabled initiated at 141.20:56 SCET. Nutation went from 0.16 to 0.05 deg. Maximum nutation 0.34 deg. half-cone. DSS-24 LMC problems. DR L05297 refers. 141.04:07-04:22 18m realtime 1024 bps data lost. KEP IFC - 141.15:24 SCET. DSS-34 transmitter problem. DSS-43 filled in U/L gap from 141.18:55 to 20:30 ETT, when it transferred to DSS-34, once transmitter problem had been fixed. DR A05415 refers. 141.18:23-18:25 2m realtime 1024 bps data lost, due to transition to 1-way. 141.19:11-19:16 5m realtime 1024 bps data lost, due to transition to 2-way. 22 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 142.05:11 SCET. Nutation went from 0.23 to 0.08 deg. Maximum nutation 0.29 deg. half-cone. KEP GAS CR#629: FSS NG Mode Pt. 2 - 142.08:00 SCET. 23 May Nutation damping operations. Maximum nutation 0.25 deg. half-cone. HED Calibration - 143.01:00 SCET. 24 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 144.09:24 SCET. Nutation went from 0.21 to 0.05 deg. Maximum nutation 0.26 deg. half-cone. KEP GAS CR#630: FSS NG Mode Pt. 3 - 144.07:00 SCET. DSS-24 LBW opened to 35Hz caused drop in RX lock. 144.14:22-14:26 4m realtime 1024 bps data lost. DR G07019 refers. 25 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 145.05:36 SCET. Nutation went from 0.27 to 0.08 deg. Maximum nutation 0.27 deg. half-cone. 26 May Nutation damping operations. Maximum nutation 0.19 deg. half-cone. KEP GAS CR#631: FSS NG Mode Pt. 4 - 146.06:00 SCET. 27 May Nutation damping operations. Failed U/L TSF transfer (DSS-54 to DSS-24) instead of XA. 147.11:36-11:44 8m realtime 1024 bps data lost. DR G07029 refers. McElrath Man. with CLC enabled initiated at 147.13:30 SCET. Nutation went from 0.30 to 0.06 deg. Maximum nutation 0.30 deg. half-cone. 28 May Nutation damping operations. McElrath Man. with CLC enabled initiated at 148.20:48 SCET. Nutation went from 0.27 to 0.09 deg. Maximum nutation 0.27 deg. half-cone. KEP IFC - 148.15:34 SCET. KEP GAS CR#632: FSS NG Mode Pt. 5 - 148.05:00 SCET. 29 May Nutation damping operations. Maximum nutation 0.25 deg. half-cone. KEP GAS CR#637: NG - 149.12:00 SCET. 30 May Nutation damping operations. Maximum nutation 0.27 deg. half-cone. BAM-E calibration - 150.15:36 SCET. BAM-I calibration - 150.15:56 SCET. 31 May Nutation damping operations. Maximum nutation 0.32 deg. half-cone. McElrath Man. #1 with CLC enabled initiated at 151.06:06 SCET. Nutation went from 0.25 to 0.05 deg. 151.12:22-12:37 Command system problem caused switch from Idle2-Cal2 unexpectedly. AR106272. McElrath Man. #2 with CLC enabled initiated at 151.17:08 SCET. Nutation went from 0.32 to 0.12 deg. GRU Routine Noise Test (CR# 636) - 151.19:00 SCET.