The following references were used in compiling the checklists, details, and installation notes and are not cited specifically in the text: 15. California Office of the State Architect and California Office of Emergency Services. 1990. Identification and Reduction of Nonstructural Earthquake Hazards in California Schools. Sacramento and Oakland: California OSA and OES. 16. Reitherman, Robert, and Steve Minor. 1989. Technical Guidelines for Earthquake Protection of Nonstructural Items in Communications Facilities. Oakland: California Office of Emergency Services Earthquake Program. 17. Wiss, Janney, Elstner Associates, Inc. 1994. Information on Protecting Your Home and Business from Nonstructural Earthquake Damage. Los Angeles: California Office of Emergency Services. 18. California Office of the State Architect. 1993. Earthquake Bracing of Water Heaters for Single-Family Homes. Sacramento: California OSA. 19. Reitherman, Robert. 1991. Nonstructural Earthquake Protection Manual for Idaho Schools. Boise: Idaho Bureau of Disaster Services. 20. Checklist of Nonstructural Earthquake Hazards. Sacramento: California Office of Emergency Services Earthquake Project. ANNOTATED BIBLIOGRAPHY This brief bibliography can direct those who require more detailed information to other bibliographies, such as those contained in the references below, and thus is not meant to be comprehensive. This bibliography includes, technical publications and nontechnical publications, both listed in alphabetical order, and also information on several organizations or government agencies with a specific focus on earthquake engineering issues. These organizations may be able to, help the reader identify more recent publications than those listed here. Technical Publications Applied Technology Council. 1992. ATC-29: Proceedings of Seminar and Workshop on Seismic Design and Performance of Equipment and Nonstructural Elements in Buildings and Industrial Structures. Redwood City, Calif.: ATC. * These proceedings contain papers with performance data, analytical methods, and/or suggested details for many specific items, including elevated tanks, ceilings, fire sprinklers, HYAC ducts and equipment, and computer access floors. Most of these papers also contain extensive reference lists pertinent to each specific topic. Ayres, J. M., T. Y. Sun, and F. R. Brown. 1973. "Nonstructural Damage to Buildings." In The Great Alaska Earthquake of 1964: Engineering. Washington D.C.: National Academy of Sciences. Ayres, J. M., and T. Y. Sun. 1973. 'Nonstructural Damage." In The San Fernando, California J Earthquake of February 9, 1971. Washington, D.C.: National Oceanic and Atmospheric Administration. * These were the first two comprehensive postearthquake damage analyses devoted to the topic of nonstructural components. The authors are mechanical engineers. Building Seismic Safety Council. 1992. NEHRP Recommended Provisions for the Development of Seismic Regulations for New Buildings. Part 1--Provisions (FEMA 222), Part 2-Commentary (FEMA 223). Washington, D.C.: FEMA., * The 1994 edition was in draft form at the time this document went to press. Building Seismic Safety Council. 1992. NEHRP Handbook for the Seismic Evaluation of Existing Buildings. (FEMA 178). Washington, D.C.: FEIMA. Building Seismic Safety Council. 1992. NEURP Handbook for the Seismic Rehabilitation of Existing Buildings. (FEMA 172). Washington, D.C.: FEMA. * Items 4, 5, and 6 are all part of a series of FEMA documents produced by the National Earthquake Hazards Reduction Program (NEHRP). These documents may be obtained without charge by writing to the address listed at the end of this bibliography. Dowrick, D. J. 1977. Earthquake Resistant Design: A Manual for Engineers and Architects. New York: John Wiley & Sons. * A comprehensive text, including two chapters on nonstructural issues: "Earthquake Resistance of Services," which concerns mechanical and electrical components, and "Architectural Detailing for Earthquake Resistance." The book has an international perspective with references to many different codes. Earthquake Engineering Research Institute. 1984. Nonstructural Issues of Seismic Design and Construction. Publication No. 84-04. Oakland, Calif.: EERI. * This is a technical overview based on a workshop sponsored by the National Science Foundation. It includes several technical papers and a discussion of key issues, and it lists many additional references. International Conference of Building Officials. 1994. Uniform Building Code, Volumes 1-3. Whittier, Calif.: ICBO. * See especially the "Earthquake Regulations." The UBC contains specific requirements for some items, such as steel storage racks. New editions of the UBC are issued every three years. The earthquake regulations are taken almost verbatim from the SEAOC "Blue Book," listed below, which also includes a useful commentary. McGavin, Gary L. 1981. Earthquake Protection of Essential Building Equipment: Design, Engineering, Installation. New York: John Wiley & Sons. * A book-length treatment of the subject. Especially appropriate for large, complex projects, such as hospitals or power plants. Office of the State Architect, Structural Safety Section. 1991. Interpretation of Regulations #IR 23-7, Title 24 California Administrative Code: Anchorage of Non-Structural Building Components and Hospital Equipment. Sacramento: California OSA. * The regulations legally pertain only to essential nonstructural items in California hospitals, but the regulations can provide a guide as to anchorage engineering of especially essential items for other types of buildings. The Office of the State Architect has been centrally involved in earthquake code regulations since the 1933 Long Beach earthquake. Schiff, Anshel J. 1980. Pictures of Earthquake Damage to Power Systems and Cost-Effective Methods to Reduce Seismic Failures of Electric Power Equipment. West Lafayette, Ind.: Purdue Research Foundation. * This is one of the few works in this subject area that is readable by the nontechnical audience. Engineering appendix and bibliography also included. Structural Engineers Association of California. 1990. Recommended Lateral Force Requirements and Commentary. San Francisco: SEAOC. * Also known as the SEAOC "Blue Book." The "Requirements" are adopted almost verbatim into the Uniform Building Code, while the "Commentary" explains the assumptions, limitations, and caveats that must be understood for the regulations to be used intelligently. The Structural Engineers Association of California has been active in the development of seismic code regulations, standards of practice, research, and testing for several decades. Structural Engineers Association of Northern California. 1993. Fall Seminar: Non-Structural Components--Design and Detailing. San Francisco: SEAONC. * These seminar notes include nine papers on the design and detailing of cladding, interior systems, and mechanical systems. Several of these papers also include extensive reference lists. U.S. Department of Defense. 1982. Seismic Design for Buildings. Tri-Service Manual TM 5-809-10. Washington, D.C.: Superintendent of Documents. * Commentary and calculation examples are provided; see especially Chapters 9, 10, and 11. Generally parallels the UBC but is written as a design aid rather than a code. U.S. Department of Defense. 1986. Seismic Design Guidelines for Essential Buildings. Tri- Service Manual TM 5-809-10-1. Washington, D.C.: Superintendent of Documents. * Chapters 6 and 7 cover nonstructural components and nonbuilding structures, respectively. Includes several design examples. (Revised edition by Wiss, Janney, Elstner Associates, Inc., due out in 1995). U.S. Department of Defense. 19:86. Seismic Design Guidelines for Upgrading Existing Buildings, Tri-Service Manual TM 5-809-10-2. Washington, D.C.: Superintendent of Documents. * Portions of Chapter 6, Chapter 9, and the design examples in Appendix 0 are related to nonstructural items. U.S. Department of Veterans Affairs, Office of Construction. 1976. Study to Establish Seismic Protection Provisions for Furniture, Equipment, and Supplies for VA Hospitals. Washington, D.C.: VA. 0 This guide shows typical nonstructural damage inside a hospital and illustrated restraint techniques with cost estimates for a variety of types of hospital equipment and furnishings; it includes a brief engineering appendix. Relevant for buildings other than hospitals, especially if laboratories are present. Yancey, C. W. C., and A. A. Camnacho. 1978. Seismic Design of Building Service Systems: The State of the Art. National Bureau of Standards Technical Note 970. Washington, D.C.: NBS. * A literature survey and review of present practice, especially with regard to the specific mandatory regulations of building codes. The National Bureau of Standards, a federal bureau, has been involved with earthquake research and postearthquake damage reports. Rihal, Satwant, Barry J. Goodno,, Hiroshi Ito, and Robert Reitherman. 1993. "Nonstructural Elements." In Design of Low-Rise Buildings Subjected to Lateral Forces, edited by Ajaya Kumar Gupta and Peter James Moss. Ann Arbor: CRC Press. * A chapter in a book intended for architects, engineers, building officials, and university professors. Most of this chapter concerns earthquakes rather than wind, and additional references are listed. Reitherman, Robert, and Steve Minor. 1989. Technical Guidelines for Earthquake Protection of Nonstructural Items in Communications Facilities. Oakland: California Office of Emergency Services Earthquake Program. * Intended for the facilities staffs who install and maintain telecommunications equipment. Includes simplified design guide for the selection of anchor bolts, drawings of anchorage and bracing details, and installation guidance. Technical Standards The following list of publications includes many of the specific design, fabrication, and/or installation requirements for particular nonstructural items. American Institute of Steel Construction (AISC). 1989. Manual of Steel Construction: Allowable Stress Design. Ninth Edition. American Petroleum Institute (API). 1988. Welded Steel Tanks for Oil Storage. API Standard 650. American Society of Mechanical Engineers (ASME). 1990. Safety Code of Elevators and Escalators. ASME A17. 1. American Society of Mechanical Engineers (ASME). Including addenda through 1993. Code for Pressure Piping. ASME B3 1. American Society of Mechanical Engineers (ASME). Including addendum through 1993. Boiler and Pressure Vessel Code. American Society For Testing and Materials (ASTM). 1991. Standard Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay- in Panel Ceilings. ASTM C635. American Society For Testing and Materials (ASTM). 1991. Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels. ASTM C636. American Water Works Association (AWWA). 1984. Welded Steel Tanks for Water Storage. D100. Ceilings and Interior Systems Construction Association (CISCA). 1991. Recommendations for Direct-Hung Acoustical Tile and Lay-In Panel Ceilings, Seismic Zones 0-2. Ceilings and Interior Systems Construction Association (CISCA). 1990. Recommendations for Direct-Hung Acoustical Tile and Lay-In Panel Ceilings, Seismic Zones 3-4. Institute of Electrical and Electronic Engineers (IEEE). 1975. Recommended Practice for Seismic Qualification of Class JE Equipment for Nuclear Power Generating Stations. IEEE Standard 344. Manufacturers Standardization Society of the Valve and Fitting Industry (MSS). 1988. Pipe Hangers and Supports : Materials, Design, and Manufacture. SP-58. National Fire Protection Association (NFPA). 1991. Standard for the Installation of Sprinkler Systems. NFPA-13. Rack Manufacturers Institute (RMI). 1990. Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks. Sheet Metal and Air Conditioning Contractors National Association (SMACNA). 1985. HVAC Duct Construction Standards, Metal and exible. Sheet Metal and Air Conditioning Contractors National Association (SMACNA). 1980. Rectangular Industrial Duct Construction Standards. Sheet Metal and Air Conditioning Contractors National Association (SMACNA), Sheet Metal Industry Fund of Los Angeles, and Plumbing Industry Council. 1992. Guidelines for Seismic Restraint of Mechanical Systems and Plumbing Piping Systems. Nontechnical References California Office of the State Architect and California Office of Emergency Services. 1990. Identification and Reduction of Nonstructural Earthquake Hazards in California Schools. Sacramento and Oakland: California OSA and California OES * Survey forms and drawings of bracing concepts for 27 nonstructural items. FBIS, Inc., and VSP Associates. 1987. Data Processing Facilities: Guidelines for Earthquake Hazard Mitigation. Sacramento, Calif.: VSP, Inc. * Intended for owners and operators of data processing facilities (DPF). Contains illustrative material on nonstructural hazards and upgrades for raised floors and mainframe computer systems, as well as components found in buildings in general. Not intended as a self- help guide, but provides DPF manager with a basis for discussing design criteria with an engineer. Noson, Linda, Todd Perbix, and Padraic Burke. 1989. Safer Schools: Earthquake Hazards, Nonstructural. Olympia, Wash.: Washington Superintendent of Public Instruction. Includes background information on earthquakes in Washington, survey checklists, and 32 pages of illustrations of nonstructural hazard reduction measures. Olshansky, Robert B. No date (c. 1992). Reducing Earthquake Hazards in the Central U.S.: Nonstructural Hazards. Memphis, Tenn.: Central United States Earthquake Consortium. * Prepared for the U.S. Geological Survey by the University of Illinois at Urbana-Champaign, Department of Urban and Regional Planning. Illustrations and explanations of nonstructural damage. Reid & Tarics Associates. 1982. Seismic Restraint Handbook for Furniture, Equipment, and Supplies. Washington, D.C.: Veterans Administration. * In addition to detailed administration procedures applicable to VA hospitals, the handbook contains detailed forms for collecting nonstructural survey data and producing cost estimates or lists of required materials and labor. Includes 18 pages of restraint details. Originally intended for use by engineering staffs at VA medical facilities, without the use of outside contractors or additional design/analysis assistance. Reitherman, Robert. 1989. Nonstructural Earthquake Hazard Mitigation for Hospitals and Other Health Care Facilities. FEMA Publication SM (Student Manual) 370. Washington, DC: FEMA. * Six chapters devoted to the nonstructural topic, some of them generally applicable and others more specific to hospitals. This is a manual used for a two-day course devoted to earthquake hazard reduction and emergency preparedness for hospital facilities. Organizations 1. Federal Emergency Management Agency (FEMA); California Office of Emergency Services (OES) Earthquake Program; Central United States Earthquake Consortium (CUSEC). A wide variety of publications, brochures, checklists, videotapes, and slide sets related to earthquake preparedness and nonstructural hazard mitigation are available from many state and federal agencies. Some of the items are tailored to meet differing needs in particular areas of the United States. Some are tailored for specific types of facilities, such as hospitals, schools, day care centers, nursing homes, or single-family residences. Many are available free of charge. FEMA has regional offices throughout the country, and most states have an office or department of emergency services that may have similar material. The list below includes only several key agencies. Federal Emergency Management Agency Mitigation Directorate 500 C Street. S.W. Washington, D.C. 20472 State of California Governor's Office of Emergency Services Earthquake Program 2800 Meadowview Road Sacramento, CA 95832 (Phone 916-262-1800; Fax 916-262-1840) Central United States Earthquake Consortium 2630 East Holmes Road Memphis, TN 38118 (Phone 901-345-0932; Fax 901-345-0998) 2. The National Center for Earthquake Engineering Research (NCEER) is associated with the State University of New York at Buffalo. Founded in 1987, NCEER sponsors academic research in earthquake engineering, publishes a quarterly bulletin, and has an extensive list of technical reports available by mail. NCEER also has a bibliographic database called QUAKELINE that covers the literature of earthquake engineering and natural hazards mitigation. The database contained over 24,000 records as of January 1994; approximately 400 additions are made each month. The database is accessible on Internet, through both academic computing services and commercial providers. National Center for Earthquake Engineering Research State University of New York at Buffalo Red Jacket Quadrangle, Box 610025 Buffalo, NY 14621-0025 (Phone 716-645-3391; Fax 716-645-3399; QUAKELINE Info: Phone 716-645-3377) 3. The Earthquake Engineering Research Institute (EERI) was organized in 1949 as a nonprofit corporation with the objective of reducing the impact of earthquakes by means of seismic studies, inspection of earthquake damage, education, and technology transfer, including conferences and the publication of newsletters, reports, technical papers, and conference proceedings. EERI has members in 47 states and 51 foreign countries, including many practicing engineers, architects, and seismologists, as well as university professors and government personnel. Earthquake Spectra, a monthly publication of EERI, contains articles covering a wide range of topics related to earthquakes. EERI has an extensive publication list that also includes videotapes and annotated slide sets showing examples of damage during many past earthquakes. Earthquake Engineering Research Institute 499 14th Street Oakland, CA 94612-1902 (Phone 510-451-0905; Fax 510-451-5411) 4. The Earthquake Engineering Research Center (EERQ is associated with -the University of California at Berkeley. In addition to the extensive shake table testing program, which has been going on for many years and which has produced hundreds of research reports, EERC has an extensive library of earthquake- related materials and a large collection of earthquake slides, and it publishes a newsletter. EERC reports and slide sets are available for sale. The National Information Service for Earthquake Engineering (NISEE) distributes computer software for earthquake engineering and is associated with EERC. NISEE also maintains a computer database of information on earthquake engineering, accessible through Internet. Earthquake Engineering Research Center University of California, Berkeley 1301 South 46th Street Richmond, CA 94804-4698 (Phone 510-231-9554) 5. The Applied Technology Council (ATC) is a nonprofit corporation serving the structural engineering profession. The majority of its, publications are related to technical topics in seismic analysis and design, postearthquake damage evaluations, new technological advances in seismic design, and so on. The specific focus of the organization is to provide a link between academic research and professional practice. ATC sponsors several technical workshops each year. Applied Technology Council 555 Twin Dolphin Drive, Suite 270 Redwood City, CA 94065 (Phone 415-595-1542; Fax 415-593-2320) APPENDIX A NONSTRUCTURAL INVENTORY FORM Facility: Assumed Intensity: Priority Nonstructural Location Quantity Risk ER Estimated Upgrade Cost Notes Item LS PL LF Per Item Subtotal LS (Life Safety) PL (Property Loss) LF (Loss of Function) ER (Engineering Required) L (Low) M (Moderate) H (High) Inventory Form APPENDIX B CHECKLIST OF NONSTRUCTURAL EARTHQUAKE HAZARDS How to Use This Checklist This checklist is intended to be used in surveying buildings to assess whether the nonstructural elements (electrical, mechanical, architectural, and furniture or contents) pose a danger to the building occupants or are likely to cause financial loss or interruption following an earthquake. The questions in this form have been stated in such a way that a "NO" answer indicates there may be a potential problem with the item. Write "Y" for Yes and "N" for No in the box provided. The list may be used in conjunction with the nonstructural inventory form provided in Appendix A. As an example, a line item in the inventory form should be created for each instance where a question in this form is answered "NO". BUILDING UTILITY SYSTEMS EMERGENCY POWER-GENERATING U3. Diesel fuel tank See Example U31 EQUIPMENT Is the tank securely attached to the Emergency power-generating equipment supports? generally consists of the following components: H Are the tank supports braced in both directions? U1. Generator El Is the bracing attached with anchor bolts to concrete walls or foundation pad? Is the emergency generator adequately U Is the foundation large enough to keep secured, especially if mounted on motor the tank from tipping over or sliding? vibration isolation springs? H1 Is the wall strong enough to support the tank? U2. Batteries, battery rack [See Example U2J U4. Fuel line, cooling water lines, exhaust Are the batteries securely attached to the flues battery rack? Is the battery rack cross-braced in both D Are these lines attached with flexible [7 directions? connections that are able to Does the battery rack have anchor bolts accommodate relative movement at secured to a concrete foundation pad? junctions to spring-mounted equipment, [] Is the foundation large enough to keep at building entry and exit points, and at the rack from sliding or tipping? -expansion joints -within the building? B -1 ELECTRICAL EQUIPMENT The emergency power system includes both power-generating equipment and the electrical distribution system: U5. Transformers Are transformers properly anchored: to the floor or wall? U6. Motor Control Center (MCC) Are the motor control centers properly anchored to the floor or wall? X FIRE DETECTION AND SUPPRESSION SYSTEM The fire detection and suppression system may include any or all of the following components: U9. Smoke detectors, fire alarm system, control system for automatic fire doors Are fire and smoke detectors properly mounted? [] Is the control equipment for the fire ''alarm system and automatic fire doors securely anchored? U10. Fire extinguisher or fire hose cabinets [See Example U10 D] Are the fire extinguisher cabinets and/or hose cabinets securely mounted? E] Are the fire extinguishers secured with quick-release straps? Ut1. Fire sprinklers and distribution lines Are the fire sprinkler piping components [Z laterally braced? U7. Electrical switchgear Is the switchgear properly anchored to the floor or wall? U8. Electrical bus ducts and primary cable system [See Example U81 Are electrical cables or conduit able to distort at the connections with the equipment or where they cross seismic D1 joints between buildings? Are the bus ducts or cable conduits laterally braced? (Caution: Only qualified personnel should open access panels on electrical equipment). Is the ceiling braced so the ceilings won't break the sprinkler heads? Are the distribution lines able to accommodate movement where they cross seismic joints between buildings? U12. Fire water pump Dl Is the fire water pump anchored, or is it mounted on vibration isolation springs with additional seismic restraints? U13. Emergency water tank or reservoir Is the water tank or reservoir securely ElD attached to its supports? Are the tank supports braced in both directions? El Are the supports or braces properly anchored to the foundation? U14. Smoke control systems Are the fans properly braced and/or '' anchored? Dl Are fan control centers securely anchored? PROPANE TANKS U16. Shlut-off valve Propane tanks may be used for backup power, Does the system have an automatic, heating, or cooking. These systems, include: earthquake-triggered shut-off valve? If the shut-off is manual, is a wrench U15. Propane tank [See Example U1S] H1 stored within easy reach? . Is the tank securely anchored to the U17. Gas or fuel supply pipe supports? Are the tank supports braced in both Are the supply pipes laterally braced? directions? Are the supports or braces anchored to a D Do the pipes have flexible connections at concrete foundation pad? the tank that are able to accommodate Is the foundation large enough to keep relative movement? the tank from sliding or tipping over? PLUMBING SYSTEM U20. Distribution pumps The plumbing system may include: [7 Are the distribution pumps anchored, or are they mounted on vibration isolation U18. Gas-fired water heater or boiler Springs with additional seismic lateral Are the water heaters or boilers, securely restraints? anchored to the floor or wall? U21. Hot and cold water pipes, hot water Does the gas line have a flexible return, wastewater pipes [See Example U21J connection to the water heater that is able to accommodate movement? [7 Are the pipes laterally braced at reasonable intervals? 1119. Residential water heater [See Examples D Do the pipes have flexible connections to Ul9a and Ul9b boilers or tanks that are able to [Are the water heaters securely anchored D accommodate movement? Are the distribution lines able to to the floor or wall? accommodate movement where they [Does the gas line or electrical conduit cross seismic joints between buildings? have a flexible connection to the water F] Are pipe penetrations through structural heater that is able to accommodate walls or framing members large enough movement? to allow for some seismic movement? Are the pipes free of asbestos insulation that could be damaged by movement in an earthquake? ELEVATORS, ESCALATORS The transport equipment generally includes: U22. Elevator cab Is the elevator cab properly attached to the guide rails? U23. Cables, counterweights, and guide rails (for cable-traction systems) Are the cables installed in such a way that they are protected against misalignment during an earthquake? 7] Are the counterweights properly attached to the guide rails? F] Are the guide rails securely attached to the building? U24. Elevator motor and motor control cabinets Are the motor and motor control cabinets properly anchored? HEATING, VENTILATING, AIR CONDITIONING (HVAC) SYSTEM The HVAC system may include any or all of the following components, depending on the size of the facility: U28. Boilers and furnaces Are boilers and furnaces securely anchored with adequately sized bolts? Are furnaces, and furnace or boiler constructed without using bases, unreinforced masonry? U25. Elevator cab and hydraulic elevator equipment (hydraulic systems) Are the components of the hydraulic system properly anchored? U26. Escalator Is the escalator control equipment securely anchored? U27. People mover (moving walkway) Is the control equipment for the people mover properly anchored? (Caution: The moving parts or components of these systems need to be evaluated by qualified personnel. Inappropriate seismic restraints may compromise the safe operation of these systems.) U29. Chillers [See Examples U29a and U29b] D] Are chillers securely anchored, or are they mounted on vibration isolation springs with added seismic restraints? U30. Heat pumps or heat exchangers F] Are pumps or heat exchangers anchored, or are they mounted on vibration isolation springs with added seismic restraints? U31. Fans, blowers, filters Are fans, blowers, and filters securely anchored, or are they mounted on vibration isolation springs with added seismic restraints? U32. Air compressors [See Example U32J Are air compressors anchored, or are they mounted on vibration isolation springs with added seismic restraints? U33. Roof-mounted HVAC units Are the HVAC units securely anchored, or are they mounted on vibration- limiting springs with added seismic restraints? U34. Wall-mounted room air conditioning units Are the air conditioning units securely mounted to the wall or shelf? MECHANICAL APPENDAGES This category may include the following: U38. Small stacks or residential chimneys [See Example U38] Is the brick chimney braced to the roof? Are stacks, bolted to the supports or foundation by means of anchor bolts of adequate length and double nuts? U35. Suspended room heaters or fans [See Example U35j Are the suspended room heaters, especially gas-fired ones, laterally braced, and are gas-fired heaters fitted with flexible gas connections.? U36. Distribution ducts [See Example U36J Are the distribution ducts laterally braced? Are the distribution ducts able to accommodate movement at locations where they cross seismic joints? U37. Diffusers [See Example U37J Are the air distribution grills or diffusers anchored to adequately supported sheet- metal ducts or to the ceiling grid *or wall? Do the diffusers have positive independent support, such as at least two hanger wires per diffuser? U39. Roof-mounted equpment, vents, or ues Is roof-mounted equipment properly anchored? U40. Solar panels Are the solar panels securely anchored to the roof? Is the piping laterally braced? ARCHITECTURAL ELEMENTS BUILT-IN PARTITIONS These may include elements of many different materials and construction types: Al. Permanent block wall partitions (concrete masonry unit, brick, hollow clay tile) Are block wall partitions reinforced? (Most brick or hollow clay tile walls in pre-1933 California buildings are unreinforced. In other regions, unreinforced masonry elements may be found even in current construction.) CEILINGS AND SOFFITS A3. Ceilings (acoustic tile, gypsumboard, plaster) [See Example ANJ Does the suspended ceiling have adequate diagonal bracing wires? and/or Are decorative ceiling panels latticework securely attached? For plaster ceilings, is the wire mesh or wood lath securely attached to the structural framing above? LIGHTING A5. Suspended overhead lighting, fixed or track lighting [See Examples A5a and A5b] Do the lay-in fluorescent light fixtures have positive support, independent of the ceiling grid, such as at least two diagonally opposite hanger wires per light fixture? Do chandeliers or other hanging fixtures have safety cables to prevent them from impacting each other or a window? Are concrete masonry unit (CMU) partitions detailed to allow sliding at the top? A2. Partial-and full-height stud wall partitions [See Examples A2a and A2b] Are partial-height partitions braced to the structure above the ceiling line? If partitions function as lateral support for tall shelving or cabinets, are these partitions rigidly attached or braced to the structure above the ceiling line? A4. Soffits (stucco, gypsumboard, plaster) Are decorative finishes and/or latticework on beam soffits or beneath exterior eves securely attached, particularly over exits? For stucco soffits, is the wire mesh or wood lath securely attached to the structural framing above? Do pendant or stem light fixtures have safety cables so they will not fall if the fixture sways and breaks the stem connection, or are they braced to prevent swaying? Are spot lights or track lights securely attached to resist seismic shaking? A6. Emergency lighting and exit lights Are emergency lights and exit lights mounted to protect them from falling off shelf supports? DOORS AND EGRESS ROUTES A7. Primary exit doors If exit doors are heavy metal fire doors that might jam if the building racks during an earthquake, is there a crowbar or sledgehammer located near the exit to facilitate emergency exiting? A8. Automatic doors with optical or floor sensors, mechanized roll-up doors Do these doors have a manual override in case of a power outage after an earthquake? A9. Stairways [See Example A9J Do steel stairs in multistory buildings have sliding supports at one end that can accommodate interstory displacements? WINDOWS Note: The term safety glass means tempered, laminated, or wired glass; glass covered with shatter-resistant film; or plastic panels. A12. Glazing [See Example A12] Is it known whether the glazing was designed by an architect/engineer to accommodate lateral movement? Do large windows, especially storefront windows, have safety glass? Have any unreinforced masonry partitions in stairwells been removed, strengthened, or encapsulated? A10. Building utilities and architectural finishes along egress routes (piping, ducts, ceilings, lights, partitions, etc.) Are piping, ducts,. ceilings, lights, partitions, and other elements braced adequately to prevent falling obstructions along egress routes? All. Furniture and/or contents along egress routes (cabinets, shelving, etc.) Are furniture and/or contents along the egress routes sufficiently anchored to prevent objects from obstructing the egress route? Are unanchored furniture and/or contents kept far enough from the exits so they will not slide and obstruct the doors? A13. Overhead glazing or skylights Are transoms (glass panes over doors.) made of safety glass? Are skylights made of safety glass or covered with shatter-resistant film? Are large panes made of safety glass, or is it known whether the glazing assembly was designed by an architect/engineer to accommodate the expected seismic distortion of the surrounding structure? A14. Interior glass or glass block partitions Are the glazed partitions laterally braced to the structure? PERMANENT ORNAMENTATION AND APPENDAGES: EXTERIOR OR INTERIOR A15. Parapets, cornices, veneer or other decoration [See Examples A15a and A15b] [7 Are parapets or cornices reinforced and adequately braced? Do other decorative elements have positive anchorage to the building? Does the veneer have positive anchorage to the building? A16. Freestanding walls or fences (concrete, CMU, brick, or stone) [See Example A16J Is it known whether freestanding walls or fences were designed by an architect/engineer to resist lateral forces? Are CMU walls adequately reinforced with vertical bars set in grout-filled cells and horizontal bars embedded in the Is it known whether CMU walls or mortar joints? fences were built with adequate foundations to prevent them from tipping over in an earthquake? A17. Hanging appendages Are hanging appendages braced or secured with a safety cable? A18. Exterior lighting Are exterior light fixtures properly supported or securely attached to the structure? A19. Flagpoles Are flagpoles securely attached to the structure? A20. Tall sculptures (over about 5 feet) Are heavy or sharply pointed sculptures anchored to prevent overturning during an earthquake? Do hanging sculptures have a safety cable to prevent them from swinging excessively or falling? A21. Heavy signs or exterior billboards [See Example A211 Are exterior signs or billboards adequately braced and anchored? Are interior signs securely attached with positive connections? A22. Clay roof tiles 3 Are clay roof tiles secured to the roof with one nail-and-wire connection per tile? FURNITURE AND CONTENTS COMMUNICATIONS EQUIPMENT Communications and emergency communications systems may include: C1. Radio and short-wave radio equipment Is radio equipment restrained to keep it from sliding off shelving or tabletops? C2. Telephone, cellular phone, and fax equipment Is important equipment restrained to keep it from sliding off shelving or tabletops? Are telephones placed on desktops or counters far enough from the edge that they will not slide and fall off? C3. Public address system Is the public address system restrained to prevent the equipment from sliding and falling off the shelving? C4. Suspended speakers in conference room or auditorium Are sound system speakers in elevated locations anchored to the structure or hung with safety cables? C5. Microwave equipment (antennae, receiver, transmitter, etc.) Is the microwave communications equipment securely braced and/or anchored? C6. Computer networks, data storage Is computer information vital to operations backed up and stored off- site? Is critical -computer equipment securely anchored to supports? Is sensitive computer or communications equipment located out of range of fire sprinkler heads or joints in the sprinkler pipes where they are less prone to water damage if the sprinkler lines break? C7. Wall-mounted televisions or surveillance cameras Are wall-mounted televisions or surveillance cameras in elevated locations securely anchored to support shelves or brackets that are in turn adequately connected to the wall? OFFICE AND COMPUTER EQUIPMENT This category may include a broad range of equipment, such as: C8. Large computer equipment, tape drives [See Example C8]Are computers, tape racks, and associated equipment that is about twice as tall as wide, anchored, tethered, and/or braced? Is heavy computer equipment anchored to the structural floor slab and braced independently of the computer access oors? C9. Computer cabling Is computer cabling long enough to accommodate lateral movement within the building? STORAGE OF RECORDS AND SUPPLIES Storage for files, accounting records, and emergency supplies may include: C12. Bookshelves and library stacks 5 feet or taller [See Examples C12a, C12b, C12c] Are bookshelves properly anchored with brackets to a solid wall or stud, or anchored to the floor? Are bookshelves fitted with edge restraints or elastic cords to keep books from falling? Are large and heavy books located on the lowest shelves? Are rare books given extra protection to prevent falling and water damage? CIO. Desktop computer equipment or printers [See Example C10] Are computer monitors anchored to desktops or computers? Are desktop computers and printers mounted with positive restraint, resting on high-friction rubber pads, or located far enough from the edges of desks and tables to prevent them from sliding and falling in an earthquake? Cl. Computer access floors [See Notes with Example C81 Are computer access floors braced with diagonal steel members, or is it verified that the vertical pedestals are a seismically qualified model, installed in accordance with the manufacturer's recommendations? Do cable openings in the access floor have edge guards to prevent equipment legs from sliding into the openings? C13. Tall vertical or lateral file cabinets [See Example C131 Do the file cabinet drawers or doors latch securely? Are tall file cabinets anchored with wall brackets to a solid wall or stud, anchored to the floor, or bolted to one or more adjacent cabinets to form a more stable configuration, i.e., a larger "footprint"? Are unanchored cabinets located so that they will not fall or slide and block an exit? C14. Tall storage racks or shelving FH Are tall storage racks or shelves securely anchored to the floor or walls? Are heavily loaded racks or shelves braced in both directions? For racks significantly taller than wide, are large anchor bolts used to anchor each leg to a concrete slab? Are breakable items secured to the shelves or racks, or are they stored in stable units (e.g., are they shelved in the original packing boxes, or are small items shrinkwrapped together)? KITCHEN AND LAUNDRY EQUIPMENT These facilities may include any or all of the following items: gas and/or electric stoves and ovens, built-in or countertop microwave ovens, garbage compactors, dishwashers, refrigerators and freezers, clothes washers and dryers, ironing and pressing equipment. C17. Large kitchen or laundry equipment Are all of the these items securely anchored to the floor, wall, or countertop? C18. Gas and/or electric hook-up [See Example CGI1 Are the gas or electric hook-up lines able to accommodate movements at the equipment interface and where they cross seismic joints between buildings? C15. Emergency supply cabinet (water, medicine, food, etc.) Is the cabinet in an accessible location that is not likely to be heavily damaged? Is the cabinet properly braced and anchored, and are the cabinet doors securely latched? C16. Especially valuable and fragile merchandise Are valuable or fragile items. protected against tipping over or falling off shelving or pedestals:? C19. Drawer and cabinet latches (kitchen, laboratory, office, etc.) [See Example CI9J Are the drawers and cabinet doors latched securely, e.g., with special latches or baby-proof hardware that will not fly open in an earthquake? C20. Freestanding wood stove (wood, pellet, or gas-fired) [See Example,C20] Is the stove securely anchored to the hearth or floor framing in a manner that will not conduct heat to any combustible materials? Is the exhaust flue anchored to the stove, are the flue sections, secured together, and is the flue anchored to the wall with some type of thermal radiation shielding? HAZARDOUS MATERIALS Hazardous materials may include: C21. Compressed-gas bottles or cylinders (oxygen, carbon dioxide (CO2), ammonia) [See Example C211 Are gas cylinders tightly secured with one chain near the top and one near the bottom, or are they otherwise restrained? Are the chains or restraints securely anchored to a wall or counter with screws or bolts rather than clamps? C22. Chemical, laboratory, or medical supplies [See Example C221 Are chemical supplies secured with shelf lips several inches high, or are they stored in "egg crate" containers in drawers, so that the containers will not overturn or fall and spill? FURNITURE, INTERIOR DECORATION C25. Potted plants or indoor landscaping resting on shelves above the floor [See Example C28] Are heavy potted plants on file cabinets or tall shelves restrained to prevent falling? C26. Valuable and fragile artwork or decorative vases [See Example C26] Are valuable or fragile items protected against tipping over and/or falling off shelves or pedestals? Are chemicals stored in accordance with manufacturers' recommendations? Are incompatible chemicals stored at an appropriate distance from one another so that they will not mix if the containers are broken? Are the chemicals in each cabinet catalogued properly and marked clearly? Are Material Safety Data Sheets (MSDSs) stored in a location separate from the chemicals? C23. Cabinets for hazardous materials Are cabinets for hazardous materials securely attached to the floor or to a sturdy wall? C24. Asbestos Has asbestos insulation been removed, or has it been encapsulated to reduce the possibility of damage in an earthquake? C27. Freestanding half-height movable partitions [See Example C27] Are freestanding partitions braced or arranged in stable layouts? C28. Miscellaneous furnishings [See Example C28] Are unanchored furnishings located where they cannot slide or overturn to block corridors or doors? C29. Lockers, vending machines Are personal or storage lockers and vending machines anchored and braced, or are they clear of exits? APPENDIX C NONSTRUCTURAL RISK RATINGS Explanation of Risk Ratings The risk ratings that appear in this Appendix are based on the following assumptions: Life Safety (LS) Risk: Risk of being injured by the item. This does not include the overall impact on life safety systems in a building, such as loss of emergency power in a hospital or loss of fire detection capability. These disruptions of service are covered under Function below. Property Loss (PL) Risk: Risk of incurring a repair or replacement cost because of damage to the item. This property loss, as used here, includes the cost of fixing a broken pipe but not the indirect cost of water leakage damage, and includes the cost of repairing a computer but not the loss of business revenue computer downtime might cause. These indirect effects cannot be estimated here on a generic basis. Loss of Function (LF) Risk: Risk that the item will not function because it has been damaged. This includes some consideration of the impact of this loss of function of the component on the operation of an ordinary occupancy building. Not included are off-site functional impacts, such as the loss of function of a piece of equipment because of a city-wide power outage. Outages of power, water, and other utility company or agency services are real problems to consider but are outside the scope of the item-by-item ratings here. Unanchored, unbraced items are assumed. The risk ratings are based on the assumption that the item has been installed without seismic bracing, anchorage, restraint, or allowance for differential movements. In areas of the U.S. where seismic building code provisions have only recently been enforced, this assumption will be generally true. In areas of the western U.S. where seismic codes have been enforced for some time, this assumption may not always be true. Particularly in buildings constructed in the western states since the mid-1970s, some nonstructural items may be anchored or braced, but the assumption of unanchored and unbraced items will still be true for many items on these lists. The item is assumed to be located at or near the ground level, or in a low-rise building. The most common case of a relatively stiff low- rise building with structural walls is presumed in the ratings here. Items such as full-height partitions and glazing are more likely to be damaged in flexible buildings that experience large lateral deformations. Damage to items sensitive to imposed deformation will be greater in buildings or portions of buildings that are more flexible, such as mid-rise and high-rise buildings; flexible frame buildings without significant structural walls; "soft stories" of buildings with structural walls in most stories but with a story, typically the ground story, that is much less laterally stiff because of the absence of walls; the "soft wall" sides of bearing wall buildings where there is little or no solid wall area, such as the face of a typical commercial storefront building. A building of ordinary occupancy is assumed.. Some nonstructural items in special facilities would be rated differently. For example. shelving in an ordinary occupancy building is assumed here, but the same shelving would be rated quite differently with regard to Life Safety risk in a lab, Property Loss risk in a museum, or risk of Loss of Function in a communications center. NONSTRUCTURAL RISK RATINGS SH LS PL LF ER PG UTILITY SYSTEMS EMERGENCY POWER-GENERATING EQUIPMENT U1 Generator Light L L M yes Mod L M H Severe L H H U2 Batteries and battery rack Light L L L yes 30 Mod L H M Severe L H H U3 Diesel fuel tank Light L L L yes 31 Mod H H L Severe H H M U4 Fuel line Light LH L I Mod H H L Severe H H M ELECTRICAL EQUIPMENT U5 Transformers Light L L L yes Mod L L L Severe M M M U6 Motor control center (MCC) Light L L L yes 31 Mod L L L Severe M M M Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= High SH LS PL LF ER PG U7 Electrical switchgear Light L L L yes Mod L L Severe M M M US Electrical bus ducts and primary cable Light L L L yes 32 system Mod L M M Severe M M M FIRE DETECTION AND SUPPRESSION SYSTEM U9 Smoke detectors, fire alarm system, Light L L L control for automatic fire doors Mod L L L Severe L L L U10 Fire extinguisher or fire hose cabinets Light L L L 33 Mod M H L Severe M H L UIl Fire sprinklers and distribution lines Light L M M yes Mod L H H Severe M H H U12 Fire water pump Light L L L 1 yes Mod L L L Severe M M L U13 Emergency water tank or reservoir Light L L L yes Mod M H L Severe H H L Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= high C-3 SH LS PL LF ER_ U14 Smoke control systems Light L L L yes Mod L M L Severe L M L PROPANE TANKS U15 Propane tank Light L L L yes 34 Mod H H M Severe H H M U16 Shut-off valve Light L L L Mod H H M Severe H H M U17 Gas or fuel supply pipe Light L L L Mod H H M Severe H H M PLUMBING SYSTEM U18 Gas-fired water heater or boiler Light L L L yes Mod L L L Severe M M M U19 Residential water heater Light L L L 35, 36 Mod M H L Severe M H L U20 Distribution pumps Light L L L yes Mod L M L Severe L M M Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= High SH L PL LF U21 Hot and cold water pipes, hot water Light L L L yes 37 return, wastewater pipes Mod M M M Severe M M M ELEVATORS, ESCALATORS U22 Elevator cab Light L 'L yesL Mod L M M Severe M M M U23 Cables, counterweights and guide rails Light L L L yes (for cable-traction system) Mod H M Severe H M M U24 Elevator motor and motor control cabinets Light L L L yes| Mod L M M Severe L H M U25 Elevator cab and hydraulic elevator Light L L L yes equipment (hydraulic systems) Mod L M M Severe M M M U26 Escalator Light L L L yes Mod L M L Severe L M L I U27 People mover (noving walkway) Light L L L yes Mod L L L Severe L M L Type of Risk Risk Rating SH= Shaking intensity ER= Engineering required LS= Life safety PL= Property loss L= Low M= Moderate PG= Upgrade detail page number LF= Loss of function H= High I SH LS PL LF I ER PG HEATING, VENTILATING, AIR CONDITIONING (HVAC) SYSTEMU28 Boilers and furnaces Light L L L yes Mod L L L Severe M M M U29 Chillers Light L L L yes 38, Mod L L L Severe L M M U30 Heat pumps or heat exchangers Light L L L yes Mod L L L Severe L M M U31 Fans, blowers, filters Light L L L yes Mod L M L Severe L M M U32 Air compressors Light L L L yes 40 Mod L M L Severe L M M U33 Roof-mounted HVAC units Light L M L yes Mod L M L Severe M H M U34 Wall-mounted room air conditioning units Light L L L Mod H M L Severe H M L U35 Suspended room heaters or fans Light L L L yes 41 Mod H H L Severe H H L Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= High SH LS PL LF ER PG U36 Distribution ducts Light L L L yes 42 Mod L L L Severe M M L U37 Diffusers Light L L L143 Mod H H L Severe H H L MECHANICAL APPENDAGES U38 Small stacks or residential chimneys Light L L L IIZ Mod M M L Severe H M M U39 Roof-mounted equipment, vents or flues Light L L L yes Mod L M L Severe M M M U40 Solar panels Light L L L yes Mod L L L Severe M M L Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= High I SH LS PL LF I ER PG ARCHITECTURAL ELEMENTS PARTITIONS AND CEILINGS Al Permanent block wall partitions (CMU, Light L L L yes brick, hollow clay tile) Mod H H H Severe H H H A2 Partial-and full-height stud wall partitions Light L L L yes 45, Mod M M H Severe, M H H A3 Ceilings (acoustic tile, gypsumboard, Light L L L yes 47 plaster) Mod M M M Severe H H H A4 Soffits (stucco, gypsumboard, plaster) Light L L L Mod M M M Severe H H H LIGHTING AS Suspended overhead lighting, fixed or Light L L L |48, track lighting 49 Mod H L L Severe H M M A6 Emergency lighting and exit lights Light L L L Mod M L L Severe H M L Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M = Moderate PG= Upgrade detail page number LF= Loss of function H= High SH LS PL LF ER P DOORS AND EGRESS ROUTES A7 Primary exit doors Light L L L yes| Mod L L Severe M M M A8 Automatic doors with optical or floor Light L L L yes sensors,, mechanized roll-up doors Mod L i L Severe M M M A9 Stairways Light L L L yes |50 Mod H M L Severe H M H A10 Building utilities and architectural finishes Light L L L yes along egress routes (ceilings, lights, Mod H M L partitions, etc.) I Severe H M L All Furniture and/or contents along egress Light L L L routes (cabinets, shelving, etc.) Mod H M L Severe H M LM Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function 11= High C -9 WINDOWS A12 Glazing Light L L L yes 51 Mod 1 M L Severe H M M A13 Overhead glazing or skylights Light L L L yes _ Mod H M L Severe H M M SH LS PL LF ER P A14 Interior glass or glass block partitions Light L L L yes Mod M M Severe H H M PERMANENT ORNAMENTATION AND APPENDAGES: INTERIOR OR EXTERIOR A15 Parapets, cornices, veneer or other Light M M L yes 52, decoration Mod H H L Severe H H L A16 Freestanding walls or fences (concrete, Light L L L yes CMU, brick, or stone Mod L L L Severe H H M A17 Hanging appendages Light L L L yes Mod H H L Severe H H M A18 Exterior lighting Light L L L Mod M L L Severe M M M A19 Flagpoles Light L L L yes Mod L L L Severe M M L A20 Tall sculptures (over 5 feet) Light L L L yes Mod M M L Severe H H L Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= High SJ Ls PL LF ER PG A21 Heavy signs or exterior billboards Light L L L yes 55 Mod H H L Severe H H L A22 Clay roof tiles Light L L L yes Mod L M L Severe M H M FURNITURE AND CONTENTS COMMUNICATIONS EQUIPMENT C1 Radio and short-wave radio equipment Light L L L Mod L H H Severe L H H C2 Telephone, cellular phone and fax Light L L L equipment Mod L H M Severe L H M C3 Public address system Light L L L Mod L H L Severe L H _ C4 Suspended speakers in conference room or Light L L L yes auditorium Mod M M L Severe H H L CS Microwave equipment (antennae, receiver, Light L L L yes transmitter, etc.) Mod L M L Severe,M H M Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PG= Upgrade 'detail page number PL= Property loss LF= Loss of function M= Moderate H= High SH LS PL LF ER C6 Computer networks, data storage Light L L L Mod L M H Severe L H H C7 Wall-mounted televisions or surveillance Light L L L yes Mod H H L cameras Severe H H L OFFICE AND COMPUTER EQUIPMENT C8 Large computer equipment, tape drives Light L L L yes 56 Mod L M M Severe M H M C9 Computer cabling Light L L L Mod L L L Severe L L L C1O Desktop computers or office equipment Light L L L 57 Mod L H M Severe L H M C11 Computer access floors Light L L L 56 Mod L L M Severe L M M STORAGE OF RECORDS AND SUPPLIES C12 Book shelves, library stacks (over 5 feet) Light L L L yes 58, 59, 60 Mod H M M Severe H M M Type of Risk Risk Rating SH= Shaking intensity ER= Engineering required PG= Upgrade detail page number LS= Life safety PL= Property loss LF= Loss of function L= Low M= Moderate H= High S S LF ER PG C13 Tall vertical or lateral file cabinets Light L L L yes 61 Mod M M M Severe H M M_ C14 Tall storage racks or shelving Light L L L Mod H M M Severe M M L C15 Emergency supply cabinet (water, Light L L L medicine, food, etc.) Mod L L L Severe M M M C16 Especially valuable and fragile Light L M L merchandise Mod L H L Severe L H L KITCHEN AND LAUNDRY EQUIPMENT C17 Large kitchen or laundry equipment Light L L L Mod M M L Severe H M M C18 Gas and/or electric hook-up Light L L L 62 Mod M H H Severe H H H C19 Drawer and cabinet latches (kitchen, Light L L L 63 laboratory, office, etc) Mod L L L Severe L M M Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= Eligible SH LS PL LF ER PG C20 Freestanding wood stove (wood, pellet, or gas-fired) Light Mod L L L L L L 64 Severe M M M HAZARDOUS MATERIALS C21 Compressed-gas bottles or cylinders (oxygen, C0 2 , ammonia, etc.) Light Mod L M L M L L 65 Severe H M M C22 Chemical, laboratory, or medical supplies Light L L L yes 66 Mod H M L Severe H M M C23 Cabinets for hazardous materials Light L L L yes Mod H M H Severe H M H C24 Asbestos Light L M M Mod L H H Severe L H H FURNITURE, INTERIOR DECORATION C25 Potted plants or indoor landscaping resting on shelves above the floor Light Mod L L L L L L 69 Severe M L L C26 Valuable and fragile artwork or decorative Light L L L 67 vases Mod L H L Severe L H L Type of Risk Risk Rating SH= Shaking intensity ER= Engineering required PG= Upgrade detail page number LS= Life safety PL= Property loss LF= Loss of function L= Low M= Moderate H= High C-14 SH -PL LF ER P C27 Freestanding half-height movable Light L L L 63 partitions Severe M M M C28 Miscellaneous furnishings Light L L L Mod L M L Severe L M L C29 Lockers, vending machines Light L L L Mod H M L Severe H M L Type of Risk Risk Rating SH= Shaking intensity LS= Life safety L= Low ER= Engineering required PL= Property loss M= Moderate PG= Upgrade detail page number LF= Loss of function H= High U. S. GOVEHNMENT PRINTING OFCE: 2002-71i6S2&968243