August 2003
                                  
 1 August         HUS Heater tests - 213.17:25:27 to 213.17:29:43 SCET.
                  (HUS Heat OFF 64s, 3 x ON/OFF with 32s interval, heat ON.)

                  GRU CR #773: New program reload seq 1-6 - 213.17:26 SCET.

 213.21:15-21:29  13m realtime 4096bps plus 1h 22m playback 512bps data lost at 
(213.08:31-09:53) DSS14 due to antenna pointing problems.  Antenna conscan had been 
                  used earlier to try to improve signal.  DR N101249 refers.

 2 August         GRU reset command (anomaly ULY059 refers) - 214.01:08 SCET.

 214.15:08-15:26  10m realtime 512bps plus 8m realtime 1024bps data lost at DSS14 
                  due to problems with Antenna Pointing Assembly (APA) at AOS.  
                  DR G103116 refers.
 
 3 August         Earth pointing manoeuvre w/power save - 215.16.21 SCET.
  
 4 August         Routine operations

 5 August         Routine operations

 6 August         STO1 Calibration - 218.15:52 SCET.
                  Earth pointing manoeuvre w/power save - 218.13.41 SCET.

 7 August         HUS Heater tests - 219.15:24:59 to 219.15:35:07 SCET.
                  (HUS Heat OFF 64s, 8 x ON/OFF with 32s interval, heat ON.)   
                  SIM HET Calibration - 219.14:10 SCET.  (calibration performed at 
                  incorrect bitrate of 512bps, will repeat on DOY 222 at 1024bps)

 219.18:49-19:15  Intermittent bad data.  16m 1024bps real-time data lost due to 
                  RNS swap at DSS-24.  DR G103157 refers.

 8 August         Routine operations

 220.15:47-15:49  2m real-time 1024bps data loss and 12m 512bps data lost due to an 
(219.00:15-00:27) unexplained data hit during 4k playback.  No DR raised. 


 9 August         Earth pointing manoeuvre w/power save - 221.08:30 SCET.

10 August         GRU CR#772: Program reload, version 4 - 222.08:20 SCET.
                  SIM HET Calibration - 222.09:00 SCET.

11 August         GRU CR #773: New program reload seq 1-6 - 223.09:30 SCET.
                  GRU reset command (anomaly ULY059 refers) - 223.17:05 SCET. 

12 August         Earth pointing manoeuvre w/power save - 224.08:00 SCET.
                  GRU Program reload, version 3 (ULY059 refers) - 224.10:00 SCET.
                  GRU Program activation (ULY059 refers) - 224.17:20 SCET.                     

13 August         HED Calibration - 225.15:00 SCET.
                  GRU HV Level 0 - cancelled due to uplink failure at DSS-14.
 
 225.17:32-19:08  1h36m 1024bps real-time and 7h1m 512bps playback data lost due 
(225.07:11-14:12) to severe communication circuit failure at Goldstone.  Downlink 
                  restored at DSS-15. DR G103193 refers.

14 August         GRU HV Level 0 - cancelled due to uplink failure at DSS-24.

 226.17:39-17:51  12m 1024bps real-time data lost due to uplink failure at DSS-24.  
                  Feed mirrors not positioned/configured correctly. DR G103200 refers.

 226.21:41-22:05  Contingency command window opened at DSS-24 to send DSU commands 
                  for DOY 227.  Incorrect file transmitted, partial GRU load sent
                  before command aborted.    

15 August         Routine operations.

16 August         Earth pointing manoeuvre w/power save - 228.08.41 SCET.
                  GRU Program reload, version 3 (ULY059 refers) - 228.10:45 SCET.

 228.12:08-12:33  25m 1024bps real-time data lost due to long one-way accquisition
                  at DSS-63.  DR M101820 refers.

17 August         GRU Program activation (ULY059 refers) - 229.20:55 SCET. 

18 August         Routine operations.

 230.07:42-07:48  6m realtime 1024bps data lost due to long 1-way to 2-way acquisition
                  at DSS63.  No DR was raised.
  
19 August         Earth pointing manoeuvre w/power save - 231.14.56 SCET.
                  GRU HV Level 0 - 231.12:51 SCET.

 231.16:22-16:28  6m realtime 1024bps data lost due to long 1-way to 2-way acquisition
                  at DSS24.  No DR was raised.

                  Subreflector problems at DSS24 led to multiple data outages.  DR G103227
                  refers.  Outage summary as follows:
 231.17:04-17:22  18m realtime 1024 bps data lost.
 231.17:49-17:58  9m realtime 1024 bps data lost.
 231.18:14-18:25  84% realtime 1024 and 512bps data lost.

20 August         GRU Routine Noise Test - postponed until experiment configuration
                  completed.

                  HUS heater test, 96s OFF.
                   HUS Heat OFF - 232.17:09:09 SCET
                   HUS Heat ON  - 232.17:10:45 SCET

21 August         BAM-E calibration - 233.15:26 SCET.
                  BAM-I calibration - 233.15:36 SCET.
                  
22 August         GRU HV Level 1 - 234.17:22 SCET.
                  GRU HV Level 2 - 234.17:26 SCET.
                  GRU HV Level 3 - 234.17:32 SCET.
                  GRU HV Level 4 - 234.17:39 SCET.
 
23 August         Routine operations

24 August         Earth pointing manoeuvre w/power save - 236.08.56 SCET.

25 August         Routine operations

26 August         HED Calibration - 238.14:00 SCET.

 238.13:15-16:41  Intermittent data losses due to Receiver & Ranging Processor (RRP2)
                  failures at DSS-14.  RRP2 was reset.  DR G103264 refers.

27 August         Routine operations
                  
28 August         Earth pointing manoeuvre w/power save - 240.13.51 SCET.

 240.20:23-20:32  9m 1024bps real-time and 19m 512bps play-back data lost due to a 
(240.05:27-05:46) power outage at DSS-26. DR G103273 refers.

29 August         Routine operations

30 August         Routine operations

31 August         

 243.19:41-19:44  3m realtime 1024bps plus 29m playback 512bps data degraded by 63% due to